Real-time 3-dimensional echocardiography imaging for right ventricular endomyocardial biopsy: A comparison with fluoroscopy

被引:25
|
作者
McCreery, CJ [1 ]
McCulloch, M [1 ]
Ahmad, M [1 ]
deFilippi, CR [1 ]
机构
[1] Univ Maryland, Div Cardiol, Med Branch, Dept Internal Med, Baltimore, MD 21201 USA
关键词
D O I
10.1067/mje.2001.113651
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Real-time 3-dimensional (RT3D) echocardiography has the potential to precisely identify the position of an object in 3-dimensional space. Therefore, we hypothesized that RT3D echocardiography could rapidly facilitate accurate placement of a bioptome within the right ventricle and may offer advantages over a fluoroscopically guided approach. During 63 routine right ventricular biopsy procedures (total of 315 biopsy attempts) in 33 cardiac allograft recipients, the bioptome was initially guided against the intraventricular septum with the use of biplane fluoroscopy. Bioptome position was then evaluated by RT3D echocardiography by using the Volumetrics Model 1 with the transducer placed at the apex. Multiple long-axis and short-axis planes were simultaneously visualized and customized to identify the tip of the bioptome. Bioptome placement was prospectively classified as septal, free wall/septal junction, or free wall Of the 36 patients studied, 33 (91%) had adequate RT3D images. Of 315 bioptome placements visualized by RT3D echocardiography after fluoroscopic placement, bioptome position against the septum was confirmed in 113 (36%), against the septal/free wall (anterior or posterior) junction in 140 (44%), against the free wall in 60 (19%), and in the coronary sinus in 2 (1%). RT3D echocardiography is readily feasible for use in the majority of transplant patients undergoing right ventricular endomyocardial biopsy. Visualization of the bioptome in multiple simultaneous planes allows accurate localization of the biopsy site. The potential for improved localization of the bioptome tip in the right ventricle may have important clinical implications for augmenting the efficacy of this procedure.
引用
收藏
页码:927 / 933
页数:7
相关论文
共 50 条
  • [1] The efficacy of real-time 3-dimensional echocardiography for right ventricular biopsy
    Aggarwal, M
    Drachenberg, C
    Douglass, L
    DeFilippi, C
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (11) : 1208 - 1212
  • [2] The efficacy of real time 3-dimensional echocardiography for right ventricular biopsy
    Aggarwal, M
    Drachenberg, C
    Douglass, L
    deFilippi, C
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 265A - 265A
  • [3] Real-time three-dimensional echocardiography is superior to two-dimensional echocardiography and fluoroscopy in guidance of endomyocardial biopsy
    Amitai, ME
    Schnittger, I
    Chow, J
    Brown, P
    Liang, DH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 355A - 355A
  • [4] Initial experience with volume-rendered, real-time three dimensional echocardiography in right ventricular endomyocardial biopsy
    Firek, B
    Higginbotham, M
    Russel, S
    Adams, D
    Landolfo, C
    Kisslo, J
    EUROPEAN HEART JOURNAL, 2000, 21 : 580 - 580
  • [5] Normal values of right ventricular size and function by real-time 3-dimensional echocardiography: Comparison with cardiac magnetic resonance imaging
    Gopal, Aasha S.
    Chukwu, Ebere O.
    Iwuchukwu, Chizor J.
    Katz, Alan S.
    Toole, Rena S.
    Schapiro, William
    Reichek, Nathaniel
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (05) : 445 - 455
  • [6] Assessment of left ventricular dyssynchrony with real-time 3-dimensional echocardiography: Comparison with Doppler tissue Imaging
    Takeuchi, Masaaki
    Jacobs, Avrurn
    Sugeng, Lissa
    Nishikage, Tomoko
    Nakai, Hirorni
    Weincrt, Lynn
    Salgo, Ivan S.
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (12) : 1321 - 1329
  • [7] Real-Time 3-Dimensional Echocardiography
    Pan Cuizhen
    Shu Xianhong
    Wang Chunsheng
    Chen Hao
    CIRCULATION, 2010, 122 (02) : E345 - E345
  • [8] Reconstructed versus real-time 3-dimensional echocardiography: Comparison with magnetic resonance imaging
    Jenkins, Carly
    Leano, Rodel
    Chan, Jonathan
    Marwick, Thomas H.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (07) : 862 - 868
  • [9] Real-Time 3-Dimensional Echocardiography Is an Indispensable Tool for Assessing Right Ventricular Function in Patients with Right Ventricular Pressure Overload
    Toyono, Manalorno
    Matsumura, Yoshlki
    Yamano, Tetsuhiro
    Takasaki, Kunltsugu
    Saraiva, Roberto M.
    Greenberg, Neil L.
    Agler, Deborah A.
    Shiota, Takahim
    CIRCULATION, 2008, 118 (18) : S607 - S607
  • [10] Free-Floating Right Ventricular Thrombus as Assessed by Real-time 3-Dimensional Transesophageal Echocardiography
    Tsujimoto, Satoshi
    Miyasaka, Yoko
    Yokoe, Hiroshi
    Maeba, Hirofumi
    Yuasa, Fumio
    Dote, Kinuko
    Iwasaka, Toshiji
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (01) : 127 - 128