Impact of the Lok-bar for High-precision Radiotherapy with Tomotherapy

被引:2
|
作者
Hirata, Makoto [1 ]
Monzen, Hajime [1 ]
Tamura, Mikoto [1 ,2 ]
Kubo, Kazuki [1 ,3 ]
Matsumoto, Kenji [1 ,2 ]
Hanaoka, Kohei [1 ,2 ]
Okumura, Masahiko [2 ]
Nishimura, Yasumasa [4 ]
机构
[1] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, 377-2 Ohno Higashi, Osakasayama, Osaka 5898511, Japan
[2] Kindai Univ Hosp, Dept Cent Radiol, Osaka, Japan
[3] Tane Gen Hosp, Dept Radiat Oncol, Osaka, Japan
[4] Kindai Univ, Fac Med, Dept Radiat Oncol, Osaka, Japan
关键词
Artifacts; immobilizer; lok-bar; tomotherapy; HELICAL TOMOTHERAPY; RADIATION-THERAPY; IRRADIATION; ABSORPTION;
D O I
10.21873/anticanres.12515
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background/Aim: Patient immobilization systems are used to establish a reproducible patient position relative to the couch. In this study, the impact of conventional lokbars for CT-simulation (CIVCO-bar) and treatment (iBEAMbar) were compared with a novel lok-bar (mHM-bar) in tomotherapy. Materials and Methods: Verification was obtained as follows: i. artifacts in CT images; ii. dose attenuation rate of lok-bar, compared to without lok-bar; and iii. dose differences between the calculated and measured absorbed doses. Results: With the CIVCO-bar, there were obvious metal artifacts, while there were nearly no artifacts with the mHM-bar. The mean dose attenuation rates with the mHM-bar and iBEAM-bar were 1.31% and 2.28%, and the mean dose difference was 1.55% and 1.66% for mHM-bar and iBEAM-bar. Conclusion: Using the mHM-bar reduced artifacts on the CT image and improved dose attenuation are obtained. The lok-bar needs to be inserted as a structure set in treatment planning with tomotherapy.
引用
收藏
页码:2733 / 2738
页数:6
相关论文
共 50 条
  • [1] Evolution of radiotherapy: High-precision radiotherapy
    Kim, Yong Bae
    Suh, Chang-Ok
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2008, 51 (07): : 604 - 611
  • [2] Imaging for high-precision thoracic radiotherapy
    Senthi, Sashendra
    Senan, Suresh
    JOURNAL OF THORACIC DISEASE, 2012, 4 (02) : 106 - 108
  • [3] A high-precision system for conformal intracranial radiotherapy
    Tomé, WA
    Meeks, SL
    Buatti, JM
    Bova, FJ
    Friedman, WA
    Li, ZF
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04): : 1137 - 1143
  • [4] High-precision external radiotherapy of brain tumors
    Becker, G
    Kortmann, RD
    Duffner, F
    Budach, W
    Buchgeister, M
    Grote, EH
    Bamberg, M
    ONKOLOGIE, 1998, 21 (04): : 290 - 297
  • [5] MANUFACTURE OF HIGH-PRECISION WORKPIECES BY GRINDING FROM THE BAR
    WALTI, W
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1985, 93 (02): : 57 - 59
  • [6] High-precision radiotherapy for craniospinal irradiation: evaluation of three-dimensional conformal radiotherapy, intensity-modulated radiation therapy and helical TomoTherapy
    Sharma, D. S.
    Gupta, T.
    Jalali, R.
    Master, Z.
    Phurailatpam, R. D.
    Sarin, R.
    BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (984): : 1000 - 1009
  • [7] Imaging science and development in modern high-precision radiotherapy
    Thorwarth, Daniela
    Muren, Ludvig
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 12 : 63 - 66
  • [8] Spinal cord constraints in the era of high-precision radiotherapy
    Zschaeck, Sebastian
    Wust, Peter
    Graf, Reinhold
    Wlodarczyk, Waldemar
    Schild, Reinhard
    Thieme, Alexander Henry
    Weihrauch, Mirko
    Budach, Volker
    Ghadjar, Pirus
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 (07) : 561 - 569
  • [9] Hidden point bar method for high-precision industrial surveys
    Teskey, WF
    Paul, B
    Teskey, WJ
    JOURNAL OF SURVEYING ENGINEERING-ASCE, 2005, 131 (04): : 103 - 106
  • [10] Manufacture of High-Precision Workpieces by Grinding from the Bar.
    Waelti, Werner
    1600, (93):