Performance evaluation of Coriolis mass flow meter in laminar flow regime

被引:7
|
作者
Kolhe, Vikram A. [1 ]
Edlabadkar, Ravindra L. [2 ]
机构
[1] Amrutvahini Coll Engn, Dept Mech Engn, Sangamner 422608, Maharashtra, India
[2] Pune Vidyarthi Grihas Coll Engn, Dept Mech Engn, Nasik 422004, Maharashtra, India
关键词
Coriolis mass flow meter; Tube configuration; Drive frequency; Amplitude of vibration; Sensor position; Laminar flow regime; FLOWMETER;
D O I
10.1016/j.flowmeasinst.2020.101837
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In many fluid flow applications, mass flow rate is preferred over volume flow rate, as it is more beneficial in terms of cost and material balance calculations. Coriolis mass flow meter (CMFM) is accepted widely for mass flow measurement owing to its accuracy and reliability. However, it has been found to under-read the mass flow rate in laminar flow region [1], thus limiting its application in this region. The secondary flow in the curved tube section influences the generated Coriolis force and leads to a deviation in meter readings. Commercial CMFMs are available with various curved tube configurations and need to be analyzed for their application in laminar region. This paper presents comprehensive experimental and numerical investigations performed to evaluate the influence of tube configuration and other meter parameters, such as drive frequency, amplitude of vibration, and sensor position, on the performance of the CMFM in laminar region. The findings of this study have put forth a suitable combination of tube configuration, drive frequency, and sensor position while using the CMFM in laminar flow regime.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Evaluation of omega-shaped coriolis mass flow meter for laminar flow
    Kolhe V.A.
    Pawar S.Y.
    Chaudhari V.D.
    Edlabadkar R.L.
    Chandratre K.V.
    Journal of Computational and Applied Research in Mechanical Engineering, 2024, 13 (02): : 181 - 190
  • [2] Parameter optimization of coriolis mass flow meter in laminar flow regime using Doe-Taguchi method
    Kolhe, Vikram
    Pawar, Suyash
    Chaudhari, Vishal
    Edlabadkar, Ravindra
    Sonawane, Sandipkumar
    JOURNAL OF THERMAL ENGINEERING, 2023, 9 (04): : 1026 - 1040
  • [3] Response of a Coriolis mass flow meter to step changes in flow rate
    Henry, MP
    Clark, C
    Duta, M
    Cheesewright, R
    Tombs, M
    FLOW MEASUREMENT AND INSTRUMENTATION, 2003, 14 (03) : 109 - 118
  • [4] Compact Mass Flow Meter Based on a Micro Coriolis Flow Sensor
    Sparreboom, Wouter
    van de Geest, Jan
    Katerberg, Marcel
    Postma, Ferry
    Haneveld, Jeroen
    Groenesteijn, Jarno
    Lammerink, Theo
    Wiegerink, Remco
    Lotters, Joost
    MICROMACHINES, 2013, 4 (01): : 22 - 33
  • [5] Experimental study on dynamic performance of coriolis mass flow meter and compensation technology
    Dezhi Zheng
    Qiong Nan
    Jiying Shi
    Shangchun Fan
    Instruments and Experimental Techniques, 2012, 55 : 503 - 507
  • [6] Air! - Coriolis mass flow meter in an alarm state
    Goeke, Johannes
    Stock, Marc
    Steffensen, Erk
    ATP EDITION, 2008, (03): : 46 - 50
  • [7] NE 132 Coriolis-Mass Flow Meter
    不详
    ATP EDITION, 2009, (07): : 13 - 13
  • [8] Experimental study on dynamic performance of coriolis mass flow meter and compensation technology
    Zheng, Dezhi
    Nan, Qiong
    Shi, Jiying
    Fan, Shangchun
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2012, 55 (04) : 503 - 507
  • [9] The performance characteristics of a micro-machined Coriolis flow meter: An evaluation by simulation
    Clark, C.
    Wang, S.
    Cheesewright, R.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (06) : 325 - 333
  • [10] ADVANCED PHASOR CONTROL OF A CORIOLIS MASS FLOW METER (CMFM)
    Roeck, H.
    Koschmieder, F.
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 1344 - 1349