Attenuation map reconstruction using topology constrained labeling

被引:0
|
作者
Kudo, H [1 ]
Nakamura, H
机构
[1] Univ Tsukuba, Inst Informat Sci & Elect, Tsukuba, Ibaraki 3058573, Japan
[2] Univ Tsukuba, Doctoral Program Engn, Tsukuba, Ibaraki 3058573, Japan
关键词
image reconstruction; SPECT; PET; attenuation map; stochastic relaxation;
D O I
10.1002/ecjb.10179
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to derive a quantitative reconstructed image in various types of emission CT (ECT), such as SPECT and PET, it is necessary to examine the gamma ray attenuation coefficient distribution inside the body, called the attenuation map, by transmission CT (TCT), and to apply attenuation correction. This paper proposes a new method in which the attenuation map is reconstructed from the incomplete TCT projection data or ECT projection data. The conventional attenuation map reconstruction method is performed, assuming that each pixel of the attenuation map takes a continuous value. In the proposed method, in contrast, the attenuation map is reconstructed by region segmentation in which the pixel value takes only discrete values. The problem is formulated as a labeling problem in which the label image minimizing the energy function is to be determined. In order to avoid local minima, the solution is derived by stochastic relaxation. In the conventional formulation of image region segmentation, however, the search space for the solution is too wide, and it is difficult to derive an accurate attenuation map if the measured data are incomplete. Consequently, this paper proposes topology constrained labeling, in which topology constraints, that is, a priori information on the topology (the number of regions and the connection relations among the regions) of the attenuation map to which the region segmentation is applied, are used, and (he solution search space is constrained. Simulation experiments, as well as an experiment using the actual PET data, were performed, and the effectiveness of the topology constrained labeling has been demonstrated. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:31 / 41
页数:11
相关论文
共 50 条
  • [1] Reconstruction of Attenuation Coefficient Using Amplitude Distribution Map
    Wu, Nan
    Zhao, Shu
    Dong, Feng
    [J]. PROCEEDINGS OF THE 39TH CHINESE CONTROL CONFERENCE, 2020, : 2792 - 2797
  • [2] Reconstruction of attenuation map using discrete consistency conditions
    Bronnikov, AV
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 451 - 462
  • [3] Reconstruction of attenuation map in SPECT imaging
    Bronnikov, AV
    [J]. PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 852 - 852
  • [4] APPROXIMATE RECONSTRUCTION OF ATTENUATION MAP IN SPECT IMAGING
    BRONNIKOV, AV
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (05) : 1483 - 1488
  • [5] Joint reconstruction of activity and attenuation map using LM SPECT emission data
    Jha, Abhinav K.
    Clarkson, Eric
    Kupinski, Matthew A.
    Barrett, Harrison H.
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [6] Crack Shape Reconstruction from ECT Using Topology Constrained Optimization (TOPCSA) Algorithms
    Calvano, Flavio
    Caturano, Gennaro
    Cavaccini, Giovanni
    Rubinacci, Guglielmo
    Tamburrino, Antonello
    Ventre, Salvatore
    [J]. ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XIII), 2010, 33 : 230 - 237
  • [7] Methods of attenuation map reconstruction for colimated line sources
    Sitek, A
    Celler, A
    Harrop, R
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 918 - 918
  • [8] Towards using scattered PET emission data for reconstruction of attenuation map in PET/MRI
    Yannick Berker
    Volkmar Schulz
    [J]. EJNMMI Physics, 1 (Suppl 1)
  • [9] Limited view CT reconstruction via constrained metric labeling
    Singh, Vikas
    Dinu, Petru M.
    Mukherjee, Lopamudra
    Xu, Jinhui
    Hoffmann, Kenneth R.
    [J]. 2007 IEEE 11TH INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS 1-6, 2007, : 2480 - +
  • [10] SPECT attenuation correction based on combined transmission-emission reconstruction of the attenuation map
    Bronnikov, AV
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3484 - 3486