Long-term measurements of equilibrium factor with electrochemically etched CR-39 SSNTD

被引:1
|
作者
Ng, F. M. F. [1 ]
Nikezic, D. [1 ]
Yu, K. N. [1 ]
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon Tong, Hong Kong, Peoples R China
关键词
radon progeny concentration; equilibrium factor; CR-39;
D O I
10.1016/j.nimb.2007.04.309
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recently, our group proposed a method (proxy equilibrium factor method) using a bare LR 115 detector for long-term monitoring of the equilibrium factor. Due to the presence of an upper alpha-particle energy threshold for track formation in the LR 115 detector, the partial sensitivities to Rn-222, Po-218 and (214)po were the same, which made possible measurements of a proxy equilibrium factor F, that was well correlated with the equilibrium factor. In the present work, the method is extended to CR-39 detectors which have better-controlled etching properties but do not have an upper energy threshold. An exposed bare CR-39 detector is first pre-etched in 6.25 N NaOH solution at 70 degrees C for 6 h, and then etched electrochemically in a 6.25 N NaOH solution with ac voltage of 400 V (peak to peak) and 5 kHz applied across the detectors for I It at room temperature. Under these conditions, for tracks corresponding to incident angles larger than or equal to 50 degrees, the treeing efficiency is 0% and 100% for incident energies smaller than and larger than 4 MeV, respectively. A simple method is then proposed to obtain the total number of tracks formed below the upper energy threshold of 4 MeV, from which the proxy equilibrium factor method can apply. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:279 / 283
页数:5
相关论文
共 50 条
  • [1] A method for calculation of the neutron response function of an electrochemically etched CR-39 SSNTD up to 65 MeV
    Fenyvesi, A
    Greenhouse, NA
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D394 - D394
  • [2] Response of electrochemically etched CR-39 detectors to protons
    Dörschel, B
    Hermsdorf, D
    Kadner, K
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 137 - 140
  • [3] TRACK-SIZE DISTRIBUTION OF ELECTROCHEMICALLY ETCHED CR-39
    AZIMIGARAKANI, D
    BOSCHUNG, M
    WERNLI, C
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 443 - 444
  • [4] FURTHER INVESTIGATION ON ELECTROCHEMICALLY ETCHED CR-39 NEUTRON DETECTORS
    AZIMIGARAKANI, D
    TOMMASINO, L
    TORRI, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 309 - 312
  • [5] ADDITIONAL RESULTS WITH ELECTROCHEMICALLY ETCHED CR-39 NEUTRON DOSIMETERS
    ZAPPAROLI, G
    TOMMASINO, L
    DJEFFAL, S
    MAIORANA, A
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 675 - 678
  • [6] Bulk and track etch properties of CR-39 SSNTD etched in NaOH/ethanol
    Chan, K. F.
    Ng, F. M. F.
    Nikezic, D.
    Yu, K. N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 284 - 289
  • [7] NEUTRON SENSITIVITY OF CR-39 SSNTD
    BIRKHOLZ, W
    WINKLER, C
    BAUMBACH, H
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 453 - 456
  • [8] THE NEUTRON ENERGY AND ANGULAR RESPONSE OF ELECTROCHEMICALLY ETCHED CR-39 DOSIMETERS
    CROSS, WG
    ARNEJA, A
    KIM, JL
    RADIATION PROTECTION DOSIMETRY, 1987, 20 (1-2) : 49 - 55
  • [9] Angular response to neutrons of the electrochemically etched CR-39 with different radiators
    Bednar, J
    Turek, K
    Spurny, F
    RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 153 - 156
  • [10] FAST-NEUTRON SPECTROMETRY WITH ELECTROCHEMICALLY ETCHED CR-39 DETECTORS
    MATIULLAH
    KUDO, K
    KHAN, S
    KHAN, HA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 505 - 506