Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System

被引:265
|
作者
Shi, Yubing [1 ]
Lawford, Patricia [1 ]
Hose, Rodney [1 ]
机构
[1] Univ Sheffield, Fac Med Dent & Hlth, Dept Cardiovasc Sci, Med Phys Grp, Sheffield S10 2RX, S Yorkshire, England
关键词
FLUID-STRUCTURE INTERACTION; CORONARY ARTERIAL TREE; HEART-VALVE DYNAMICS; NUMERICAL-SIMULATION; MATHEMATICAL-MODEL; WAVE-PROPAGATION; VENTRICULAR INTERACTION; PULSATILE FLOW; CAROTID BAROREGULATION; ISOCAPNIC HYPOXIA;
D O I
10.1186/1475-925X-10-33
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Zero-dimensional (lumped parameter) and one dimensional models, based on simplified representations of the components of the cardiovascular system, can contribute strongly to our understanding of circulatory physiology. Zero-D models provide a concise way to evaluate the haemodynamic interactions among the cardiovascular organs, whilst one-D (distributed parameter) models add the facility to represent efficiently the effects of pulse wave transmission in the arterial network at greatly reduced computational expense compared to higher dimensional computational fluid dynamics studies. There is extensive literature on both types of models. Method and Results: The purpose of this review article is to summarise published 0D and 1D models of the cardiovascular system, to explore their limitations and range of application, and to provide an indication of the physiological phenomena that can be included in these representations. The review on 0D models collects together in one place a description of the range of models that have been used to describe the various characteristics of cardiovascular response, together with the factors that influence it. Such models generally feature the major components of the system, such as the heart, the heart valves and the vasculature. The models are categorised in terms of the features of the system that they are able to represent, their complexity and range of application: representations of effects including pressure-dependent vessel properties, interaction between the heart chambers, neuro-regulation and auto-regulation are explored. The examination on 1D models covers various methods for the assembly, discretisation and solution of the governing equations, in conjunction with a report of the definition and treatment of boundary conditions. Increasingly, 0D and 1D models are used in multi-scale models, in which their primary role is to provide boundary conditions for sophisticate, and often patient-specific, 2D and 3D models, and this application is also addressed. As an example of 0D cardiovascular modelling, a small selection of simple models have been represented in the CellML mark-up language and uploaded to the CellML model repository http://models.cellml.org/. They are freely available to the research and education communities. Conclusion: Each published cardiovascular model has merit for particular applications. This review categorises 0D and 1D models, highlights their advantages and disadvantages, and thus provides guidance on the selection of models to assist various cardiovascular modelling studies. It also identifies directions for further development, as well as current challenges in the wider use of these models including service to represent boundary conditions for local 3D models and translation to clinical application.
引用
收藏
页数:38
相关论文
共 50 条
  • [1] Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System
    Yubing Shi
    Patricia Lawford
    Rodney Hose
    BioMedical Engineering OnLine, 10
  • [2] Vibrational energy flow models for the 1-D high damping system
    Ju-Bum Han
    Suk-Yoon Hong
    Jee-Hun Song
    Hyun-Wung Kwon
    Journal of Mechanical Science and Technology, 2013, 27 : 2659 - 2671
  • [3] Vibrational energy flow models for the 1-D high damping system
    Han, Ju-Bum
    Hong, Suk-Yoon
    Song, Jee-Hun
    Kwon, Hyun-Wung
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2013, 27 (09) : 2659 - 2671
  • [4] CALIBRATION TECHNIQUE FOR 1-D UNSTEADY-FLOW MODELS
    FREAD, DL
    SMITH, GF
    JOURNAL OF THE HYDRAULICS DIVISION-ASCE, 1978, 104 (07): : 1027 - 1044
  • [5] 1-D blood flow modelling in a running human body
    Szabo, Viktor
    Halasz, Gabor
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (09) : 941 - 948
  • [6] Rational macromodeling of 1D blood flow in the human cardiovascular system
    Ferranti, Francesco
    Tamburrelli, Vincenzopio
    Antonini, Giulio
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2015, 31 (03) : 1 - 17
  • [7] 1-D MODELS FOR M-D PROCESSES
    PORTER, WA
    ARAVENA, JL
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1984, 31 (08): : 742 - 744
  • [8] 3-D convection models:: Are they compatible with 1-D models
    Nordlund, Å
    Stein, RF
    IMPACT OF LARGE-SCALE SURVEYS ON PULSATING STAR RESEARCH, 2000, 203 : 362 - 372
  • [9] Reduced modelling of blood flow in the cerebral circulation:: Coupling 1-D, 0-D and cerebral auto-regulation models
    Alastruey, J.
    Moore, S. M.
    Parker, K. H.
    David, T.
    Peiro, J.
    Sherwin, S. J.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2008, 56 (08) : 1061 - 1067
  • [10] Lumped parameter outflow models for 1-D blood flow simulations:: Effect on pulse waves and parameter estimation
    Alastruey, J.
    Parker, K. H.
    Peiro, J.
    Sherwin, S. J.
    COMMUNICATIONS IN COMPUTATIONAL PHYSICS, 2008, 4 (02) : 317 - 336