Removal of taste and odor from drinking water: performance evaluation and upgrade options for the treatment plants in Istanbul

被引:2
|
作者
Fakioglu, Malhun [1 ]
Karpuzcu, Mahmut Ekrem [1 ]
Toroz, Ismail [1 ]
Yildiz, Fatih [2 ]
Ozturk, Izzet [1 ]
机构
[1] Istanbul Tekn Univ Istanbul, Insaat Fak, Cevre Muhendisligi Bolumu, Istanbul, Turkey
[2] Su Aritma Daire Baskanligi, Istanbul Su & Kanalizasyon Idaresi, Istanbul, Turkey
关键词
Drinking water treatment; Full scale treatment; 2-MIB; Geosmin; ACTIVATED CARBON; GEOSMIN; 2-METHYLISOBORNEOL; CYANOBACTERIA; BROMATE; MIB;
D O I
10.5505/pajes.2019.78949
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Istanbul, one of the most crowded cities in the world with approximately 15 million population, has various surface water sources. The city is recently having taste and odor problem originating from 2-MIB and Geosmin due to algal blooms occurring in these water sources. The aim of this study is not only to evaluate the removal of taste and odor compounds in water treatment plants, but also to improve the efficiency of existing removal processes along with suggesting new processes that are effective for the removal of these compounds. In this context; measurements were evaluated along with performing the experiments for the alternative chemicals and a detailed cost analysis were made for the proposed new processes. In 5 main water treatment plants of ISKI, removal efficiencies with ozonation were 2-14% for TOC, 35-62% for 2-MIB and 34-52% for Geosmin, between the years 2013-2016. According to the experimental results, applying 10 mg/L powdered activated carbon with alum provided the highest removal efficiency for 2-MIB (50%) and Geosmin (66%) while TOC removal was higher with FeCl3 (38%). UV254 removal was within the range of 60-70% for all three coagulants. Turbidity removal was quite higher with FeCl3 compared to PACl. Finally, the applicability of peroxone process to the existing plants were evaluated. According to the calculations, unit cost for a water treatment plant with a 100,000 m(3)/day capacity was found as 0.027 $/m(3) (0.14 TL/m(3)) for the peroxone system. This cost is 20% higher than a sole ozonation system.
引用
收藏
页码:505 / 512
页数:8
相关论文
共 50 条
  • [1] Drinking water treatment options for taste and odor control
    Hargesheimer, EE
    Watson, SB
    WATER RESEARCH, 1996, 30 (06) : 1423 - 1430
  • [2] Treatment of taste and odor causing substances in drinking water
    Kim, Y
    Lee, Y
    Gee, CS
    Choi, E
    WATER SCIENCE AND TECHNOLOGY, 1997, 35 (08) : 29 - 36
  • [3] Evaluation of algae related taste and odor problem in drinking water
    Fakioglu, Malhun
    Karpuzcu, Mahmut Ekrem
    Ozturk, Izzet
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2018, 24 (06): : 1141 - 1156
  • [4] Evaluation of phosphorus removal from a lake by two drinking water treatment plants
    Huang, Yifeng
    Mackenzie, Alec
    Meteer, Laura
    Hofmann, Ron
    ENVIRONMENTAL TECHNOLOGY, 2020, 41 (07) : 863 - 869
  • [5] Design and evaluation of hydraulic baffled-channel PAC contactor for taste and odor removal from drinking water supplies
    Kim, Young-Ik
    Bae, Byung-Uk
    WATER RESEARCH, 2007, 41 (10) : 2256 - 2264
  • [6] Jar tests for evaluation of atrazine removal at drinking water treatment plants
    Zhang, TC
    Emary, SC
    ENVIRONMENTAL ENGINEERING SCIENCE, 1999, 16 (06) : 417 - 432
  • [8] Co-Occurrence of Microcystins and Taste-and-Odor Compounds in Drinking Water Source and Their Removal in a Full-Scale Drinking Water Treatment Plant
    Shang, Lixia
    Feng, Muhua
    Xu, Xiangen
    Liu, Feifei
    Ke, Fan
    Li, Wenchao
    TOXINS, 2018, 10 (01):
  • [10] Comparative microbial metagenomic analysis of drinking water plants and wastewater treatment plants in Istanbul
    Demirci, Mehmet
    Cubuk, Cankut
    Dasdemir, Ferhat
    Saribas, Abdulkerim Suat
    Balcioglu, Esra Billur
    Ozbey, Dogukan
    Yorulmaz, Dogu
    Hanci, Tugba Olmez
    Basa, Safak
    Kocazeybek, Bekir Sami
    FRONTIERS IN MICROBIOLOGY, 2025, 16