Development and performance of a filter radiometer monitor system for integrating sphere sources

被引:6
|
作者
Ding, Leibo [1 ]
Kowalewski, Matthew G. [2 ]
Cooper, John W. [1 ]
Smith, Gilbert R. [1 ]
Barnes, Robert A. [3 ]
Waluschka, Eugene [4 ]
Butler, James J. [4 ]
机构
[1] SigmaSpace Corp, Lanham, MD 20706 USA
[2] Univ Space Res Org, Columbia, MD 21044 USA
[3] Sci Applicat Int Corp, Beltsville, MD 20705 USA
[4] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
关键词
integrating sphere; calibration; stability; radiometer; EARTH OBSERVING SYSTEM; CALIBRATION;
D O I
10.1117/1.3646532
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The NASA Goddard Space Flight Center (GSFC) Radiometric Calibration Laboratory (RCL) maintains several large integrating sphere sources covering the visible to the shortwave infrared wavelength range. Two critical, functional requirements of an integrating sphere source are short- and long-term operational stability and repeatability. Monitoring the source is essential in determining the origin of systemic errors, thus increasing confidence in source performance and quantifying repeatability. If monitor data falls outside the established parameters, this could be an indication that the source requires maintenance or recalibration against the National Institute of Science and Technology irradiance standard. The GSFC RCL has developed a Filter Radiometer Monitoring System (FRMS) to continuously monitor the performance of its integrating sphere calibration sources in the 400 to 2400 nm region. Sphere output change mechanisms include lamp aging, coating (e.g., BaSO(4)) deterioration, and ambient water vapor level. The FRMS wavelength bands are selected to quantify changes caused by these mechanisms. The FRMS design and operation are presented, as well as data from monitoring four of the RCL's integrating sphere sources. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3646532]
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A filter radiometer monitoring system for integrating sphere sources
    Marketon, J
    Abel, P
    Butler, JJ
    Smith, GR
    Cooper, JW
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES IV, 2000, 4169 : 260 - 267
  • [2] Comparison of Lamp and Detector-based Integrating Sphere Radiance Calibrations Using the NASA GSFC Filter Radiometer Monitoring System (FRMS)
    Lalanne, Elaine N.
    Butler, James J.
    Ding, Leibo
    Cooper, John
    Kelley, Nathan E.
    EARTH OBSERVING SYSTEMS XXVII, 2022, 12232
  • [3] Performance of an embedded SAW sensor for filter bed monitor and the development of a wireless monitoring prototype system
    Dominguez, DD
    McGill, RA
    Chung, R
    Nguyen, V
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1998, : 602 - 607
  • [4] An integrating sphere radiometer as a solution for high power calibrations in fibre optics
    Carrasco-Sanz, Ana
    Rodriguez-Barrios, Felix
    Corredera, Pedro
    Martin-Lopez, Sonia
    Gonzalez-Herraez, Miguel
    Hernanz, Maria Luisa
    METROLOGIA, 2006, 43 (02) : S145 - S150
  • [5] Private life of an integrating sphere: the radiant homogeneity of the Descent Imager-Spectral Radiometer calibration sphere
    Rizk, B
    APPLIED OPTICS, 2001, 40 (13) : 2095 - 2101
  • [6] Private life of an integrating sphere: The radiant homogeneity of the descent imager-spectral radiometer calibration sphere
    Rizk, Bashar
    Applied Optics, 2001, 40 (13): : 2095 - 2101
  • [7] Ground-monitor radiometer system for vicarious calibration
    Thome, K
    Czapla-Myers, J
    Biggar, S
    IMAGING SPECTROMETRY X, 2004, 5546 : 223 - 232
  • [8] Illumination from extended sources computed by the theory of the integrating sphere
    Benford, F
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1940, 30 (01) : 33 - 40
  • [9] POSSIBLE SOURCES OF ERROR IN USE OF INTEGRATING-SPHERE REFLECTOMETERS
    NIVERT, LJ
    KNEISSL, GJ
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1969, 59 (04) : 517 - &
  • [10] Characterization of spectral irradiance system based on a filter radiometer
    Lima, M. S.
    Silva, T. F.
    Duarte, I.
    Correa, J. S.
    Viana, D.
    Sousa, W. A.
    Almeida, G. B.
    Couceiro, I. B.
    8TH BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2015), 2016, 733