Recent Progress in Round-Robin Test of Repetitive Partial Discharge Inception Voltage Measurements on Complete Winding of 4 kW Random-Wound Motor

被引:0
|
作者
Kikuchi, Yusuke [1 ]
Ishida, Takahiro [2 ]
Ueno, Takahisa [3 ]
Kanazawa, Seiji [4 ]
Nagao, Masayuki [5 ]
Hikita, Masayuki [6 ]
Murakami, Yoshinobu [5 ]
Nagata, Masayoshi [1 ]
机构
[1] Univ Hyogo, 2167 Shosha, Himeji, Hyogo 6712280, Japan
[2] Shizuoka Inst Sci & Tech, 2200-2 Toyosawa, Shizuoka 4378555, Japan
[3] Oita Natl Coll Tech, 1666 Maki, Oita 8700152, Japan
[4] Oita Univ, 700 Dannoharu, Oita 870119, Japan
[5] Toyohashi Univ Tech, Hibarigaoka 1-1,Tempaku Cho, Toyohashi, Aichi 4418580, Japan
[6] Kyushu Inst Tech, Tobata Ku, Sensuicho 101, Kitakyushu, Fukuoka 8048550, Japan
关键词
Inverter surge; Partial discharge; Round-robin test; IEC; Humidity effects; MAGNET WIRES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the results of round-robin test (RRT) of repetitive partial discharge inception voltage (RPDIV) measurements with a stator coil winding of 4 kW random wound motor. Nine independent laboratories in Japan participated in the RRT in order to validate evaluation procedures described in IEC 60034-18-41. The results provided new insights into RPDIV measurements with complete windings such as ambient humidity and pre-discharge effects.
引用
收藏
页码:159 / 162
页数:4
相关论文
共 3 条
  • [1] Round-Robin Test of Repetitive Partial Discharge Inception Voltage Measurements on Complete Winding of 4 kW Random-Wound Motor
    Kikuchi, Yusuke
    Nagata, Masayoshi
    Kanazawa, Seiji
    Ishida, Takahiro
    Nagao, Masayuki
    Murakami, Yoshinobu
    Ueno, Takahisa
    Hikita, Masayuki
    [J]. 2016 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2016, : 248 - 251
  • [2] A Round-Robin Test Study of Partial Discharge Inception Voltage in Aeronautic Cables
    Hahner, T.
    Rybsky, P.
    Cotton, I
    Lowndes, R.
    Albert, L.
    Thomas, C.
    Dinculescu, S.
    Teyssedre, G.
    [J]. PROCEEDINGS OF 2020 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2020), 2020, : 185 - 189
  • [3] Electrical Aging Test and Repetitive Partial Discharge Inception Voltage on Random Wire Wound Winding Insulation
    Guastavino, F.
    Porcile, F.
    Ratto, A.
    Cordano, D.
    Secondo, G.
    [J]. 2014 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2014, : 510 - 513