Dose evaluation of organs at risk (OAR) cervical cancer using dose volume histogram (DVH) on brachytherapy

被引:1
|
作者
Wibowo, R. Arif [1 ]
Haris, Bambang [2 ]
Islamiyah, Inganatul
机构
[1] Airlangga Univ, Fac Sci & Technol, Dept Phys, Campus C Mulyorejo, Surabaya, Indonesia
[2] Dr Soetomo Hosp, Dept Radiotherapy, Surabaya, Indonesia
关键词
INTRACAVITARY; RECOMMENDATIONS; PARAMETERS;
D O I
10.1088/1742-6596/853/1/012013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Brachytherapy is one way to cure cervical cancer. It works by placing a radioactive source near the tumor. However, there are some healthy tissues or organs at risk (OAR) such as bladder and rectum which received radiation also. This study aims to evaluate the radiation dose of the bladder and rectum. There were 12 total radiation dose data of the bladder and rectum obtained from patients' brachytherapy. The dose of cervix for all patients was 6 Gy. Two-dimensional calculation of the radiation dose was based on the International Commission on Radiation Units and Measurements (ICRU) points or called DICRU while the 3-dimensional calculation derived from Dose Volume Histogram (DVH) on a volume of 2 cc (D-2cc). The radiation dose of bladder and rectum from both methods were analysed using independent t test. The mean DICRU of bladder was 4.33730 Gy and its D2cc was4.78090 Gy. DICRU and D2cc bladder did not differ significantly (p = 0.144). The mean DICRU of rectum was 3.57980 Gy and 4.58670 Gy for D2cc. The mean DICRU of rectum differed significantly from D2cc of rectum (p = 0.000). The three-dimensional method radiation dose of the bladder and rectum was higher than the two-dimensional method with ratios 1.10227 for bladder and 1.28127 for rectum. The radiation dose of the bladder and rectum was still below the tolerance dose. Two-dimensional calculation of the bladder and rectum dose was lower than three-dimension which was more accurate due to its calculation at the whole volume of the organs.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Dose-volume histogram (DVH) analysis of organs at risk for intracavitary brachytherapy of cervical cancer: Compared to ICRU 38 reference dose
    Kim, RY
    Pareek, PN
    [J]. RADIOLOGY, 2002, 225 : 598 - 598
  • [2] Treatment plan evaluation using dose-volume histogram (DVH) and spatial dose-volume histogram (zDVH)
    Cheng, CW
    Das, IJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (05): : 1143 - 1150
  • [3] Optimum organ volume ranges for organs at risk dose in cervical cancer intracavitary brachytherapy
    Siavashpour, Zahra
    Aghamiri, Mahmoud Reza
    Jaberi, Ramin
    Manshadi, Hamid Reza Dehghan
    Ghaderi, Reza
    Kirisits, Christian
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (02) : 135 - 142
  • [4] EVALUATION OF BRACHYTHERAPY IMPLANTS USING THE NATURAL VOLUME DOSE HISTOGRAM
    VANTRIET, A
    TELOO, HJ
    MAK, ACA
    VEEN, RE
    YPMA, AFGVM
    BOS, J
    HOEKSTRA, CJM
    KROESE, MCS
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 26 (01) : 82 - 84
  • [5] Analysis of Volume Based GYN HDR Brachytherapy Plans for Dose Calculation to Organs At Risk(OAR)
    Nair, M.
    Li, C.
    White, M.
    Davis, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 374 - +
  • [6] Evaluation of variation in dose of organs at risk in intracavitary brachytherapy of cervical cancer - a prospective study
    Sharma, Brahmacharimayum Arunkumar
    Singh, Tomcha
    Singh, L. Jaichand
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2011, 3 (01) : 23 - 25
  • [7] OAR Dose Tolerance Recommendations for Prostate and Cervical HDR Brachytherapy: Dose Versus Volume Metrics
    Geneser, S.
    Cunha, J.
    Pouliot, J.
    Hsu, I.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 91 - 91
  • [8] Dependence of the dose volume histogram (DVH) of a risk structure of Drawing.
    Link, K.
    Duma, M. N.
    Theodorou, M.
    Ertel-Pobianski, E.
    Kampfer, S.
    Molls, M.
    Geinitz, H.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 16 - 16
  • [9] Independent Evaluation Of Dose-Volume Histogram (Dvh) Calculation Accuracy
    Moragues Femenia, S.
    Calvo-Ortega, J. F.
    Casals, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S465 - S465
  • [10] Dose volume histogram analysis of MRI-based intracavitary pulsed dose rate brachytherapy in cervical cancer
    Lindegaard, J.
    Tanderup, K.
    Gelineck, J.
    Nielsen, S. K.
    Christensen, J. J.
    Christensen, T. B.
    Nyvang, G-B.
    Jurik, A. G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S78 - S78