Optical polarimetry for noninvasive glucose sensing enabled by Sagnac interferometry

被引:21
|
作者
Winkler, Amy M. [1 ]
Bonnema, Garret T. [1 ]
Barton, Jennifer K. [2 ]
机构
[1] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Biomed Engn, Tucson, AZ 85721 USA
关键词
CORNEAL BIREFRINGENCE; AQUEOUS-HUMOR; HUMAN-EYE;
D O I
10.1364/AO.50.002719
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical polarimetry is used in pharmaceutical drug testing and quality control for saccharide-containing products (juice, honey). More recently, it has been proposed as a method for noninvasive glucose sensing for diabetic patients. Sagnac interferometry is commonly used in optical gyroscopes, measuring minute Doppler shifts resulting from mechanical rotation. In this work, we demonstrate that Sagnac interferometers are also sensitive to optical rotation, or the rotation of linearly polarized light, and are therefore useful in optical polarimetry. Results from simulation and experiment show that Sagnac interferometers are advantageous in optical polarimetry as they are insensitive to net linear birefringence and alignment of polarization components. (C) 2011 Optical Society of America
引用
收藏
页码:2719 / 2731
页数:13
相关论文
共 50 条
  • [1] Optical polarimetry applied to the development of a noninvasive in vivo glucose monitor
    Cameron, BD
    Baba, JS
    Coté, GL
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS V, 2000, 3923 : 66 - 77
  • [2] The use of optical polarimetry as a noninvasive in vivo physiological glucose monitor
    Webb, Anthony J.
    Cameron, Brent D.
    OPTICAL DIAGNOSTICS AND SENSING XI: TOWARD POINT-OF-CARE DIAGNOSTICS AND DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE III, 2011, 7906
  • [3] Advances in noninvasive glucose sensing enabled by photonics, acoustics, and microwaves
    Tajima T.
    Nakamura M.
    Tanaka Y.
    Seyama M.
    International Journal of Automation Technology, 2018, 12 (01) : 64 - 72
  • [4] Mueller matrix polarimetry approach for noninvasive glucose sensing with absorbance and anisotropic parameters on fingertips
    Huang, Po-Ling
    Lo, Yu-Lung
    Chen, Yu-Ren
    Liu, Chih-Yi
    JOURNAL OF BIOPHOTONICS, 2024, 17 (09)
  • [5] Noninvasive glucose sensing
    Arnold, MA
    Small, GW
    ANALYTICAL CHEMISTRY, 2005, 77 (17) : 5429 - 5439
  • [6] Preliminary Accuracy Analysis of a Noninvasive Optical Glucose Sensing Prototype
    Geiser, Luke
    Leung, Ho Man Colman
    Berget, Cari
    Gong, Chengyue
    Liu, Qiang
    Zhou, Xia
    Forlenza, Gregory P.
    DIABETES, 2023, 72
  • [7] High-speed dual-wavelength optical polarimetry for glucose sensing
    Grunden, Daniel T.
    Pirnstill, Casey W.
    Cote, Gerard L.
    OPTICAL DIAGNOSTICS AND SENSING XIV: TOWARD POINT-OF-CARE DIAGNOSTICS, 2014, 8951
  • [8] Extra wideband polarimetry, interferometry and polarimetric interferometry in synthetic aperture remote sensing
    Boerner, WM
    Yamaguchi, Y
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2000, E83B (09) : 1906 - 1915
  • [9] Noninvasive Glucose Sensing In Vivo
    Leung, Ho Man Colman
    Forlenza, Gregory P.
    Prioleau, Temiloluwa O.
    Zhou, Xia
    SENSORS, 2023, 23 (16)
  • [10] Optical polarimetry probe for glucose monitoring
    Kang, Heesung
    Bae, Youngwoo
    Jung, Byungjo
    2007 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1-4, 2007, : 559 - +