Smart catheter flow sensor for real-time continuous regional cerebral blood flow monitoring

被引:17
|
作者
Li, Chunyan [1 ]
Wu, Pei-Ming [1 ]
Hartings, Jed A. [2 ]
Wu, Zhizhen [3 ]
Ahn, Chong H. [3 ]
LeDoux, David [4 ]
Shutter, Lori A. [2 ]
Narayan, Raj K. [1 ,5 ]
机构
[1] Feinstein Inst Med Res, Cushing Neuromonitoring Lab, Manhasset, NY 11030 USA
[2] Univ Cincinnati, Coll Med, Dept Neurosurg, Cincinnati, OH 45219 USA
[3] Univ Cincinnati, Microsyst & BioMEMS Lab, Cincinnati, OH 45221 USA
[4] N Shore Univ Hosp, Neurosurg Intens Care Unit, Manhasset, NY 11030 USA
[5] Hofstra N Shore LIJ Sch Med, Dept Neurosurg, Hempstead, NY 11549 USA
关键词
BRAIN; TUBE;
D O I
10.1063/1.3669705
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present a smart catheter flow sensor for real-time, continuous, and quantitative measurement of regional cerebral blood flow using in situ temperature and thermal conductivity compensation. The flow sensor operates in a constant-temperature mode and employs a periodic heating and cooling technique. This approach ensures zero drift and provides highly reliable data with microelectromechanical system-based thin film sensors. The developed flow sensor has a sensitivity of 0.973 mV/ml/100 g/min in the range from 0 to 160 ml/100 g/min with a linear correlation coefficient of R-2 = 0.9953. It achieves a resolution of 0.25 ml/100 g/min and an accuracy better than 5 ml/100 g/min. (C) 2011 American Institute of Physics. [doi:10.1063/1.3669705]
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Smart Catheter Flow Sensor for Continuous Regional Cerebral Blood Flow Monitoring
    Li, Chunyan
    Wu, Pei-Ming
    Wu, Zhizhen
    Ahn, Chong H.
    Hartings, Jed A.
    Narayan, Raj K.
    [J]. 2011 IEEE SENSORS, 2011, : 1417 - 1420
  • [2] PORTABLE REAL-TIME ANALYSIS SYSTEM FOR REGIONAL CEREBRAL BLOOD-FLOW
    TIERNAN, T
    ENTINE, G
    STUMP, DA
    PROUGH, DS
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 698 - 702
  • [3] Toward real-time continuous brain glucose and oxygen monitoring with a smart catheter
    Li, Chunyan
    Ahn, Chong H.
    Shutter, Lori A.
    Narayan, Raj K.
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 25 (01): : 173 - 178
  • [4] Real-time and continuous monitoring of myocardial blood flow using a thermal diffusion method
    Kamiya, H
    Watanabe, G
    Saito, T
    Doi, T
    Tomita, S
    Ohtake, H
    Kanamori, T
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (04) : 748 - 752
  • [5] Real-time monitoring of spinal cord blood flow with a novel sensor mounted on a cerebrospinal fluid drainage catheter in an animal model
    Hayatsu, Yukihiro
    Kawamoto, Shunsuke
    Matsunaga, Tadao
    Haga, Yoichi
    Saiki, Yoshikatsu
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (04): : 1726 - 1731
  • [6] Intraoperative real-time and continuous cerebral blood flow visualization with laser speckle contrast imaging
    Miller, David R.
    Ashour, Ramsey
    Sullender, Colin T.
    Dunn, Andrew K.
    [J]. CLINICAL AND TRANSLATIONAL NEUROPHOTONICS 2022, 2022, 11945
  • [7] CONTINUOUS REGIONAL CEREBRAL BLOOD-FLOW MONITORING IN ACUTE CRANIOCEREBRAL TRAUMA
    DICKMAN, CA
    CARTER, LP
    BALDWIN, HZ
    HARRINGTON, T
    TALLMAN, D
    [J]. NEUROSURGERY, 1991, 28 (03) : 467 - 472
  • [8] Continuous regional cerebral blood flow monitoring in the neurosurgical intensive care unit
    Lee, SC
    Chen, JF
    Lee, ST
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2005, 12 (05) : 520 - 523
  • [9] CONTINUOUS MONITORING OF THE REGIONAL CEREBRAL BLOOD-FLOW OF THE EPILEPTIC FOCUS IN CATS
    TANAKA, T
    KUNIMOTO, M
    TANAKA, S
    YONEMASU, Y
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1987, 67 (03): : P70 - P70
  • [10] REAL-TIME MONITORING OF MITOCHONDRIAL FUNCTION AND CEREBRAL BLOOD FLOW FOLLOWING FOCAL ISCHEMIA IN RATS
    Livnat, Amir
    Tolmasov, Michael
    Barbiro-Michaely, Efrat
    Mayevsky, Avraham
    [J]. JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2008, 1 (01) : 63 - 69