Evaluation of lung volumetry using dynamic three-dimensional magnetic resonance imaging

被引:69
|
作者
Plathow, C [1 ]
Schoebinger, M
Fink, C
Ley, S
Puderbach, M
Eichinger, M
Bock, M
Meinzer, HP
Kauczor, HU
机构
[1] German Canc Res Ctr, Dept Radiol, INF 280, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Med & Biol Informat, D-69120 Heidelberg, Germany
[3] German Canc Res Ctr, Dept Med Phys Radiol, D-69120 Heidelberg, Germany
关键词
lung motion; volumetry; dynamic 3D MRI; respiration; spirometry; view sharing;
D O I
10.1097/00004424-200503000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: We sought to investigate lung volume and surface measurements during the breathing cycle using dynamic three-dimensional magnetic resonance imaging (3D MRI). Materials and Methods: Breathing cycles of 20 healthy volunteers were examined using a 2D trueFISP sequence (3 images/second) in combination with a model and segmented 3D FLASH sequence (1 image/second) MR images using view sharing. Segmentation was performed semiautomatically using an interactive region growing technique. Vital capacity (VC) was calculated from MRI using the model (2D) and counting the voxels (3D) and was compared with spirometry. Results: VC from spirometry was 4.9 +/- 0.9 L, 4.4 +/- 1.2 L from 2D MRI measurement, and 4.7 +/- 0.9 L for 3D MRI. Using the 3D technique, correlation to spirometry was higher than using the 2D technique (r > 0.95 vs. r > 0.83). Using the 3D technique, split lung volumes and lung surface could be calculated. There was a significant difference between the left and right lung volume in expiration (P < 0.05). Conclusions: Dynamic 3D MRI is a noninvasive tool to evaluate split lung volumes and lung surfaces during the breathing cycle with a high correlation to spirometry.
引用
收藏
页码:173 / 179
页数:7
相关论文
共 50 条
  • [1] Reliability of interactive three-dimensional brain volumetry using MP-RAGE magnetic resonance imaging
    Julin, P
    Melin, T
    Andersen, C
    Isberg, B
    Svensson, L
    Wahlund, LO
    PSYCHIATRY RESEARCH-NEUROIMAGING, 1997, 76 (01) : 41 - 49
  • [2] EVALUATION OF HIP INSTABILITY IN THE NORMAL AND DYSPLASTIC HIPS USING DYNAMIC THREE-DIMENSIONAL MAGNETIC RESONANCE IMAGING
    Akiyama, K.
    Sakai, T.
    Koyanagi, J.
    Yoshikawa, H.
    Sugamoto, K.
    OSTEOARTHRITIS AND CARTILAGE, 2010, 18 : S191 - S191
  • [3] Analysis of Three-Dimensional In Vivo Knee Kinematics Using Dynamic Magnetic Resonance Imaging
    Ma, C. Benjamin
    Lee, Keh-yang
    Schrumpf, Mark A.
    Majumdar, Sharmila
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2005, 15 (01) : 57 - 63
  • [4] Controlled drug release from an ocular implant: An evaluation using dynamic three-dimensional magnetic resonance imaging
    Kim, H
    Robinson, MR
    Lizak, MJ
    Tansey, G
    Lutz, RJ
    Yuan, P
    Wang, NS
    Csaky, KG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (08) : 2722 - 2731
  • [5] Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
    Klimes, Filip
    Voskrebenzev, Andreas
    Wacker, Frank
    Vogel-Claussen, Jens
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (208):
  • [6] Three-dimensional magnetic resonance based volumetry in multiple system atrophy
    Schocke, M
    Seppi, K
    Kremser, C
    Jaschke, W
    Poewe, W
    Wenning, G
    MOVEMENT DISORDERS, 2002, 17 : S262 - S262
  • [7] Three-dimensional magnetic resonance imaging for groundwater
    Legchenko, A.
    Descloitres, M.
    Vincent, C.
    Guyard, H.
    Garambois, S.
    Chalikakis, K.
    Ezersky, M.
    NEW JOURNAL OF PHYSICS, 2011, 13
  • [8] Fetal lung volumetry by three-dimensional ultrasound
    Pohls, UG
    Rempen, A
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 11 (01) : 6 - 12
  • [9] Investigation of resonance strategies of high pitch singing sopranos using dynamic three-dimensional magnetic resonance imaging
    Koeberlein, Marie
    Birkholz, Peter
    Burdumy, Michael
    Richter, Bernhard
    Burk, Fabian
    Traser, Louisa
    Echternach, Matthias
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 150 (06): : 4191 - 4202
  • [10] Fetal lung volume: three-dimensional ultrasonography compared with magnetic resonance imaging
    Gerards, F. A.
    Twisk, J. W. R.
    Bakker, M.
    Barkhof, F.
    Van Vugt, J. M. G.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (05) : 533 - 536