Blood transfer devices for malaria rapid diagnostic tests: evaluation of accuracy, safety and ease of use

被引:14
|
作者
Hopkins, Heidi [1 ]
Oyibo, Wellington [2 ]
Luchavez, Jennifer [3 ]
Lorraine Mationg, Mary [3 ]
Asiimwe, Caroline [1 ]
Albertini, Audrey [4 ]
Gonzalez, Iveth J. [4 ]
Gatton, Michelle L. [5 ]
Bell, David [4 ,6 ]
机构
[1] Fdn Innovat New Diagnost, Kampala, Uganda
[2] Univ Lagos, Coll Med, Dept Med Microbiol & Parasitol, Lagos, Nigeria
[3] Res Inst Trop Med, Alabang, Muntinlupa, Philippines
[4] Fdn Innovat New Diagnost, Geneva, Switzerland
[5] Queensland Inst Med Res, Brisbane, Qld 4006, Australia
[6] WHO, Global Malaria Programme, CH-1211 Geneva, Switzerland
来源
MALARIA JOURNAL | 2011年 / 10卷
基金
澳大利亚国家健康与医学研究理事会;
关键词
PARASIGHT(TM)-F TEST; HEALTH-WORKERS; REMOTE AREA;
D O I
10.1186/1475-2875-10-30
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Malaria rapid diagnostic tests (RDTs) are increasingly used by remote health personnel with minimal training in laboratory techniques. RDTs must, therefore, be as simple, safe and reliable as possible. Transfer of blood from the patient to the RDT is critical to safety and accuracy, and poses a significant challenge to many users. Blood transfer devices were evaluated for accuracy and precision of volume transferred, safety and ease of use, to identify the most appropriate devices for use with RDTs in routine clinical care. Methods: Five devices, a loop, straw-pipette, calibrated pipette, glass capillary tube, and a new inverted cup device, were evaluated in Nigeria, the Philippines and Uganda. The 227 participating health workers used each device to transfer blood from a simulated finger-prick site to filter paper. For each transfer, the number of attempts required to collect and deposit blood and any spilling of blood during transfer were recorded. Perceptions of ease of use and safety of each device were recorded for each participant. Blood volume transferred was calculated from the area of blood spots deposited on filter paper. Results: The overall mean volumes transferred by devices differed significantly from the target volume of 5 microliters (p < 0.001). The inverted cup (4.6 microliters) most closely approximated the target volume. The glass capillary was excluded from volume analysis as the estimation method used is not compatible with this device. The calibrated pipette accounted for the largest proportion of blood exposures (23/225, 10%); exposures ranged from 2% to 6% for the other four devices. The inverted cup was considered easiest to use in blood collection (206/ 226, 91%); the straw-pipette and calibrated pipette were rated lowest (143/225 [ 64%] and 135/225 [60%] respectively). Overall, the inverted cup was the most preferred device (72%, 163/227), followed by the loop (61%, 138/227). Conclusions: The performance of blood transfer devices varied in this evaluation of accuracy, blood safety, ease of use, and user preference. The inverted cup design achieved the highest overall performance, while the loop also performed well. These findings have relevance for any point-of-care diagnostics that require blood sampling.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Blood transfer devices for malaria rapid diagnostic tests: evaluation of accuracy, safety and ease of use
    Heidi Hopkins
    Wellington Oyibo
    Jennifer Luchavez
    Mary Lorraine Mationg
    Caroline Asiimwe
    Audrey Albertini
    Iveth J González
    Michelle L Gatton
    David Bell
    [J]. Malaria Journal, 10
  • [2] Accuracy, Ease of Use, Safety, and Acceptability of a 23-μL Conical Cup Blood Transfer Device for Use with Rapid Diagnostic Tests
    Incardona, Sandra
    Kyabayinze, Daniel J.
    Bell, David
    Ndawula, Bbale
    Kanyago, Marvis C.
    Mwancha-Kwasa, Magoma C.
    Gonzalez, Iveth J.
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2018, 99 (03): : 797 - 804
  • [3] Evaluation of rapid diagnostic tests: Malaria
    Bell D.
    Peeling R.W.
    [J]. Nature Reviews Microbiology, 2006, 4 (Suppl 9) : S34 - S38
  • [4] Evaluation of rapid diagnostic tests: malaria
    Bell, David
    Peeling, Rosanna W.
    [J]. NATURE REVIEWS MICROBIOLOGY, 2006, : S34 - S40
  • [5] An assessment of various blood collection and transfer methods used for malaria rapid diagnostic tests
    Luchavez, Jennifer
    Lintag, M. Eichelle
    Coll-Black, Mary
    Baik, Fred
    Bell, David
    [J]. MALARIA JOURNAL, 2007, 6 (1)
  • [6] An assessment of various blood collection and transfer methods used for malaria rapid diagnostic tests
    Jennifer Luchavez
    Ma Eichelle Lintag
    Mary Coll-Black
    Fred Baik
    David Bell
    [J]. Malaria Journal, 6
  • [7] Use of rapid diagnostic tests for diagnosis of malaria in the UK
    Chilton, D.
    Malik, A. N. J.
    Armstrong, M.
    Kettelhut, M.
    Parker-Williams, J.
    Chiodini, P. L.
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 2006, 59 (08) : 862 - 866
  • [8] The use of rapid diagnostic tests for measuring malaria transmission
    Bjorkman, A.
    [J]. TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2011, 16 : 12 - 12
  • [9] Evaluation of rapid diagnostic tests for malaria in Swedish travellers
    Bronner, Ulf
    Karlsson, Lillemor
    Evengard, Birgitta
    [J]. APMIS, 2011, 119 (02) : 88 - 92
  • [10] Economic evaluation of rapid diagnostic tests in malaria treatment
    Faye, Adama
    Ndiaye, Papa
    Diagne-Camara, Maty
    Badiane, Ousseynou
    Wone, Issa
    Diongue, Mayassine
    Seck, Ibrahima
    Dia, Anta Tat
    Dia, Amadou Lamine
    [J]. SANTE PUBLIQUE, 2010, 22 (06): : 617 - 623