Evaluation of the BD Phoenix Automated Microbiology System for identification and antimicrobial susceptibility testing of common clinical isolates

被引:8
|
作者
Liu, ZK [1 ]
Ling, TK [1 ]
Cheng, AF [1 ]
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Microbiol, Hong Kong, Hong Kong, Peoples R China
关键词
BD Phoenix Automated Microbiology System; API system; microbroth dilution method;
D O I
10.1159/000085744
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the accuracy and reliability of the BD Phoenix Automated Microbiology System for identification ( ID) and antimicrobial susceptibility testing ( AST) of Gram- positive and Gram- negative isolates. Materials and Methods: The ID of 291 Gram- negative and 158 Gram- positive clinical isolates were evaluated by the system. The AST of 252 Gram- negative and 151 Gram-positive isolates with correct ID were then evaluated. The results were compared with those of the API ID system and the microbroth dilution method. All discrepant results were repeated for verification. Results: Over 90% Gram- negative and Gram- positive isolates were correctly identified to species or genus level by the Phoenix system. The minimum inhibitory concentration agreement rates between the Phonenix and the microbroth dilution methods within 8 1 dilution ranged from 87.3 to 97.6% for Gram- negative isolates, and from 50 to 100% for Gram- positive isolates. For Gram- positive isolates, vancomycin had significant low minimum inhibitory concentration agreement rates. Conclusions: Overall, the results indicate that the Phoenix system is a reliable system. It could provide accurate ID and AST results for routine clinical laboratories. Copyright (C) 2005 S. Karger AG, Basel.
引用
收藏
页码:250 / 254
页数:5
相关论文
共 50 条
  • [1] Evaluation of the BD phoenix automated microbiology system for identification and antimicrobial susceptibility testing of Enterobacteriaceae
    Carroll, Karen C.
    Glanz, Brian D.
    Borek, Anita P.
    Burger, Chad
    Bhally, Hasan S.
    Henciak, Susan
    Flayhart, Diane
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (10) : 3506 - 3509
  • [2] Evaluation of the BD Phoenix automated microbiology system for identification and antimicrobial susceptibility testing of staphylococci and enterococci
    Carroll, Karen C.
    Borek, Anita P.
    Burger, Chad
    Glanz, Brian
    Bhally, Hasan
    Henciak, Susan
    Flayhart, Diane C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (06) : 2072 - 2077
  • [3] Evaluation of the BD Phoenix M50 Automated Microbiology System for Antimicrobial Susceptibility Testing with Clinical Isolates in Korea
    Hong, Jun Sung
    Kim, Dokyun
    Kang, Da Young
    Park, Byeol Yi
    Yang, SunMi
    Yoon, Eun-Jung
    Lee, Hyukmin
    Jeong, Seok Hoon
    MICROBIAL DRUG RESISTANCE, 2019, 25 (08) : 1142 - 1148
  • [4] Evaluation of the BD Phoenix Automated Identification and Susceptibility Testing System in Clinical Microbiology Laboratory Practice
    E. Stefaniuk
    A. Baraniak
    M. Gniadkowski
    W. Hryniewicz
    European Journal of Clinical Microbiology and Infectious Diseases , 2003, 22 : 479 - 485
  • [5] Evaluation of the BD Phoenix automated identification and susceptibility testing system in clinical microbiology laboratory practice
    Stefaniuk, E
    Baraniak, A
    Gniadkowski, M
    Hryniewicz, W
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2003, 22 (08) : 479 - 485
  • [6] Identification and antimicrobial susceptibility testing of Staphylococcus vitulinus by the BD Phoenix automated microbiology system
    Cirkovic, Ivana
    Hauschild, Tomasz
    Jezek, Petr
    Dimitrijevic, Vladimir
    Vukovic, Dragana
    Stepanovic, Srdjan
    CURRENT MICROBIOLOGY, 2008, 57 (02) : 158 - 160
  • [7] Identification and Antimicrobial Susceptibility Testing of Staphylococcus vitulinus by the BD Phoenix Automated Microbiology System
    Ivana Ćirković
    Tomasz Hauschild
    Petr Ježek
    Vladimir Dimitrijević
    Dragana Vuković
    Srdjan Stepanović
    Current Microbiology, 2008, 57 : 158 - 160
  • [8] Performance evaluation of the BD phoenix automated microbiology system in meropenem susceptibility testing of clinical Pseudomonas aeruginosa isolates
    Bayramoglu, Gulcin
    Acuner, Ibrahim C.
    Sinirtas, Melda
    Gedikoglu, Suna
    Durupinar, Belma
    SAUDI MEDICAL JOURNAL, 2006, 27 (12) : 1921 - 1923
  • [9] Multicenter evaluation of the BD phoenix automated microbiology system for antimicrobial susceptibility testing of Streptococcus species
    Richter, Sandra S.
    Howard, Wanita J.
    Weinstein, Melvin P.
    Bruckner, David A.
    Hindler, Janet F.
    Saubolle, Michael
    Doern, Gary V.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (09) : 2863 - 2871
  • [10] Evaluation of the BD Phoenix Automated Microbiology System SMIC/ID panel for identification and antimicrobial susceptibility testing of Streptococcus spp
    Hirakata, Y
    Matsuda, J
    Nakano, M
    Hayashi, T
    Tozaka, S
    Takezawa, T
    Takahashi, H
    Higashiyama, Y
    Miyazaki, Y
    Kamihira, S
    Kohno, S
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2005, 53 (03) : 169 - 173