Minimum Steel for Reinforced Concrete Slabs

被引:0
|
作者
Narayanan, Subramanian [1 ]
机构
[1] 23 Napa Valley Rd, Gaithersburg, MD 20878 USA
关键词
ACI; 318; IS; 456; Minimum steel; RC slabs; Shrinkage; Temperature;
D O I
10.1061/(ASCE)SC.1943-5576.0000618
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Reinforced concrete slabs are often exposed to rain and radiation from the sun, in addition to normal loads, and hence have to be provided with at least the minimum shrinkage and temperature reinforcement. Shrinkage and temperature reinforcement has traditionally been specified as a certain percentage of the cross-sectional area (about 0.12%-0.18%), which is often empirical. Moreover, this was specified when M20-M25 concrete and reinforcements of Grade Fe 415 were used, which have since been found to be inadequate by practicing engineers. Some researchers have found that the reinforcement prescribed in codes has to be increased considerably to avoid cracks due to shrinkage and temperature effects. Hence, a formula for minimum reinforcement has been developed for slabs, similar to that for beams, which provides consistent safety against collapse due to cracking. It takes into account factors that may affect the behavior of these slabs, such as concrete and steel strength and the ratio of depth to effective depth. (C) 2021 American Society of Civil Engineers.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [1] Design of reinforced concrete slabs and beams for minimum cost
    El-Rayyes, MS
    KUWAIT JOURNAL OF SCIENCE & ENGINEERING, 2000, 27 (02): : 225 - 245
  • [2] Behaviour of reinforced concrete slabs with steel fibers
    Baarimah, A. O.
    Mohsin, S. M. Syed
    GLOBAL CONGRESS ON CONSTRUCTION, MATERIAL AND STRUCTURAL ENGINEERING 2017 (GCOMSE2017), 2017, 271
  • [3] Steel fibre reinforced concrete flat slabs
    Gossla, Ulrich
    Beton- und Stahlbetonbau, 2006, 101 (02) : 94 - 102
  • [4] Concrete Slabs Reinforced with FRP or Steel Reinforcements
    Razzaq, Zia
    Dabbagh, Mohamed A. E.
    Sirjani, Mojtaba B.
    Prabhakaran, Ram
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2009, 28 (09) : 1111 - 1121
  • [5] Reinforced concrete slabs with stainless steel waste
    Perez Gonzalez, Jorge Alberto
    REVISTA INGENIERIA DE CONSTRUCCION, 2008, 23 (02): : 72 - 81
  • [6] Minimum reinforcement volumes for reinforced concrete slabs by the strip method
    Datta, T.K.
    Ahmad, M.Z.
    Proceedings of the Institution of Civil Engineers (London). Part 1 - Design & Construction, 1988, 85 pt 2 : 457 - 467
  • [8] Design of steel fibre reinforced concrete slabs on grade
    Silfwerbrand, J
    FIFTH RILEM SYMPOSIUM ON FIBRE-REINFORCED CONCRETES (FRC), 2000, 15 : 305 - 314
  • [9] SUSTAINABILITY ANALYSIS OF STEEL FIBRE REINFORCED CONCRETE SLABS
    Blanco, A.
    De La Fuente, A.
    Aguado, A.
    II INTERNATIONAL CONFERENCE ON CONCRETE SUSTAINABILITY - ICCS16, 2016, : 850 - 861
  • [10] Prognosis of the deflection of reinforced slabs of steel fibre concrete
    Mertzsch, Olaf
    Hammer, Christoph
    Wolf, Thomas