Influence of the upstream slot geometry on the endwall cooling and phantom cooling of vane suction side surface

被引:32
|
作者
Du, Kun [1 ,2 ]
Li, Zhigang [1 ]
Li, Jun [1 ,3 ]
Sunden, Bengt [2 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
[2] Lund Univ, Div Heat Transfer, Dept Energy Sci, SE-22100 Lund, Sweden
[3] Collaborat Innovat Ctr Adv Aeroengine, Beijing 100191, Peoples R China
基金
瑞典研究理事会; 中国国家自然科学基金;
关键词
Vane endwall; Upstream slot geometry; Phantom cooling; Numerical simulations; TURBINE ROTOR PASSAGE; HEAT-TRANSFER; HOT STREAKS; PERFORMANCE; FLOW;
D O I
10.1016/j.applthermaleng.2017.04.143
中图分类号
O414.1 [热力学];
学科分类号
摘要
Modern gas turbines always operate at a high level of inlet temperature. The current inlet temperature in the aircraft and heavy duty gas turbines is higher than the melting point of the guide vane material. Consequently, advanced cooling schemes must be developed to ensure the safe operation of gas turbines. In the current study, numerical simulations were conducted to investigate the influence of the upstream slot geometry on the endwall cooling and phantom cooling of the vane suction side surface. Three-dimensional (3D) Reynolds-averaged Navier-Stokes (RANS) equations combined with the shear stress transport (SST) k - omega turbulence model were solved to conduct the simulations based on the validated turbulence model. The results indicate that the adiabatic cooling effectiveness in the upstream region of the stagnation is significantly increased by introducing the contoured upstream slot. However, the normal upstream slot obtains a relatively high adiabatic cooling effectiveness level in the downstream region of the stagnation. In the present research, the case with normalized amplitude (A) over bar = 0.75, initial phase angle phi = 45 degrees achieves the largest overall adiabatic cooling effectiveness near the vane leading edge. In contrast, the case with (A) over bar = 0.75, omega = 30 degrees attains the smallest overall adiabatic cooling effectiveness on the endwall surface. Moreover, the phantom cooling effectiveness on the vane suction side surface is relatively small relative to the adiabatic cooling effectiveness on the endwall. The case with the normal upstream slot achieves the largest phantom cooling effectiveness on the vane suction side surface compared with the contoured upstream slot. Overall, the contoured upstream slot significantly enhances the endwall cooling effectiveness by rearranging the distribution of the coolant mass flowrate at the slot outlet. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:688 / 700
页数:13
相关论文
共 50 条
  • [1] Effects of the swirling coolant jet from the upstream slot on the vane endwall cooling and the vane suction side phantom cooling
    Du, Kun
    Li, Zhigang
    Li, Jun
    Sunden, Bengt
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 121 : 952 - 966
  • [2] Effects of the mainstream turbulence intensity and slot injection angle on the endwall cooling and phantom cooling of the vane suction side surface
    Du, Kun
    Song, Liming
    Li, Jun
    Sunden, Bengt
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 112 : 427 - 440
  • [3] Effects of the layout of film holes near the vane leading edge on the endwall cooling and phantom cooling of the vane suction side surface
    Du, Kun
    Song, Liming
    Li, Jun
    Sunden, Bengt
    [J]. NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2017, 71 (09) : 910 - 927
  • [4] Effects of the cooling configurations layout near the first-stage vane leading edge on the endwall cooling and phantom cooling of the vane suction side surface
    Du, Kun
    Li, Jun
    Sunden, Bengt
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 123 : 1021 - 1034
  • [5] Turbine Vane Endwall Film Cooling and Pressure Side Phantom Cooling Performances With Upstream Coolant Flow at Various Injection Angles
    Bai, Bo
    Li, Zhigang
    Li, Jun
    Mao, Shuo
    Ng, Wing F.
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2022, 14 (11)
  • [6] Influence of the pressure side injection slot on the cooling performance of endwall surface
    Du, Kun
    Li, Zhigang
    Li, Jun
    Sunden, Bengt
    [J]. NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2018, 73 (08) : 517 - 534
  • [7] Effects of Upstream Step Geometries on Endwall Film Cooling and Phantom Cooling Performances of a Transonic Turbine Vane
    Bai, Bo
    Li, Zhigang
    Li, Jun
    Mao, Shuo
    Ng, Wing F.
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2022, 14 (12)
  • [8] Effects of Trenched Film Hole Configurations on the Endwall Film Cooling and Suction Side Phantom Cooling
    DU Kun
    LI Zhigang
    LI Jun
    [J]. Journal of Thermal Science, 2019, 28 (05) : 905 - 914
  • [9] Effects of Trenched Film Hole Configurations on the Endwall Film Cooling and Suction Side Phantom Cooling
    Kun Du
    Zhigang Li
    Jun Li
    [J]. Journal of Thermal Science, 2019, 28 : 905 - 914
  • [10] Effects of Trenched Film Hole Configurations on the Endwall Film Cooling and Suction Side Phantom Cooling
    Du Kun
    Li Zhigang
    Li Jun
    [J]. JOURNAL OF THERMAL SCIENCE, 2019, 28 (05) : 905 - 914