Endoscopic Closure of an Acute Duodenal Perforation Occurring during Endoscopic Ultrasound Using Endoclips and Polyglycolic Acid Sheets with Fibrin Glue

被引:0
|
作者
Matsuoka, Mana [1 ]
Kobayashi, Katsumasa [1 ]
Okura, Yukito [1 ]
Mochida, Tomohiro [1 ]
Nozaka, Takahito [1 ]
Sato, Ayako [1 ]
Yauchi, Masato [1 ]
Matsumoto, Taichi [1 ]
Furumoto, Yohei [1 ]
Horiuchi, Takao [1 ]
Asano, Toru [1 ]
机构
[1] Tokyo Metropolitan Bokutoh Hosp, Dept Gastroenterol, Tokyo, Japan
关键词
Duodenal perforation; Endoscopic closure; Polyglycolic acid sheets; Fibrin glue; Case report; MANAGEMENT;
D O I
10.1159/000512474
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Acute duodenal perforation during endoscopic ultrasound (EUS) is a serious complication. The conventional endoscopic treatment for duodenal perforations such as endoscopic clipping is unsatisfactory; recently, the effectiveness of over-the-scope clipping (OTSC) has been reported. A 91-year-old woman was referred to our hospital with the chief complaint of jaundice. Contrast-enhanced computed tomography showed a 2-cm mass in the pancreatic head; we planned EUS-guided fine-needle aspiration. During exploration for a puncture route from the duodenal bulb using a linear echoendoscope under carbon dioxide insufflation, the duodenal lumen was suddenly filled with blood. A perforation <15 mm was identified in the superior duodenal horn. We attempted an endoscopic closure with multiple endoclips but could not completely close the perforation site. Strips of bioabsorbable polyglycolic acid (PGA) sheets were placed over the gaps between the endoclips with biopsy forceps and fixed in place with fibrin glue, completely covering the perforation site. Two days after the procedure, the perforation site had closed. Nine days later, endoscopic biliary stenting was performed. The patient was diagnosed with pancreatic cancer through bile cytology, and the optimal supportive care for her age was selected. Endoscopic tissue shielding with PGA sheets and fibrin glue is increasingly being reported for use during gastrointestinal endoscopic procedures. In this case, surgery was avoided due to successful endoscopic treatment using endoclips and PGA sheets with fibrin glue without OTSC. This method may be useful for repairing acute duodenal perforations during EUS and should therefore be known to pancreatobiliary endoscopists. (C) 2021 The Author(s) Published by S. Karger AG, Basel
引用
收藏
页码:253 / 261
页数:9
相关论文
共 50 条
  • [1] Endoscopic shielding technique using polyglycolic acid sheets with fibrin glue for perforation following endoscopic ampullectomy
    Shiomi, Hideyuki
    Masuda, Atsuhiro
    Kodama, Yuzo
    DIGESTIVE ENDOSCOPY, 2020, 32 (06) : 992 - 992
  • [2] Successful Endoscopic Closure of Gastrobronchial Fistula Using Polyglycolic Acid Sheets with Fibrin Glue
    Ando, Yoshiaki
    Setoyama, Takeshi
    Marusawa, Hiroyuki
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2023, 21 (05) : XV - XV
  • [3] Successful closure of a large perforation during colorectal endoscopic submucosal dissection by application of polyglycolic acid sheets and fibrin glue
    Sakaguchi, Yoshiki
    Tsuji, Yosuke
    Yamamichi, Nobutake
    Fujishiro, Mitsuhiro
    Koike, Kazuhiko
    GASTROINTESTINAL ENDOSCOPY, 2016, 84 (02) : 374 - 375
  • [4] Endoscopic tissue shielding with polyglycolic acid sheets, fibrin glue and clips to prevent delayed perforation after duodenal endoscopic resection
    Doyama, Hisashi
    Tominaga, Kei
    Yoshida, Naohiro
    Takemura, Kenichi
    Yamada, Shinya
    DIGESTIVE ENDOSCOPY, 2014, 26 : 41 - 45
  • [5] Successful closure of huge perforation during rectal endoscopic submucosal dissection using an endoscopic string clip suturing method and polyglycolic acid sheets and fibrin glue
    Abiko, Satoshi
    Sano, Itsuki
    Yoshikawa, Ayumu
    Harada, Kazuaki
    Kawagishi, Naoki
    Oda, Hisashi
    Miyagishima, Takuto
    ENDOSCOPY, 2022, 54 (06) : E290 - E291
  • [6] Endoscopic tissue shielding method with polyglycolic acid sheets and fibrin glue to prevent delayed perforation after duodenal endoscopic submucosal dissection
    Takimoto, Kengo
    Imai, Yoshihito
    Matsuyama, Kiichi
    DIGESTIVE ENDOSCOPY, 2014, 26 : 46 - 49
  • [7] Treating delayed perforation after esophageal endoscopic submucosal dissection using polyglycolic acid sheets and fibrin glue
    Kawata, Noboru
    Murai, Katsuyuki
    Hosotani, Kazuya
    Ono, Hiroyuki
    ENDOSCOPY, 2023, 55 : E446 - E447
  • [8] Endoscopic plombage with polyglycolic acid sheets and fibrin glue for gastrointestinal fistulas
    Nakano, Yoshiko
    Takao, Toshitatsu
    Morita, Yoshinori
    Sakaguchi, Hiroya
    Tanaka, Shinwa
    Ishida, Tsukasa
    Toyonaga, Takashi
    Umegaki, Eiji
    Kodama, Yuzo
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2019, 33 (06): : 1795 - 1801
  • [9] Endoscopic plombage with polyglycolic acid sheets and fibrin glue for gastrointestinal fistulas
    Yoshiko Nakano
    Toshitatsu Takao
    Yoshinori Morita
    Hiroya Sakaguchi
    Shinwa Tanaka
    Tsukasa Ishida
    Takashi Toyonaga
    Eiji Umegaki
    Yuzo Kodama
    Surgical Endoscopy, 2019, 33 : 1795 - 1801
  • [10] Successful endoscopic closure of a lateral duodenal perforation at ERCP with fibrin glue
    Mutignani, M
    Iacopini, F
    Dokas, S
    Larghi, A
    Familiari, P
    Tringali, A
    Costamagna, G
    GASTROINTESTINAL ENDOSCOPY, 2006, 63 (04) : 725 - 727