Energy audit in Athens metro stations for identifying energy consumption profiles of stationary loads

被引:5
|
作者
Zarkadoula, Maria [1 ]
Giannakopoulou, Kanellina [1 ]
Goumas, George [2 ]
Tsarmpopoulou, Maria [1 ]
Leoutsakos, George [3 ]
Deloukas, Alexandros [4 ]
Apostolopoulos, Ioannis [5 ]
Kiriazidis, Dimitris [6 ]
机构
[1] Ctr Renewable Energy Sources & Saving, Dept Environm & Transport, Div Energy Efficiency, Athens, Greece
[2] Ctr Renewable Energy Sources & Saving, Dept Energy Investments Support, Div Energy Efficiency, Athens, Greece
[3] Attiko Metro, Directorate Syst Engn, Athens, Greece
[4] Attiko Metro, Directorate Res & Technol, Athens, Greece
[5] Urban Rail Transport, Directorate Syst Maintenance, Sub Directorate Electrificat Maintenance, Athens, Greece
[6] Urban Rail Transport, Directorate Syst Maintenance, Athens, Greece
关键词
Metro station; energy audit; energy consumption; energy profiles over time; energy recovery; SUBWAY STATIONS; BRAKING ENERGY; SYSTEM; MODEL;
D O I
10.1080/14786451.2022.2028787
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Metro transportation systems are significant energy consumers. Apart from the traction system, considerable amounts of electricity are consumed in metro stations. In the present study, energy audits of two Athens metro stations were conducted to ensure a detailed overview of energy consumption per stationary load. Data from on-site surveys as well as real-time measurements were elaborated. The energy profile over time was developed for the measured electrical loads. Results have shown that the total energy consumption of Sepolia and Peristeri stations was 117.09 and 99.17 kWh/m(2)/year respectively, as well as 0.12 and 0.52 kWh/passenger/year. Lighting and small power were significant consumers (23.3% of total energy consumed in Sepolia station, 51.5% in Peristeri station). The natural, piston effect induced ventilation system in Peristeri station showed significantly lower energy consumption (7.4%) than that of Sepolia station (25.9%) using forced ventilation for stations and tunnels.
引用
下载
收藏
页码:1142 / 1163
页数:22
相关论文
共 50 条
  • [1] Stationary or onboard energy storage systems for energy consumption reduction in a metro network
    Barrero, R.
    Tackoen, X.
    van Mierlo, J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART F-JOURNAL OF RAIL AND RAPID TRANSIT, 2010, 224 (F3) : 207 - 225
  • [2] Energy saving in metro systems: Simultaneous optimization of stationary energy storage systems and speed profiles
    Ahmadi, Saeed
    Dastfan, Ali
    Assili, Mohsen
    JOURNAL OF RAIL TRANSPORT PLANNING & MANAGEMENT, 2018, 8 (01) : 78 - 90
  • [3] An Algorithm to Optimize Speed Profiles of the Metro Vehicles for Minimizing Energy Consumption
    Calderaro, Vito
    Galdi, Vincenzo
    Graber, Giuseppe
    Piccolo, Antonio
    Cogliano, Dario
    2014 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2014, : 813 - 819
  • [4] Benchmarking Energy Management Systems in Metro Stations
    Rajabi, Samira
    Behairy, Salwa
    ICSDEC 2016 - INTEGRATING DATA SCIENCE, CONSTRUCTION AND SUSTAINABILITY, 2016, 145 : 1088 - 1095
  • [5] ENERGY AUDIT AS TOOL FOR DECREASING OF ENERGY CONSUMPTION
    Tirshu, M.
    Zaitsev, D.
    Golub, I
    PROBLEMELE ENERGETICII REGIONALE, 2013, (03): : 73 - 79
  • [6] An energy-efficient metro speed profiles for energy savings: application to the Valencia metro
    Villalba Sanchis, Ignacio
    Salvador Zuriaga, Pablo
    EFFICIENT, SAFE AND INTELLIGENT TRANSPORT, 2016, 18 : 226 - 233
  • [7] An energy-efficient metro speed profiles for energy savings: application to the Valencia metro
    Villalba Sanchis, Ignacio
    Salvador Zuriaga, Pablo
    XII CONGRESO DE INGENIERIA DEL TRANSPORTE, 2016, : 1820 - 1832
  • [8] Optimal design of metro automatic train operation speed profiles for reducing energy consumption
    Dominguez, M.
    Fernandez, A.
    Cucala, A. P.
    Lukaszewicz, P.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART F-JOURNAL OF RAIL AND RAPID TRANSIT, 2011, 225 (F5) : 463 - 473
  • [9] Intelligent Energy Efficiency Measures for Underground Metro Stations
    Pande, Om Hari
    Jain, Rajesh Kr
    Chauhan, Mayank Prakash
    ASHRAE TRANSACTIONS 2020, VOL 126, 2020, 126 : 267 - 274
  • [10] Reducing energy consumption by energy management and energy audits in the pumping stations
    Kaddari, Mohamed
    El Mouden, Mahmoud
    Hajjaji, Abdelowahed
    Semlali, Abdellah
    2018 RENEWABLE ENERGIES, POWER SYSTEMS & GREEN INCLUSIVE ECONOMY (REPS-GIE), 2018,