Normalizing shoulder EMG: An optimal set of maximum isometric voluntary contraction tests considering reproducibility

被引:40
|
作者
Schwartz, Cedric [1 ]
Tubez, Francois [1 ,2 ]
Wang, Francois-Charles [3 ]
Croisier, Jean-Louis [1 ,2 ]
Bruls, Olivier [1 ,4 ]
Denoel, Vincent [1 ,5 ]
Forthomme, Benedicte [1 ,2 ]
机构
[1] Univ Liege, Lab Anal Mouvement Humain, Liege, Belgium
[2] Univ Liege, Dept Phys Med & Rehabil, Liege, Belgium
[3] Univ Liege, Dept Phys Med & Sports Traumatol, Liege, Belgium
[4] Univ Liege, Dept Aerosp & Mech Engn, Liege, Belgium
[5] Univ Liege, Dept Architecture Geol Environm & Construct, Liege, Belgium
关键词
SURFACE ELECTROMYOGRAPHY; MUSCLE ACTIVATION; RELIABILITY; AMPLITUDE; ERRORS;
D O I
10.1016/j.jelekin.2017.08.005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Normalization of the electromyography (EMG) signal is often performed relatively to maximal voluntary activations (MVA) obtained during maximum isometric voluntary contraction (MVIC). The first aim was to provide an inter-session reproducible protocol to normalize the signal of eight shoulder muscles. The protocol should also lead to a level of activation > 90% of MVA for > 90% of the volunteers. The second aim was to evaluate the influence of the method used to extract the MVA from the EMG envelope on the normalized EMG signal. Thirteen volunteers performed 12 MVICs twice (one week interval). Several time constants (100 ms to 2 s) were compared when extracting the MVA from the EMG envelope. The EMG activity was also acquired during an arm elevation. Our results show that a combination of nine MVIC tests was required to meet our requirements including reproducibility. Both the number of MVIC tests and the size of the time constant influence the normalized EMG signal during the dynamic activity (variations up to 15%). A time constant of 1 s was a good compromise to extract the MVA. These findings are valuable to improve the reproducibility of EMG signal normalization.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] Normalizing gastrocnemius muscle EMG signal: An optimal set of maximum voluntary isometric contraction tests for young adults considering reproducibility
    Schwartz, Cedric
    Wang, Francois-Charles
    Forthomme, Benedicte
    Denoel, Vincent
    Bruls, Olivier
    Croisier, Jean-Louis
    GAIT & POSTURE, 2020, 82 : 196 - 202
  • [2] Standard Maximum Isometric Voluntary Contraction Tests for Normalizing Shoulder Muscle EMG
    Boettcher, Craig E.
    Ginn, Karen A.
    Cathers, Ian
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (12) : 1591 - 1597
  • [3] A comparison of two gluteus maximus EMG maximum voluntary isometric contraction positions
    Contreras, Bret
    Vigotsky, Andrew D.
    Schoenfeld, Brad J.
    Beardsley, Chris
    Cronin, John
    PEERJ, 2015, 3
  • [4] Maximum voluntary isometric contraction (MVIC)
    Cudkowicz, M
    Zhang, H
    Qureshi, M
    Schoenfeld, D
    AMYOTROPHIC LATERAL SCLEROSIS AND OTHER MOTOR NEURON DISORDERS, 2004, 5 : 84 - 85
  • [5] Determining the optimal maximal and submaximal voluntary contraction tests for normalizing the erector spinae muscles
    Bivia-Roig, Gemma
    Francisco Lison, Juan
    Sanchez-Zuriaga, Daniel
    PEERJ, 2019, 7
  • [6] Graphical User Interface to Identify Optimal Combinations of Isometric Normalization Tests for the Production of Maximum Voluntary Activation of the Shoulder Muscles
    Dal Maso, Fabien
    Marion, Patrick
    Begon, Mickael
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2016, 97 (09): : 1597 - 1598
  • [7] THEORETICAL-ANALYSIS OF SURFACE EMG IN VOLUNTARY ISOMETRIC CONTRACTION
    MIYANO, H
    SADOYAMA, T
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1979, 40 (03): : 155 - 164
  • [8] An alternative EMG normalization method: Heterogeneous recurrence quantification analysis of isometric maximum voluntary contraction movements
    Avdan, Goksu
    Chen, Cheng-Bang
    Onal, Sinan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 93
  • [9] Comparison of the Knee Extension Torque in the Maximum Voluntary Isometric Contraction and in the One Repetition Maximum Tests at Equivalent Angles
    Ferreira, Maria C. N.
    Pedrosa, Gustavo F.
    dos Santos, Marcelo D. M.
    de Souza, Barbara T. R.
    Figueiredo, Marina O. C.
    Lima, Fernando, V
    Chagas, Mauro H.
    Diniz, Rodrigo C. R.
    MLTJ-MUSCLES LIGAMENTS AND TENDONS JOURNAL, 2023, 13 (04): : 574 - 577
  • [10] Standard isometric contraction has higher reliability than maximum voluntary isometric contraction for normalizing electromyography during level walking among older adults with knee osteoarthritis
    Zhu, Xiaoxue
    Pang, Yaya
    Li, Li
    Sun, Wei
    Ding, Lijie
    Song, Qipeng
    Shen, Peixin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12