Exploring the Divergence Range for Stereopsis Maintenance With a Computer-Simulated Troposcope in Patients With Intermittent Exotropia

被引:4
|
作者
Huang, Chu-Hsuan [1 ]
Wang, Ai-Hou [2 ,3 ]
Hu, Fung-Rong [1 ,2 ]
Tsai, Tzu-Hsun [1 ,2 ,4 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Ophthalmol, 12F,7 Zhongshan S Rd, Taipei 100, Taiwan
[2] Natl Taiwan Univ, Dept Ophthalmol, Coll Med, Taipei, Taiwan
[3] Cathay Gen Hosp, Dept Ophthalmol, Taipei, Taiwan
[4] Natl Taiwan Univ, Coll Med, Grad Inst Clin Med, Taipei, Taiwan
关键词
intermittent exotropia; suppression; stereopsis; divergence; PRIMARY VISUAL-CORTEX; STRABISMIC SUPPRESSION; PRESCHOOL-CHILDREN; STEREOACUITY; DISTANCE; VISION;
D O I
10.1167/iovs.16-19779
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate whether sensory input or motor signal of the extraocular muscle is the main activator of suppression in human intermittent exotropia (X(T)). METHODS. A case-control study was performed. Ten subjects with X(T) and 10 control participants were enrolled. The divergence range between both eyes when binocular vision was maintained was measured by using stereotests with a self-written computer program mimicking a troposcope. The break point, defined as the deviation angle at which stereopsis broke during eye deviation, was compared between the experimental and control groups by using a t test. RESULTS. The median near deviation angle in the experimental group was 42.5 prism diopters (PD) (mean, 44.5 +/- 10.82 PD). The mean break point was 40.45 +/- 10.79 PD in the X(T) group and 26.86 +/- 2.62 PD in the control group (P = 0.003). The mean ratio of the break point to the near deviation angle was 0.92 +/- 0.23 in the X(T) group, with the ratio close to 1 in 7 of 10 subjects. CONCLUSIONS. Binocular vision can be maintained if similar images are projected onto corresponding retinas during the tropic phase of X(T). The antidiplopic mechanism in X(T) patients (i.e., suppression) is evoked by sensory input from binocular rivalry rather than by motor signal of the extraocular muscle.
引用
收藏
页码:4493 / 4497
页数:5
相关论文
共 15 条
  • [1] Evaluation of dynamic stereopsis in intermittent exotropia patients
    Jing Zhong
    Da-Ming Deng
    Zi-Dong Chen
    Jin-Rong Li
    Jun-Peng Yuan
    Lei Feng
    Ai-Hou Wang
    Min-Bin Yu
    [J]. International Journal of Ophthalmology, 2019, (01) : 83 - 88
  • [2] Evaluation of dynamic stereopsis in intermittent exotropia patients
    Zhong, Jing
    Deng, Da-Ming
    Chen, Zi-Dong
    Li, Jin-Rong
    Yuan, Jun-Peng
    Feng, Lei
    Wang, Ai-Hou
    Yu, Min-Bin
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (01) : 83 - 88
  • [3] THE RANGE OF MOTION OF A COMPUTER-SIMULATED WRIST
    DEV, P
    LENDRUM, D
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (08) : 542 - 542
  • [4] A Novel Dynamic Random-dot Stereopsis Strategy for Assessing the Dynamic Stereopsis in Intermittent Exotropia Patients
    Jing, Zhong
    Chen, Zidong
    Li, Jinrong
    Yuan, Junpeng
    Deng, Daming
    Yu, Minbin
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [5] COMPUTER-SIMULATED PATIENTS FOR ENHANCING CLINICAL EXPERIENCES
    LEVITT, H
    SLOSBERG, R
    [J]. EDUCATIONAL TECHNOLOGY, 1978, 18 (06) : 42 - 43
  • [6] CHEMICAL SHORT-RANGE ORDER IN COMPUTER-SIMULATED METALLIC GLASSES
    HARRIS, R
    LEWIS, LJ
    [J]. JOURNAL OF PHYSICS F-METAL PHYSICS, 1983, 13 (07): : 1359 - 1367
  • [7] A new program package for investigation of medium-range order in computer-simulated solids
    Rybicki, J
    Bergmanski, G
    Mancini, G
    [J]. JOURNAL OF NON-CRYSTALLINE SOLIDS, 2001, 293 : 758 - 763
  • [8] CHEMICAL SHORT-RANGE ORDER IN THE COMPUTER-SIMULATED TRANSITION-METAL METALLOID ALLOYS
    JEZIERSKI, A
    [J]. PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 1986, 135 (02): : 467 - 473
  • [9] THE VALIDITY OF A COMPUTER-SIMULATED BREAKFAST COOKING TASK AS A PREDICTOR OF DISABILITY IN PATIENTS WITH SCHIZOPHRENIA
    Parlar, Melissa
    Heinrichs, R. Walter
    Vaz, Stephanie McDermid
    Cole, Emily
    [J]. SCHIZOPHRENIA BULLETIN, 2017, 43 : S124 - S124
  • [10] Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients
    Frush, DP
    Slack, CC
    Hollingsworth, CL
    Bisset, GS
    Donnelly, LF
    Hsieh, J
    Lavin-Wensell, T
    Mayo, JR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) : 1107 - 1113