Electrical Performance Analysis of a 27 kW Grid-Connected PV System with Soiling and Shading in Morelos Mexico

被引:0
|
作者
Sanchez-Perez, P. A. [1 ]
Martinez Escobar, D. [1 ]
Angel Ruiz, E. O. [1 ]
Santos Magdaleno, R. [1 ]
Ortega Cruz, Jose [1 ]
Sanchez Juarez, A. [1 ]
机构
[1] Inst Energias Renovables, Privada Xochicalco S-N, Temixco 62580, Morelos, Mexico
关键词
photovoltaic system; performance ratio; electrical performance; grid-connected; soiling;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The favorable solar resource in Mexico and the current issues with the oil industry have encouraged the use of renewable energies such as solar photovoltaic systems connected to the grid. This paper presents the performance results of a polycrystalline silicon PV system connected to the grid in Morelos, Mexico. It provides information about the actual energy yield of newer PV plants under local climate conditions, temperature stress, shading and soiling. The PV system generated 35.15 MWh during one year of operation while a simulation of the same system generated 45.81 MWh. The average performance ratio (PR) obtained was 0.75 that is was higher that the simulated value of 0.71 due to overestimation of the solar resource.
引用
收藏
页码:1990 / 1994
页数:5
相关论文
共 50 条
  • [1] Comparative study of system performance of two 2.4 kW grid-connected PV installations in Tepic-Nayarit and Temixco-Morelos in Mexico
    Messina, Sarah
    Paz Hernandez Rosales, I.
    Saldana Duran, Claudia E.
    Jesus Quinones, J.
    Nair, P. K.
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 161 - +
  • [2] Performance Analysis of Grid-Connected PV System
    Elbaset, Adel A.
    Hassan, M. S.
    Ali, Hamdi
    PROCEEDINGS OF 2016 EIGHTEENTH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2016, : 675 - 682
  • [3] Performance results and analysis of 3 kW grid-connected PV systems
    So, Jung Hun
    Jung, Young Seok
    Yu, Gwon Jong
    Choi, JuYeop
    Choi, Jae Ho
    RENEWABLE ENERGY, 2007, 32 (11) : 1858 - 1872
  • [4] Performance and economic analysis of a 27kW grid-connected photovoltaic system in Suriname
    Raghoebarsing, Amrita
    Kalpoe, Anand
    IET RENEWABLE POWER GENERATION, 2017, 11 (12) : 1545 - 1554
  • [5] Performance Analysis of 58 kW Grid-Connected Roof-top Solar PV System
    Singh, Suresh
    Kumar, Rakesh
    Vijay, Vivek
    2014 6TH IEEE POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2014,
  • [6] Performance Analysis of Grid-Connected 10.6 kW (Commercial) Solar PV Power Generation System
    Santosh Kumar Sharma
    Palwalia D.K.
    Shrivastava V.
    Applied Solar Energy (English translation of Geliotekhnika), 2019, 55 (05): : 269 - 281
  • [7] The Effect of Shading with Different PV Array Configurations on the Grid-Connected PV System
    Mehiri, Abdelbasset
    Hamid, Abdul-Kadir
    Almazrouei, Sumayya
    PROCEEDINGS OF 2017 INTERNATIONAL RENEWABLE & SUSTAINABLE ENERGY CONFERENCE (IRSEC' 17), 2017, : 669 - 674
  • [8] Preliminary analysis of the performance for 5 kW grid-connected photovoltaic system
    Zainuddin, HB
    bin Yatim, B
    bin Sopian, K
    ADVANCES IN MALAYSIAN ENERGY RESEARCH 2000, 2001, : 25 - 30
  • [9] Performance of PV Grid-Connected System Under Grid Failure
    Brahim, Mouhanned
    Belhadj, Jamel
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2013, 3 (04): : 754 - 762
  • [10] A study on the performance analysis of the Grid-connected PV-AF system
    Seo, Hyo-Ryong
    Kim, Gyeong-Hun
    Ali, Mohd Hasan
    Park, Minwon
    Yu, In-keun
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-4, 2007, : 1601 - 1605