Palatal bone thickness and associated factors in adult miniscrew placements: A cone-beam computed tomography study

被引:22
|
作者
Poon, Yi-Ching [1 ]
Chang, Hong-Po [1 ,2 ]
Tseng, Yu-Chuan [1 ,3 ]
Chou, Szu-Ting [3 ]
Cheng, Jung-Hsuan [3 ]
Liu, Pao-Hsin [4 ]
Pan, Chin-Yun [3 ]
机构
[1] Kaohsiung Med Univ, Coll Dent Med, Fac Dent, Kaohsiung, Taiwan
[2] Kaohsiung Municipal Hsiaokang Hosp, Dept Dent, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ Hosp, Dept Orthodont, Dent Clin, Kaohsiung 80756, Taiwan
[4] I Shou Univ, Dept Biomed Engn, Kaohsiung, Taiwan
来源
KAOHSIUNG JOURNAL OF MEDICAL SCIENCES | 2015年 / 31卷 / 05期
关键词
Bone thickness; Cone-beam computed; tomography; Frankfort-mandibular; plane angle; Miniscrews; Palatal bone; ANCHORAGE; SCREW;
D O I
10.1016/j.kjms.2015.02.002
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Palatal bone thickness measurements obtained by cone-beam computed tomography (CBCT) in 30 men and 28 women were evaluated for associated factors. Palatal bone thickness was measured at 20 locations unilateral to the midpalatal suture and posterior to the incisive foramen. Tongue position, presence of posterior crossbite, and palatal morphology were recorded. Lateral cephalograms acquired from CBCT data were used to calculate Frankfort-mandibular plane angles (FMA). At almost all sites, bone thickness was greater in males than in females, but the difference was statistically significant at only seven sites. Bone thickness showed no associations with tongue position, palatal morphology, or presence of posterior crossbite. In women, FMA significantly correlated with bone thickness at 12 locations. In conclusion, palatal bone thickness is unassociated with tongue position, posterior crossbite, or palatal morphology. In hyperdivergent women, however, available bone may be smaller than normal in the middle and posterior palatal areas; in such cases, a shorter than normal miniscrew may be needed to avoid penetrating the nasal cavity. Copyright (C) 2015, Kaohsiung Medical University. Published by Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
  • [1] Quantitative cone-beam computed tomography evaluation of palatal bone thickness for orthodontic miniscrew placement
    Gracco, Antonio
    Lombardo, Luca
    Cozzani, Mauro
    Siciliani, Giuseppe
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (03) : 361 - 369
  • [2] Assessment of the bone thickness of the palate on cone-beam computed tomography for placement of miniscrew-assisted rapid palatal expansion appliances
    Negrisoli, Silvia
    Angelieri, Fernanda
    Goncalves, Joao Roberto
    Pereira da Silva, Helio Doyle
    Maltagliati, Liliana Avila
    Raphaelli Nahas-Scocate, Ana Carla
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 161 (06) : 849 - 857
  • [3] Cone Beam Computed Tomography evaluation of palatal bone thickness for miniscrew placement in Down's syndrome
    Diniz-Freitas, M.
    Seoane-Romero, J.
    Fernandez-Varela, M.
    Abeleira, M. T.
    Diz, P.
    Cadarso-Suarez, C.
    Guler, I.
    Limeres, J.
    [J]. ARCHIVES OF ORAL BIOLOGY, 2015, 60 (09) : 1333 - 1339
  • [4] Evaluation of the palatal soft tissue thickness by cone-beam computed tomography
    Trang Vu
    Bayome, Mohamed
    Kook, Yoon-Ah
    Han, Seong Ho
    [J]. KOREAN JOURNAL OF ORTHODONTICS, 2012, 42 (06) : 291 - 296
  • [5] Predictive Factors Affecting the Maxillary Alveolar Bone Thickness: A Cone-Beam Computed Tomography Study
    Linjawi, Amal
    [J]. CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2020, 12 : 359 - 365
  • [6] Comparison of cephalometric measurements and cone-beam computed tomography-based measurements of palatal bone thickness
    Kim, Young-Jae
    Lim, Sung-Hoon
    Gang, Sung-Nam
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (02) : 165 - 172
  • [7] The evaluation of palatal bone thickness for implant insertion with cone beam computed tomography
    Sumer, A. P.
    Caliskan, A.
    Uzun, C.
    Karoz, T. B.
    Sumer, M.
    Cankaya, S.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (02) : 216 - 220
  • [8] Palatal bone thickness compared with cone-beam computed tomography in adolescents and adults for mini-implant placement
    Ryu, Jun-Ha
    Park, Jae Hyun
    Trang Vu Thi Thu
    Bayome, Mohamed
    Kim, YoonJi
    Kook, Yoon-Ah
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (02) : 207 - 212
  • [9] Palatal Bone Thickness in Different Growth Patterns of Dravidian Population Using Cone-Beam Computed Tomography Systems
    Tiwari, Akriti
    Dinesh, S. P. Saravana
    [J]. BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2021, 14 (03): : 1334 - 1337
  • [10] Palatal bone thickness at the implantation area of maxillary skeletal expander in adult patients with skeletal Class III malocclusion: a cone-beam computed tomography study
    Weiting Chen
    Kaili Zhang
    Dongxu Liu
    [J]. BMC Oral Health, 21