Flow injection chemiluminescence determination of catecholamines with electrogenerated hypochlorite

被引:76
|
作者
Zhang, CX
Huang, JC
Zhang, ZJ [1 ]
Aizawa, MS
机构
[1] Shaanxi Normal Univ, Dept Chem, Xian 710062, Peoples R China
[2] Tokyo Inst Technol, Dept Bioengn, Midori Ku, Yokohama, Kanagawa 226, Japan
[3] Luan Teachers Coll, Luan 237012, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
flow injection; chemiluminescence; catecholamine; luminol; electrolysis; pharmaceutical analysis;
D O I
10.1016/S0003-2670(98)00419-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection method for the determination of catecholamines based on the inhibition of the intensity of chemiluminescence from the luminol-hypochlorite system is described. The hypochlorite was electrogenerated on-line by constant current electrolysis, resulting in the elimination of the instability of hypochlorite solution prepared from commercially available sodium hypochlorite. The detection Limits are 6x10(-10) g ml(-1) for dopamine, 8x10(-10) g ml(-1) for adrenaline and 8x10(-10) g ml(-1) for isoprenaline. Linear ranges are 1x10(-9)-2x10(-8) g ml(-1) for dopamine, 2x10(-9) - 2x10(-8) g ml(-1) for adrenaline, 2x10(-9)-2x10(-8) g ml(-1) for isoprenaline. The relative standard deviations are lower than 2.8%. The proposed method has been applied to the determination of catecholamines in pharmaceutical injections with satisfactory results. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 50 条
  • [1] Flow injection chemiluminescence determination of etamsylate with electrogenerated hypochlorite
    Zhang, CX
    Huang, JC
    Feng, ML
    Zhang, ZJ
    [J]. ANALYTICAL LETTERS, 1998, 31 (11) : 1917 - 1928
  • [2] Flow injection chemiluminescence determination of isoniazid with electrogenerated hypochlorite
    Huang, JC
    Zhang, CX
    Zhang, ZJ
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (01): : 126 - 128
  • [3] Flow injection chemiluminescence determination of isoniazid with electrogenerated hypochlorite
    Jiachu Huang
    Chengxiao Zhang
    Zhujun Zhang
    [J]. Fresenius' Journal of Analytical Chemistry, 1999, 363 : 126 - 128
  • [4] Flow injection chemiluminescence determination of L-dopa with electrogenerated hypochlorite
    Huang, JC
    Zhang, CX
    Zhang, ZJ
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (01) : 41 - 43
  • [5] Determination of norfloxacin by flow injection electrogenerated chemiluminescence
    Ma, HY
    Zheng, XW
    Zhang, ZJ
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (07) : 857 - 860
  • [6] Determination of phloroglucinol by flow injection electrogenerated chemiluminescence
    Guo, ZH
    Zheng, XW
    Zhang, ZJ
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (04) : 461 - 463
  • [7] Flow-injection chemiluminescence determination of catecholamines
    Wolyniec, Elzbieta
    Niedzwiedzka, Urszula
    Kojlo, Anatol
    [J]. INSTRUMENTATION SCIENCE & TECHNOLOGY, 2007, 35 (02) : 219 - 231
  • [8] Flow-injection Chemiluminescence Determination of Catecholamines
    Cheng Xiao ZHANG
    Zhu Jun ZHANG(Department of Chemistry
    (Lu’an Teacher’s College
    [J]. Chinese Chemical Letters, 1998, (09) : 843 - 845
  • [9] Flow-injection chemiluminescence determination of catecholamines
    Huang, JC
    Zhang, CX
    Zhang, ZJ
    [J]. CHINESE CHEMICAL LETTERS, 1998, 9 (09) : 843 - 845
  • [10] Flow injection chemiluminescence determination of adreson with electrogenerated manganese QID
    Chen, XN
    Zhang, CX
    Lü, JR
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (09) : 1126 - 1128