Optical coherence tomography-based continuous noninvasive glucose monitoring in patients with diabetes

被引:41
|
作者
Gabbay, Robert A. [1 ]
Sivarajah, Surendra [1 ]
机构
[1] Penn State Univ, Milton S Hershey Med Ctr, Coll Med, Penn State Inst Diabet & Obes, Hershey, PA 17033 USA
关键词
D O I
10.1089/dia.2007.0277
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The objective of this feasibility study was to test an optical coherence tomography (OCT)-based system for noninvasive, accurate, and continuous monitoring of blood (as opposed to interstitial) glucose concentration in subjects with diabetes. OCT uses low coherence light with precise depth focusing ability to measure changes in the microvasculature structure for glucose detection. Research Design and Methods: Thirty-three subjects with diabetes had blood glucose concentrations evaluated using simultaneous capillary and OCT-based device (Sentris-100 (TM), GlucoLight, Bethlehem, PA) measurements. Subjects received a 50-g carbohydrate load at the start of the study period. Two glucose values with 60 mg separation were used to calibrate the OCT system. Six subjects were excluded (two because of hardware and/or software failures at study initiation, two because of sensor connection problems, and two others because of problems with disposable device positioning on the skin). Of the 27 subjects who completed the study, 12 had type I diabetes, and 15 had type 2 diabetes. Statistical analysis included plotting of the Clarke error grid, comparison to International Organization for Standardization (ISO) standards for glucose monitoring systems, and calculation of the Pearson correlation coefficient. Results: Based on a total of 236 matched points, Clarke error grid analysis indicated 83% in zone A, 16% in zone B, and < 1% in zones C and D. ISO standards comparison showed 83% of OCT estimates were within 20% of the reference value for blood glucoses > 75 mg/dL. No conclusions can be made about blood glucose estimates in the < 75 mg/dL range since no low reference, values occurred. The Pearson correlation coefficient comparing OCT versus capillary blood glucose was 0.85 (95% confidence interval 0.81-0.88, P < 0.0001). Mean relative absolute deviation was 11.5%, and median relative absolute deviation was 8.2%. Conclusions: This study demonstrated that the OCT system shows acceptable accuracy in the prediction of blood glucose levels in subjects with both type 1 and type 2 diabetes. Future efforts will evaluate the accuracy of the system in the hypoglycemic range.
引用
收藏
页码:188 / 193
页数:6
相关论文
共 50 条
  • [1] Optical coherence tomography-based continuous non-invasive glucose monitoring in patients with diabetes
    Gabbay, Robert
    Sivarajah, Surendra
    Wilkins, Robert
    Schurman, Matthew
    [J]. DIABETES, 2007, 56 : A108 - A108
  • [2] Noninvasive monitoring of glucose concentration with optical coherence tomography
    Esenaliev, RO
    Larin, KV
    Larina, IV
    Motamedi, M
    [J]. OPTICS LETTERS, 2001, 26 (13) : 992 - 994
  • [3] Noninvasive monitoring of blood glucose concentration in diabetic patients with optical coherence tomography
    Lan, Y. T.
    Kuang, Y. P.
    Zhou, L. P.
    Wu, G. Y.
    Gu, P. C.
    Wei, H. J.
    Chen, K.
    [J]. LASER PHYSICS LETTERS, 2017, 14 (03)
  • [4] Specificity of noninvasive blood glucose monitoring with optical coherence tomography
    Larin, KV
    Ashitkov, TV
    Motamedi, M
    Esenaliev, RO
    [J]. OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III, 2003, 4965 : 25 - 31
  • [5] Optical Coherence Tomography-based Intraocular Pressure Monitoring Principle
    Min, Kyung-Pyo
    Kim, Dae Yu
    Kim, Gi-Woo
    [J]. NANO-, BIO-, INFO-TECH SENSORS, AND 3D SYSTEMS IV, 2020, 11378
  • [6] The studies of noninvasive blood glucose monitoring using optical coherence tomography
    Li Ran
    Liu Guozhong
    Hu Zhixiong
    Xia Xiaopeng
    Liu Tao
    [J]. 9TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES (AOMATT 2018): OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2019, 10839
  • [7] In vitro studies toward noninvasive glucose monitoring with optical coherence tomography
    Kinnunen, M
    Myllylä, R
    Jokela, T
    Vainio, S
    [J]. APPLIED OPTICS, 2006, 45 (10) : 2251 - 2260
  • [8] Application of optical coherence tomography for noninvasive blood glucose monitoring during hyperglycemia
    Larin, KV
    Ashitkov, TV
    Motamedi, M
    Esenaliev, RO
    [J]. SARATOV FALL MEETING 2002: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE IV, 2002, 5068 : 294 - 298
  • [9] COMPENSATION OF THERMAL EFFECT ON NONINVASIVE BLOOD GLUCOSE MONITORING IN OPTICAL COHERENCE TOMOGRAPHY
    Amrane, Said
    Azami, Nawfel
    Abouricha, Mostafa
    [J]. JOURNAL OF SCIENCE AND ARTS, 2016, (04): : 377 - 384
  • [10] Automated Monitoring for Optical Coherence Tomography-based Biosensing Using Deep Learning
    Kim, Heejong
    Yu, Chun-Nam
    Kennedy, William
    Eggleston, Michael
    Shah, Shreyas
    [J]. 2020 IEEE PHOTONICS CONFERENCE (IPC), 2020,