Quality of life and functional outcome after a 2-part proximal humeral fracture: A prospective cohort study on 50 patients treated with a locking plate

被引:46
|
作者
Olerud, Per [1 ]
Ahrengart, Leif [1 ]
Soderqvist, Anita [1 ]
Saving, Jenny [1 ]
Tidermark, Jan [1 ,2 ]
机构
[1] Stockholm Soder Hosp, Karolinska Inst, Dept Clin Sci & Educ, Sect Orthopaed, S-11883 Stockholm, Sweden
[2] Capio ST Gorans Hosp, Dept Orthopaed, Stockholm, Sweden
关键词
Proximal humeral fractures; internal fixation; elderly; functional outcome; quality of life; TOTAL HIP-REPLACEMENT; INTERNAL-FIXATION; CONTROLLED-TRIAL; ELDERLY-PATIENTS; FEMORAL-NECK; SHOULDER; QUESTIONNAIRE; DISABILITIES; ARM; EPIDEMIOLOGY;
D O I
10.1016/j.jse.2009.11.046
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The aim of the study was to report the 2-year outcome after a displaced 2-part fracture of the proximal humerus in elderly patients treated with a locking plate, including an assessment of the health-related quality of life (HRQoL). Material and methods: We included 50 patients, mean age 75 (range, 55-93) years with 80% women. The fracture inclusion criteria were a displacement of the shaft of >50% of its width and/or >45 degrees of angulation. Follow-up examinations were performed at 4, 12, and 24 months. The main outcome measures were the Constant and DASH scores and HRQoL according to the EQ-5D. Results: Eight patients (16%) were re-operated upon during the study period. At the final follow-up the mean Constant score was 61 and the mean DASH score 32. The EQ-5D(index) score decreased from 0.86 before the fracture to 0.62 at 4 months. At 12 months the EQ-5D(index) score was 0.65 and at 24 months 0.68. The values at all follow-ups were significantly lower than before the fracture (P < .001 in all 3 comparisons). Conclusion: Locking plates appear to be a good treatment alternative in elderly patients with a displaced 2-part fracture of the surgical neck of the proximal humerus with an acceptable complication rate and an acceptable functional outcome; however, rigorous attention has to be paid to avoid screw penetration. Despite the overall acceptable functional outcome, the patients reported a substantial negative effect upon their HRQoL. Level of evidence: Level IV, Case Series, Treatment Study. (C) 2010 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:814 / 822
页数:9
相关论文
共 50 条
  • [1] A prospective study of a new locking plate for proximal humeral fracture
    Bigorre, N.
    Talha, A.
    Cronier, P.
    Hubert, L.
    Toulemonde, J. L.
    Massin, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (02): : 192 - 196
  • [2] The influence of fracture severity on postoperative outcome and quality of life after locking plate fixation of proximal humeral fractures
    Thelen, Simon
    Grassmann, Jan P.
    Schneider, Madeleine
    Jaekel, Carina
    Meier, Dana M.
    Betsch, Marcel
    Hakimi, Mohssen
    Wild, Michael
    GMS INTERDISCIPLINARY PLASTIC AND RECONSTRUCTIVE SURGERY DGPW, 2022, 11
  • [3] Effect of Deltoid Tuberosity Index on the Outcome of Proximal Humeral Fracture Treated with a Locking Plate
    Darestani, Reza Tavakoli
    Baranzehi, Hamidreza
    Rasi, Alireza Manafi
    Omrani, Farzad Amouzadeh
    Omidian, Mohammad Mahdi
    Mirbolouk, Ahmadreza
    Baroutkoub, Mojtaba
    Sayadi, Shahram
    Barati, Hassan
    TRAUMA MONTHLY, 2021, 26 (04) : 222 - 227
  • [4] Comparative study between locking plates versus proximal humeral nail for the treatment of 2-part proximal humeral fractures
    Anna Domingo Trepat
    Dragos Popescu
    Jenaro Angel Fernández-Valencia
    Jordi Cuñé
    Moises Rios
    Salvi Prat
    European Journal of Orthopaedic Surgery & Traumatology, 2012, 22 : 373 - 379
  • [5] Comparative study between locking plates versus proximal humeral nail for the treatment of 2-part proximal humeral fractures
    Domingo Trepat, Anna
    Popescu, Dragos
    Angel Fernandez-Valencia, Jenaro
    Cune, Jordi
    Rios, Moises
    Prat, Salvi
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 (05): : 373 - 379
  • [6] THE FUNCTIONAL OUTCOME OF COMMINUTED CLOSED MIDSHAFT FRACTURE CLAVICLE TREATED WITH LOCKING COMPRESSION PLATE: A PROSPECTIVE STUDY
    Panwar, Mahendra
    Dhakad, R. K. S.
    Gupta, Sameer
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (99): : 16439 - 16443
  • [7] The association between PROMIS functional outcomes and quality of life in patients with proximal humeral fractures. A prospective cohort study
    Kobes, Tim
    Wilson, Sandra
    Hoepelman, Ruben
    Heng, Marilyn
    QUALITY OF LIFE RESEARCH, 2022, 31 : S143 - S143
  • [8] Functional outcome following one-part proximal humeral fractures: A prospective study
    Telwani, Nirmal C.
    Liporace, Frank
    Walsh, Michael
    France, Monet A.
    Zuckerman, Joseph D.
    Egol, Kenneth A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (02) : 216 - 219
  • [9] INTERNAL FIXATION WITH LOCKING PLATE OF 3-AND 4-PART PROXIMAL HUMERAL FRACTURES IN ELDERLY PATIENTS: COMPLICATIONS AND FUNCTIONAL OUTCOME
    Matejcic, Aljosa
    Vidovic, Dinko
    Ivica, Mihovil
    Durdevic, Dragan
    Tomljenovic, Mladen
    Bekavac-Beslin, Miroslav
    Mijic, August
    Punda, Marija
    Bakota, Bore
    Misir, Zvonimir
    ACTA CLINICA CROATICA, 2013, 52 (01) : 17 - 22
  • [10] FUNCTIONAL OUTCOME OF SCHATZKER TYPE 5 AND 6 TIBIAL PLATEAU FRACTURE TREATED BY PROXIMAL LOCKING PLATE
    Srinivas, Chatla
    Satish, Parupalli
    Murthy, G. V. S.
    Raju, B.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2018, 7 (48): : 5141 - 5144