Performance of a heat pump using direct expansion solar collectors

被引:101
|
作者
Ito, S [1 ]
Miura, N [1 ]
Wang, K [1 ]
机构
[1] Kanagawa Inst Technol, Dept Mech Syst Engn, Atsugi, Kanagawa 2430292, Japan
关键词
D O I
10.1016/S0038-092X(98)00124-8
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Theoretical and experimental studies were made on the thermal performance of a hear pump that used a bare flat-plate collector as the evaporator. The analysis used empirical equations to express the electric power consumption of the compressor and coefficient of performance (COP), as functions of temperature of evaporation at the evaporator and that of the heat transfer medium (water) at the inlet of the condenser. The experimental heat pump had a compressor with a rated capacity of 350 W and collectors with the total area of 3.24 m(2) Around noon in winter the evaporator temperature was found to be about 17 degrees C higher than the ambient air temperature of 8 degrees C, and a COP of about 5.3 was obtained when the water temperature at the condenser inlet was 40 degrees C. These measured evaporation temperatures and COPs were in good agreement with those predicted by the analysis. According to the analysis, the total area of the collectors in the experiment was appropriate for the heat pump system. Also, the l-mm thickness of the collector's copper plate used in the experiment could be 0.5 mm with little reduction of COP. The pitch of the tube soldered to the copper plate for the refrigerant flow was 100 mm in the experiment, but the COP would only be reduced by about 4% if the pitch were changed to 190 mm. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 50 条
  • [1] Performance of a heat pump using direct expansion solar collectors
    Ito, S.
    Miura, N.
    Wang, K.
    Solar Energy, 65 (03): : 189 - 196
  • [2] COMPARATIVE EXPERIMENTAL RESEARCH ON PERFORMANCE OF TWO DIRECT EXPANSION SOLAR HEAT PUMP COLLECTORS/EVAPORATORS
    Zheng S.
    Yao J.
    Zhao Y.
    Chen D.
    Dai Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (04): : 487 - 491
  • [3] Studies of heat pumps using direct expansion type solar collectors
    Ito, S
    Miura, N
    Takano, Y
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 60 - 64
  • [4] Performance prediction of a direct expansion solar assisted heat pump using artificial neural networks
    Mohanraj, M.
    Jayaraj, S.
    Muraleedharan, C.
    APPLIED ENERGY, 2009, 86 (09) : 1442 - 1449
  • [5] Performance of hydrocarbon mixture in a direct expansion solar assisted heat pump system
    Paradeshi, L.
    Srinivas, M.
    Jayaraj, S.
    HEAT AND MASS TRANSFER, 2019, 55 (04) : 965 - 977
  • [6] THERMAL PERFORMANCE OF A DIRECT EXPANSION SOLAR-ASSISTED HEAT-PUMP
    CHATURVEDI, SK
    SHEN, JY
    SOLAR ENERGY, 1984, 33 (02) : 155 - 162
  • [7] Performance of hydrocarbon mixture in a direct expansion solar assisted heat pump system
    L. Paradeshi
    M. Srinivas
    S. Jayaraj
    Heat and Mass Transfer, 2019, 55 : 965 - 977
  • [8] Analysis of a direct expansion solar assisted heat pump using different refrigerants
    Chata, FBG
    Chaturvedi, SK
    Almogbel, A
    ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (15-16) : 2614 - 2624
  • [9] Thermodynamic analysis on performance of direct expansion solar assisted heat pump water heater
    Engineering Research Center of Solar Power and Refrigeration, Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240, China
    Huagong Xuebao, 2006, SUPPL. (110-115):
  • [10] Influence of subcooling on performance of direct-expansion solar-assisted heat pump
    Wang, Baigong
    Kong, Xiangqiang
    Yan, Xunzheng
    Shang, Yanping
    Li, Ying
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 122 : 201 - 209