Numerical Study on Fluid-Structure Interaction in a Patient-Specific Abdominal Aortic Aneurysm for Evaluating Wall Heterogeneity and Material Model Effects on its Rupture

被引:12
|
作者
Mesri, Y. [1 ,2 ]
Niazmand, H. [1 ,2 ]
Deyranlou, A. [1 ,2 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Mech Engn, Mashhad, Iran
[2] Ferdowsi Univ Mashhad, Res Ctr Biomed Engn, Mashhad, Iran
关键词
Abdominal aortic aneurysm; Fluid-structure interaction; Material model; Wall thickness; INTRALUMINAL THROMBUS; BLOOD-FLOW; STRESS-ANALYSIS; RISK; BIOMECHANICS; IDENTIFICATION; PREDICTION; MECHANICS; DIAMETER; GEOMETRY;
D O I
10.18869/acadpub.jafm.73.243.27678
中图分类号
O414.1 [热力学];
学科分类号
摘要
Abdominal Aortic Aneurysm (AAA) is one of the main cardiovascular diseases, which threats human's health while it appears, develops and in crucial cases ruptures and leads to hemorrhage. In the current work, we aim to investigate numerically the transient blood flow in a patient-specific AAA model, while effects of wall compliance is considered by employing the fluid-structure interaction method. The AAA model is reconstructed from acquired CT angiographic data of a patient diagnosed with AAA and an intraluminal thrombus (ILT). For the comparison purposes two different material models, i.e. isotropic and anisotropic are considered. Additionally, to have a better estimation, wall thickness variability is compared with simpler uniform wall thickness model. In this study Navier-Stokes equations along with elastodynamics equation are coupled through Arbitrary Lagrangian-Eulerian formulation method and solved numerically. Findings demonstrate that the isotropic material model with uniform wall thickness significantly underestimates wall stresses as compared to the anisotropic material model with variable wall thickness. Indeed, results emphasize that considering vessel wall as an anisotropic, heterogeneous (variable thickness) structure estimates much higher wall stresses comparing with isotropic, uniform thickness model. Therefore, given realistic vessel wall structure and the fact that the anisotropic, variable wall thickness model predicts higher wall stresses, it could be a more reliable model to give an accurate estimation to physicians to diagnose the stage of a disease and choosing an appropriate therapeutic procedure.
引用
收藏
页码:1699 / 1709
页数:11
相关论文
共 50 条
  • [1] Influence of wall thickness on the rupture risk of a patient-specific cerebral aneurysm: A fluid-structure interaction study
    Valeti, Chanikya
    Bolem, Srinivas
    Alagan, Azhaganmaadevi K.
    Sudhir, B. J.
    Kannath, Santhosh K.
    Akhade, Bhushan
    Matham, Gowtham
    Krishnakumar, K.
    Patnaik, B. S. V.
    PHYSICS OF FLUIDS, 2024, 36 (09)
  • [2] A patient-specific computational model of fluid-structure interaction in abdominal aortic aneurysms
    Wolters, BJBM
    Rutten, MCM
    Schurink, GWH
    Kose, U
    de Hart, J
    van de Vosse, FN
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (10) : 871 - 883
  • [3] Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft
    Molony, David S.
    Callanan, Anthony
    Kavanagh, Eamon G.
    Walsh, Michael T.
    McGloughlin, Tim M.
    BIOMEDICAL ENGINEERING ONLINE, 2009, 8 : 24
  • [4] Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft
    David S Molony
    Anthony Callanan
    Eamon G Kavanagh
    Michael T Walsh
    Tim M McGloughlin
    BioMedical Engineering OnLine, 8
  • [5] Integrated particle image velocimetry and fluid-structure interaction analysis for patient-specific abdominal aortic aneurysm studies
    Ozcan, Can
    Kocaturk, Ozgur
    Islak, Civan
    Ozturk, Cengizhan
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [6] Fluid-structure interaction simulations of patient-specific aortic dissection
    Baeumler, Kathrin
    Vedula, Vijay
    Sailer, Anna M.
    Seo, Jongmin
    Chiu, Peter
    Mistelbauer, Gabriel
    Chan, Frandics P.
    Fischbein, Michael P.
    Marsden, Alison L.
    Fleischmann, Dominik
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2020, 19 (05) : 1607 - 1628
  • [7] Risk of rupture of the cerebral aneurysm in relation to traumatic brain injury using a patient-specific fluid-structure interaction model
    Razaghi, Reza
    Biglari, Hasan
    Karimi, Alireza
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2019, 176 : 9 - 16
  • [8] Fully coupled vs. partially coupled fluid-structure interaction methods for patient-specific abdominal aortic aneurysm biomechanics
    Scotti, Christine M.
    Finol, Ender A.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 527 - 528
  • [9] A numerical study of fluid-structure coupled effect of abdominal aortic aneurysm
    Cong, Yingbo
    Wang, Liya
    Liu, Xiao
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S245 - S255
  • [10] Evaluating Design of Abdominal Aortic Aneurysm Endografts in a Patient-Specific Model Using Computational Fluid Dynamics
    Segalova, Polina A.
    Xiong, Guanglei
    Rao, K. T. Venkateswara
    Zarins, Christopher K.
    Taylor, Charles A.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2011, 5 (04):