Development of an acetylene optical frequency standard at 1.5 μm and its applications

被引:5
|
作者
Nakagawa, K [1 ]
Onae, A [1 ]
机构
[1] Univ Electrocommun, Inst Laser Sci, Chofu, Tokyo 1818585, Japan
关键词
optical frequency standard; acetylene; optical frequency measurement; optical communications;
D O I
10.1117/12.424485
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report the recent progress of our work on the development of an optical frequency standard in the 1.5 mum region based on a Doppler-free acetylene absorption. We have developed compact and portable acetylene-stabilized diode lasers for practical use. We have realized the frequency stability and reproducibility of about 2 x 10(-13) and 2 x 10(-11) respectively using a third-harmonic signal detection. We have measured the absolute frequency of the acetylene transition with an uncertainty of about 10(-10) using a frequency chain based on a two-color mode-locked fiber laser. One of the important applications of the acetylene optical frequency standard is the WDM optical communication system, which requires precise absolute frequency references for a hundred of channel frequencies in the wavelength region of 1530 - 1565 nm. We have developed a wide-range heterodyne optical phase-locked diode laser using the acetylene-stabilized laser as a master in order to realize the WDM channel frequency standards.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 50 条
  • [1] Development of a compact acetylene optical frequency standard at 1.5μm
    Nakagawa, K
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 204 - 205
  • [2] Optical frequency measurement of the acetylene transitions at 1.5 μm
    Nakagawa, K
    Yamaguchi, A
    Kourogi, M
    Imai, K
    Onae, A
    Okumura, K
    Yoda, J
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 402 - 403
  • [3] Development of a 1.5 micron acetylene stabilised frequency standard and the measurement of its frequency using single Sr+ standard
    Czajkowski, A
    Madej, AA
    Siemsen, KJ
    Bernard, JE
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 566 - 567
  • [4] Development of a Fibre-Based Acetylene Optical Frequency Standard at 1.54 μm
    Manamanni, Karim
    Roncin, Vincent
    Sahni, Mohamed
    Du-Burck, Frederic
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2019,
  • [5] A frequency measurement system for an optical frequency standard at 1.5 μm
    Onae, A
    Okumura, K
    Yoda, J
    Nakagawa, K
    Kourogi, M
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 212 - 213
  • [6] Towards an accurate frequency standard at 1.5 μ m based on the acetylene overtone band transition
    Onae, A
    Okumura, K
    Yoda, J
    Nakagawa, K
    Yamaguchi, A
    Kourogi, M
    Imai, K
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 400 - 401
  • [7] Toward an accurate frequency standard at 1.5 μm based on the acetylene overtone band transition
    Onae, A
    Okumura, K
    Yoda, J
    Nakagawa, K
    Yamaguchi, A
    Kourogi, M
    Imai, K
    Widiyatomoko, B
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 563 - 566
  • [8] Accurate optical frequency atlas of the 1.5-mu m bands of acetylene
    Nakagawa, K
    deLabachelerie, M
    Awaji, Y
    Kourogi, M
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1996, 13 (12) : 2708 - 2714
  • [9] 1.5 μm - optical frequency standard iodine stabilized in the 10-15 range for space applications
    Philippe, C.
    Gillot, J.
    Holleville, D.
    Lours, M.
    Le Targat, R.
    Wolf, P.
    Acef, O.
    Leveque, T.
    Le Goff, R.
    2017 JOINT CONFERENCE OF THE EUROPEAN FREQUENCY AND TIME FORUM AND IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (EFTF/IFC), 2017, : 471 - 474
  • [10] Absolute frequency measurement of a 1.5-μm acetylene standard by use of a combined frequency chain and femtosecond comb
    Edwards, CS
    Margolis, HS
    Barwood, GP
    Lea, SN
    Gill, P
    Huang, GL
    Rowley, WRC
    OPTICS LETTERS, 2004, 29 (06) : 566 - 568