Sonographic estimation of needle depth for cervical epidural blocks

被引:16
|
作者
Kim, Soo Hwan [1 ]
Lee, Kang Hun [1 ]
Yoon, Kyung Bong [1 ]
Park, Woo Young [1 ]
Yoon, Duck-Mi [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Anesthesia & Pain Med, Seoul 120752, South Korea
来源
ANESTHESIA AND ANALGESIA | 2008年 / 106卷 / 05期
关键词
D O I
10.1213/ane.0b013e318168b6a8
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Cervical epidural steroid injections are often used to treat acute and chronic pain syndromes involving the face, neck, and upper extremities. Ultrasound has evolved as a valuable tool for performing neuraxial blocks, providing useful prepuncture information on the structure. Our goal was to evaluate the accuracy and precision of ultrasound by comparing skin to dura distance from ultrasound with the actual skin to epidural depth. METHODS: We enrolled 50 patients undergoing cervical epidural blocks at the pain clinic. Ultrasound images with transverse and longitudinal median views of the C6/7 area were taken. The epidural needle was inserted, reproducing the direction of the ultrasound beam on the longitudinal median view. Measured distances from skin to dura on each ultrasound view were compared with the actual needle depth. Additionally, we examined ultrasound visibility, the number of puncture attempts, land any complications related to the procedure. RESULTS: Concordance correlation coefficients between the measured distances on ultrasound and actual needle depth were 0.9272 and 0.9268 on transverse and longitudinal median view, respectively. The cervical epidural block was successfully performed on 48 patients (96%). There were two incidents (4%) of dural puncture. No bloody taps, postprocedure complications, or hemodynamic instability related to cervical epidural blocks occurred. CONCLUSIONS: Ultrasound provides very accurate information on the skin to dura distance for epidural blocks in the cervical spine. Knowledge of skin to dura distance and a preview of spinal anatomy before puncture can more safely identify the epidural space..
引用
收藏
页码:1542 / 1547
页数:6
相关论文
共 50 条
  • [1] Sonographic measurement of needle insertion depth in paravertebral blocks in women
    Pusch, F
    Wildling, E
    Klimscha, W
    Weinstabl, C
    BRITISH JOURNAL OF ANAESTHESIA, 2000, 85 (06) : 841 - 843
  • [2] Cervical Epidural Depth: Correlation Between Cervical MRI Measurements of the Skin- toCervical Epidural Space and the Actual Needle Depth During Interlaminar Cervical Epidural Injections
    Algrain, Haitham
    Liu, Alison
    Singh, Sarabdeep
    Vu, To-Nhu
    Cohen, Steven P.
    PAIN MEDICINE, 2018, 19 (05) : 1015 - 1022
  • [3] Cervical Epidural Depth: Correlation Between Needle Angle, Cervical Anatomy, and Body Surface Area
    Fujinaka, Michael K.
    Lawson, Erin F.
    Schulteis, Gery
    Wallace, Mark S.
    PAIN MEDICINE, 2012, 13 (05) : 665 - 669
  • [4] Letter to the Editor Regarding a Recent Article: Cervical Epidural Depth: Correlation Between Cervical MRI Measurements of the Skin-to-Cervical Epidural Space and the Actual Needle Depth During Interlaminar Cervical Epidural Injections
    Landers, Milton H.
    PAIN MEDICINE, 2019, 20 (09) : 1845 - 1848
  • [5] Letter to the Editor Regarding a Recent Article: Cervical Epidural Depth: Correlation Between Cervical MRI Measurements of the Skin-to-Cervical Epidural Space and the Actual Needle Depth During Interlaminar Cervical Epidural Injections Response
    Algrain, Haitham
    PAIN MEDICINE, 2019, 20 (09) : 1848 - 1849
  • [6] Calculation improves the estimation of needle depth from skin to thoracic epidural space in infants
    Fideler, Frank
    Grasshoff, Christian
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2019, 36 (03) : 235 - 237
  • [7] Fluoroscopically Guided Extraforaminal Cervical Nerve Root Blocks: Analysis of Epidural Flow of the Injectate with Respect to Needle Tip Position
    Shipley, Kyle
    Riew, K. Daniel
    Gilula, Louis A.
    GLOBAL SPINE JOURNAL, 2014, 4 (01) : 7 - 12
  • [8] PROPER NEEDLE SIZE FOR PERFORMING CERVICAL EPIDURAL INJECTIONS - REPLY
    JACKSON, K
    RAUCK, RL
    ANESTHESIOLOGY, 1991, 75 (01) : 166 - 166
  • [9] Optimal Needle Entry Angle for Cervical Transforaminal Epidural Injections
    Chen, Boqing
    Rispoli, Leia
    Stitik, Todd P.
    Foye, Patrick M.
    Georgy, John S.
    PAIN PHYSICIAN, 2014, 17 (02) : 139 - 144
  • [10] Randomized comparison between epidural waveform analysis through the needle versus the catheter for thoracic epidural blocks
    Tangjitbampenbun, Amornrat
    Layera, Sebastian
    Arnuntasupakul, Vanlapa
    Apinyachon, Worapot
    Venegas, Karen
    Godoy, Jaime
    Aliste, Julian
    Bravo, Daniela
    Blanch, Alonso
    Webar, Javier
    Saadawi, Mohammed
    Owen, Andrew
    Finlayson, Roderick J.
    Tran, De Q.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2019, 44 (08) : 800 - 804