Diagnostic accuracy of coronary computed tomography angiography for the evaluation of obstructive coronary artery disease in patients referred for transcatheter aortic valve implantation: a systematic review and meta-analysis
被引:20
|
作者:
Gatti, Marco
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
Gatti, Marco
[1
]
Gallone, Guglielmo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Div Cardiol, Dept Med Sci, Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
Gallone, Guglielmo
[2
]
Poggi, Vittoria
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
Poggi, Vittoria
[1
]
Bruno, Francesco
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Div Cardiol, Dept Med Sci, Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
Bruno, Francesco
[2
]
Serafini, Alessandro
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
Serafini, Alessandro
[1
]
Depaoli, Alessandro
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
Depaoli, Alessandro
[1
]
De Filippo, Ovidio
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Div Cardiol, Dept Med Sci, Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
De Filippo, Ovidio
[2
]
Conrotto, Federico
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Div Cardiol, Dept Med Sci, Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
Conrotto, Federico
[2
]
Darvizeh, Fatemeh
论文数: 0引用数: 0
h-index: 0
机构:
Univ Vita Salute San Raffaele, Sch Med, I-20121 Milan, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
Darvizeh, Fatemeh
[3
]
Faletti, Riccardo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
Faletti, Riccardo
[1
]
De Ferrari, Gaetano Maria
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Div Cardiol, Dept Med Sci, Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
De Ferrari, Gaetano Maria
[2
]
Fonio, Paolo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
Fonio, Paolo
[1
]
D'Ascenzo, Fabrizio
论文数: 0引用数: 0
h-index: 0
机构:
Univ Turin, Div Cardiol, Dept Med Sci, Turin, ItalyUniv Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
D'Ascenzo, Fabrizio
[2
]
机构:
[1] Univ Turin, Dept Surg Sci, Radiol Unit, Via Genova 3, I-10126 Turin, Italy
[2] Univ Turin, Div Cardiol, Dept Med Sci, Turin, Italy
[3] Univ Vita Salute San Raffaele, Sch Med, I-20121 Milan, Italy
Objective To evaluate the diagnostic accuracy of coronary computed tomography angiography (CCTA) for the evaluation of obstructive coronary artery disease (CAD) in patients referred for transcatheter aortic valve implantation (TAVI). Methods EMBASE, PubMed/MEDLINE, and CENTRAL were searched for studies reporting accuracy of CCTA for the evaluation of obstructive CAD compared with invasive coronary angiography (ICA) as the reference standard. QUADAS-2 tool was used to assess the risk of bias. A bivariate random effects model was used to analyze, pool, and plot the diagnostic performance measurements across studies. Pooled sensitivity, specificity, positive ( + LR) and negative (-LR) likelihood ratio, diagnostic odds ratio (DOR), and hierarchical summary ROC curve (HSROC) were evaluated. Prospero registration number: CRD42021252527. Results Fourteen studies (2533 patients) were included. In the intention-to-diagnose patient-level analysis, sensitivity and specificity for CCTA were 97% (95% CI: 94-98%) and 68% (95% CI: 56-68%), respectively, and + LR and -LR were 3.0 (95% CI: 2.1-4.3) and 0.05 (95% CI: 0.03 - 0.09), with DOR equal to 60 (95% CI: 30-121). The area under the HSROC curve was 0.96 (95% CI: 0.94-0.98). No significant difference in sensitivity was found between single-heartbeat and other CT scanners (96% (95% CI: 90 - 99%) vs. 97% (95% CI: 94-98%) respectively; p = 0.37), whereas the specificity of single-heartbeat scanners was higher (82% (95% CI: 66-92%) vs. 60% (95% CI: 46 - 72%) respectively; p < 0.0001). Routine CCTA in the pre-TAVI workup could save 41% (95% CI: 34 - 47%) of ICAs if a disease prevalence of 40% is assumed. Conclusions CCTA proved an excellent diagnostic accuracy for assessing obstructive CAD in patients referred for TAVI; the use of single-heartbeat CT scanners can further improve these findings.