Anodic stripping voltammetric determination of copper (II) in wastewaters using a carbon paste electrode modified with chitosan

被引:18
|
作者
Janegitz, Bruno Campos [1 ]
Marcolino, Luiz Humberto, Jr. [1 ]
Fatibello-Filho, Orlando [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, BR-13560 Sao Carlos, SP, Brazil
来源
QUIMICA NOVA | 2007年 / 30卷 / 07期
关键词
chitosan; copper(II); stripping analysis;
D O I
10.1590/S0100-40422007000700033
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The electrochemical applications of a CPE modified with chitosan for the determination of Cu(II) in wastewater samples using anodic stripping voltammetry are described. The best voltammetric response was observed for a paste containing 25% m/m of chitosan. A 0.10 mol L-1 NaNO3 solution (pH 6.5) as supporting electrolyte, a pre-concentration potential of -0.20 V, pre-concentration time of 270 s and a scan rate of 25 mV s(-1) were selected. The calibration graph was linear in the Cu(II) concentration range from 2.0 x 10(-7) to 7.4 x 10(-6) mol L-1, with a detection limit of 8.3 x 10(-8) mol L-1.
引用
收藏
页码:1673 / 1676
页数:4
相关论文
共 50 条
  • [1] Anodic stripping voltammetric determination of copper(II) using a functionalized carbon nanotubes paste electrode modified with crosslinked chitosan
    Janegitz, Bruno C.
    Marcolino-Junior, Luiz H.
    Campana-Filho, Sergio P.
    Faria, Ronaldo C.
    Fatibello-Filho, Orlando
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 142 (01) : 260 - 266
  • [2] Anodic stripping voltammetric determination of mercury in water using a chitosan-modified carbon paste electrode
    Marcolino, Luiz H. Junior
    Janegitz, Bruno C.
    Lourencao, Bruna C.
    Fatibello-Filho, Orlando
    [J]. ANALYTICAL LETTERS, 2007, 40 (16-18) : 3119 - 3128
  • [4] Carbon Paste Electrode Modified by Surfactant for Anodic Stripping Voltammetric Determination of Sulphadiazine
    Zhang Zheng-qi
    Chen Zhan-guang
    Chen Sheng-zong
    TAO Mei-juan and ZHANG Hong(Departnient of Chemistry and Chemical Engineering
    [J]. Chemical Research in Chinese Universities, 1994, (02) : 85 - 92
  • [5] Anodic stripping voltammetric determination of copper(II) with salicylaldoxime carbon paste electrodes
    Danet, AF
    Neagu, D
    Dondoi, MP
    Iliescu, N
    [J]. REVISTA DE CHIMIE, 2004, 55 (01): : 1 - 4
  • [6] Anodic stripping voltammetric determination of silver ion at a carbon paste electrode modified with carbon nanotubes
    Javad Tashkhourian
    Sana Javadi
    Fatemeh Nami Ana
    [J]. Microchimica Acta, 2011, 173 : 79 - 84
  • [7] Anodic stripping voltammetric determination of silver ion at a carbon paste electrode modified with carbon nanotubes
    Tashkhourian, Javad
    Javadi, Sana
    Ana, Fatemeh Nami
    [J]. MICROCHIMICA ACTA, 2011, 173 (1-2) : 79 - 84
  • [8] Anodic stripping voltammetric determination of titanium(IV) using a carbon paste electrode modified with cetyltrimethylammonium bromide
    Stadlober, M
    Kalcher, K
    Raber, G
    Neuhold, C
    [J]. TALANTA, 1996, 43 (11) : 1915 - 1924
  • [9] Catalytic adsorptive stripping voltammetric determination of copper(II) on a carbon paste electrode
    Ning Liu
    Jun-Feng Song
    [J]. Analytical and Bioanalytical Chemistry, 2005, 383 : 358 - 364
  • [10] Catalytic adsorptive stripping voltammetric determination of copper(II) on a carbon paste electrode
    Liu, N
    Song, JF
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) : 358 - 364