摘要
The SuperNEMO experiment is devoted to neutrinoless double beta decay detection and main R&D of the detector design is already finished. The crucial role in such low background experiments plays the suppression of background. One of the most important sources of radioactivity is the radon gas and its daughter products. The radon activity in the volume of the detector will be reduced significantly using the antiradon facility already installed in the Modane underground laboratory which provides air with a radon volume activity at the order of similar to mBq/m(3). To be able to measure low radon activities at the output of this antiradon facility in reasonable time of measurement the develoment of new ultra-sensitive radon detector is currently carried out. The detection is based on electrostatic collection of radon progenies (Po-214, Po-218) on a Si PIN diode. Our idea is to increase the volume of the detector up to 1 m(3) divided into smaller subdetectors (50-100 l) to improve the detection effectiveness and consequently the sensitivity. Two prototypes of sensitive radon detectors were constructed (50 l and 300 l). Preliminary results of the detection efficiency and the background measurement for the first prototype are also presented.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Radon Mitigation Strategy and Results for the SuperNEMO Experiment
    Liu, Xin Ran
    XXVII INTERNATIONAL CONFERENCE ON NEUTRINO PHYSICS AND ASTROPHYSICS (NEUTRINO2016), 2017, 888
  • [2] ULTRA-SENSITIVE IONIZATION DETECTOR FOR PERMANENT GAS ANALYSIS
    BERRY, R
    NATURE, 1960, 188 (4750) : 578 - 579
  • [3] Radiopurity requirements for the SuperNEMO experiment and the BiPo detector
    Eurin, Guillaume
    TOPICAL RESEARCH MEETING: PROSPECTS IN NEUTRINO PHYSICS (NUPHYS2013), 2015, 598
  • [4] BiPo: A dedicated radiopurity detector for the SuperNEMO experiment
    Gomez, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 52 - 55
  • [5] New ultra-sensitive Michelson-Morely experiment
    Tobar, ME
    Hartnett, JG
    Anstie, JD
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 94 - 95
  • [6] Ultra-sensitive mid-wavelength-infrared upconversion detector
    Li, Yan
    He, Yuhang
    Wang, Yinqi
    He, Weiji
    Gu, Guohua
    Chen, Qian
    OPTICS AND LASER TECHNOLOGY, 2024, 168
  • [7] Ultra-sensitive mid-wavelength-infrared upconversion detector
    Li, Yan
    He, Yuhang
    Wang, Yinqi
    He, Weiji
    Gu, Guohua
    Chen, Qian
    Optics and Laser Technology, 2024, 168
  • [8] Measurement of radon diffusion through shielding foils for the SuperNEMO experiment
    Mamedov, F.
    Cermak, P.
    Smolek, K.
    Stekl, I.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [9] DEVELOPMENT OF AN ULTRA-SENSITIVE HOMOGENEOUS IMMUNOASSAY FOR FERRITIN
    Kano, M.
    Tachibana, R.
    Ito, Y.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S841 - S841
  • [10] Development of an ultra-sensitive HBsAg microparticle assay
    Pelzer, C
    Ali, A
    Coleman, PF
    TRANSFUSION, 2003, 43 (09) : 125A - 126A