An implantable wireless bidirectional communication microstimulator for neuromuscular stimulation

被引:71
|
作者
Lee, SY [1 ]
Lee, SC [1 ]
机构
[1] Natl Chung Cheng Univ, Dept Elect Engn, Commun & Biol Integrated Circuit Lab, Chiayi 621, Taiwan
关键词
bidirectional; CMOS; microstimulator; neuromuscular stimulation; radio frequency (RF); wireless;
D O I
10.1109/TCSI.2005.857770
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the integrated circuit design for a wireless bidirectional transmission microstimulator. This implantable device is composed of an internal radio-frequency (RF) front-end circuit, a control circuit, a stimulator, and an on-chip transmitter. A 2-MHz amplitude-shift keying modulated signal, including the power and data necessary for the implantable device, is received, and a stable 3-V dc voltage and digital data will be extracted to further execute neuromuscular stimulation. The current-mode microstimulator can produce a bidirectional output current with 8-bit resolution for stimulation. The maximum stimulation current is 1 mA while the stimulation frequency is from 20 Hz to 2 kHz and the pulsewidth of stimulation current is from 150 to 500 mu s. Furthermore, the system can acquire the biological sensing signal by means of an on-chip transmitter. Most of the signal processing circuits have been designed with low-power schemes to reduce the power consumption, and the performance is also conformed to the requirements of the microstimlator. All of the circuits except for the RF link are combined in a single chip and implemented in TSMC 0.35-mu m 2P4M standard CMOS process.
引用
收藏
页码:2526 / 2538
页数:13
相关论文
共 50 条
  • [1] A single-channel implantable microstimulator for functional neuromuscular stimulation
    Ziaie, B
    Nardin, MD
    Coghlan, AR
    Najafi, K
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (10) : 909 - 920
  • [2] A new implantable microstimulator dedicated to selective stimulation of the bladder
    Robin, S
    Sawan, M
    Harvey, JF
    Abdel-Gawad, M
    Abdel-Baky, TM
    Elhilali, MM
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 1792 - 1795
  • [3] A Programmable Implantable Microstimulator SoC With Wireless Telemetry: Application in Closed-Loop Endocardial Stimulation for Cardiac Pacemaker
    Lee, Shuenn-Yuh
    Su, Mario YuCheng
    Liang, Ming-Chun
    Chen, You-Yin
    Hsieh, Cheng-Han
    Yang, Chung-Min
    Lai, Hsin-Yi
    Lin, Jou-Wei
    Fang, Qiang
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2011, 5 (06) : 511 - 522
  • [4] Wireless Front-End With Power Management for an Implantable Cardiac Microstimulator
    Lee, Shuenn-Yuh
    Hsieh, Cheng-Han
    Yang, Chung-Min
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2012, 6 (01) : 28 - 38
  • [5] A multiparameter implantable microstimulator SOC
    Wang, CC
    Lee, TJ
    Hsiao, YT
    Chio, UF
    Huang, CC
    Chin, JJJ
    Hsueh, YH
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2005, 13 (12) : 1399 - 1402
  • [6] A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication
    Piech, David K.
    Johnson, Benjamin C.
    Shen, Konlin
    Ghanbari, M. Meraj
    Li, Ka Yiu
    Neely, Ryan M.
    Kay, Joshua E.
    Carmena, Jose M.
    Maharbiz, Michel M.
    Muller, Rikky
    NATURE BIOMEDICAL ENGINEERING, 2020, 4 (02) : 207 - 222
  • [7] A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication
    David K. Piech
    Benjamin C. Johnson
    Konlin Shen
    M. Meraj Ghanbari
    Ka Yiu Li
    Ryan M. Neely
    Joshua E. Kay
    Jose M. Carmena
    Michel M. Maharbiz
    Rikky Muller
    Nature Biomedical Engineering, 2020, 4 : 207 - 222
  • [8] VLSI implementation of implantable wireless power and data transmission micro-stimulator for neuromuscular stimulation
    Lee, SY
    Lev, SC
    Chen, JJJ
    IEICE TRANSACTIONS ON ELECTRONICS, 2004, E87C (06) : 1062 - 1068
  • [9] A One-time Implantable Wireless Power Bidirectional Transmission Spinal Cord Stimulation System
    Wang, Chua-Chin
    Hsu, Chia-Hao
    Tseng, Shao-Bin
    Shmilovitz, Doron
    2010 INTERNATIONAL SYMPOSIUM ON VLSI DESIGN AUTOMATION AND TEST (VLSI-DAT), 2010, : 288 - 291
  • [10] IMPLANTABLE FUNCTIONAL NEUROMUSCULAR STIMULATION IN THE TETRAPLEGIC HAND
    KEITH, MW
    PECKHAM, PH
    THROPE, GB
    STROH, KC
    SMITH, B
    BUCKETT, JR
    KILGORE, KL
    JATICH, JW
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14A (03): : 524 - 530