Apical Extrusion of Debris during Root Canal Preparation with ProTaper Next, WaveOne Gold and Twisted Files

被引:6
|
作者
Eliasz, Wojciech [1 ]
Czarnecka, Beata [2 ]
Surdacka, Anna [1 ]
机构
[1] Poznan Univ Med Sci, Dept Conservat Dent & Endodont, PL-61701 Poznan, Poland
[2] Poznan Univ Med Sci, Dept Biomat & Expt Dent, PL-61701 Poznan, Poland
关键词
endodontics; endodontic instruments; root canal preparation; RECIPROCATING SINGLE-FILE; EXTRUDED DEBRIS; ENDODONTIC RETREATMENT; POSTOPERATIVE PAIN; ROTARY SYSTEMS; INSTRUMENTS; UNIVERSAL; SURGERY; ABILITY;
D O I
10.3390/ma14216254
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
(1) Background: Apical extrusion of debris is an example of a complication that may arise during root canal treatment, and it has been proven to be an unavoidable occurrence during endodontic treatment by numerous authors. Even though it may not hinder the long-term outcome of treatment, it may lead directly to increased levels of postoperative pain and, therefore, lower levels of patient acceptance and satisfaction. The aim of the study was to assess the weight of apically extruded debris during root canal preparation with instruments that use different movement kinematics (rotary, reciprocating, and adaptive motion); (2) Methods: The study was performed using the Myers and Montgomery model. Sixty human premolar teeth were inserted into preweighed Eppendorf tubes and randomly classified into three groups. After manual glide-path preparation, teeth in each group were instrumented to working length set 1 mm short of the anatomical apex using the standard sequence provided by the manufacturers (for Group 1: ProTaper Next X1 & X2; for Group 2: WaveOne Gold Primary, for Group 3: Twisted Files SM1-SM3). Root canals were irrigated with 1 mL of 0.9% NaCl solution between each file insertion. The tubes with collected debris were stored in an incubator at 70 degrees C for 5 days in order to evaporate the liquid component. Measurement of the weight of extruded debris was performed by subtracting the preinstrumentation from the postinstrumentation weight of the tubes. The results were analyzed with Kruskal-Wallis ANOVA, with significance level set at 0.05; (3) Results: The weight of extruded debris was 0.337 mg (SD = 0.148) for Group 1, 0.305 mg (SD = 0.201) for Group 2, and 0.348 mg (SD = 0.135) for Group 3. (4) Conclusions: Engine-driven root canal preparation with the use of instruments ProTaper Next, WaveOne Gold and Twisted Files that use different movement kinematics (rotary, reciprocating, and adaptive motion) was associated with apical extrusion of debris to a similar extent.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Root Canal Transportation after Root Canal Preparation with ProTaper Next, WaveOne Gold, and Twisted Files
    Eliasz, Wojciech
    Kubiak, Kinga
    Poncyljusz, Wojciech
    Surdacka, Anna
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (11) : 1 - 8
  • [2] The Influence of Root Canal Preparation with ProTaper Next, WaveOne Gold, and Twisted Files on Dentine Crack Formation
    Eliasz, Wojciech
    Czarnecka, Beata
    Surdacka, Anna
    [J]. MACHINES, 2021, 9 (12)
  • [3] Apically extruded debris during root canal preparation using ProTaper Gold, ProTaper Universal, ProTaper Next, and RECIPROC instruments
    Cakici, Fatih
    Cakici, Elif B.
    Kucukekenci, Funda F.
    Uygun, Ahmet D.
    Arslan, Hakan
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2016, 39 (03): : 128 - 131
  • [4] Dentinal Crack Formation during Root Canal Preparations by the Twisted File Adaptive, ProTaper Next, ProTaper Universal, and WaveOne Instruments
    Karatas, Ertugrul
    Gunduz, Hicran Ates
    Kirici, Damla Ozsu
    Arslan, Hakan
    Topcu, Meltem Colak
    Yeter, Kubra Yesildal
    [J]. JOURNAL OF ENDODONTICS, 2015, 41 (02) : 261 - 264
  • [5] Quantitative Evaluation of Apically Extruded Debris of Root Canal Dentin Layer with WaveOne, ProTaper Next, ProTaper Gold Rotary File Systems
    Ali, Muhammad
    Ahmed, Muhammad Adeel
    Syed, Azeem Ul Yaqin
    Jamil, Asmat
    Khan, Seher Pervaiz
    AlMokhatieb, Ahmed A.
    Abdulwahed, Abdulaziz
    Al-Aali, Khulud A.
    Vohra, Fahim
    Abduljabbar, Tariq
    [J]. COATINGS, 2022, 12 (04)
  • [6] Comparative Analysis of Apical Root Crack Propagation after Root Canal Preparation at Different Instrumentation Lengths Using ProTaper Universal, ProTaper Next and ProTaper Gold Rotary Files: An In vitro Study
    Nishad, Sonalkumari Vakilram
    Shivamurthy, G. B.
    [J]. CONTEMPORARY CLINICAL DENTISTRY, 2018, 9 : S34 - S38
  • [7] Effect of glide path and apical preparation size on the incidence of apical crack during the canal preparation using Reciproc, WaveOne, and ProTaper Next systems in curved root canals: A stereomicroscope study
    Topcuoglu, Hueseyin Sinan
    Duzgun, Salih
    Akpek, Firdevs
    Topcuoglu, Gamze
    [J]. SCANNING, 2016, 38 (06) : 585 - 590
  • [8] Evaluation of apical extrusion of debris and centering ability in different nickel-titanium files during curved root canal preparation
    Yu, Dongsheng
    Guo, Li
    Gao, Jing
    Liu, Jie
    Yang, Deqin
    [J]. BMC ORAL HEALTH, 2023, 23 (01)
  • [9] Evaluation of apical extrusion of debris and centering ability in different nickel-titanium files during curved root canal preparation
    Dongsheng Yu
    Li Guo
    Jing Gao
    Jie Liu
    Deqin Yang
    [J]. BMC Oral Health, 23
  • [10] Apical extrusion of debris using ProTaper Universal and ProTaper Next rotary systems
    Kocak, M. M.
    Cicek, E.
    Kocak, S.
    Saglam, B. C.
    Yilmaz, N.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (03) : 283 - 286