Discontinuous sets of knee extensions induce higher cardiovascular responses in comparison to continuous ones

被引:9
|
作者
Polito, Marcos Doederlein [1 ]
Simao, Roberto [2 ]
Lira, Vitor Agnew [5 ]
Lucas da Nobrega, Antonio Claudio [3 ]
Veras Farinatti, Paulo de Tarso [4 ]
机构
[1] Univ Estadual Londrina, Ctr Educ Fis & Esporte, Dept Educ Fis, BR-86051990 Londrina, Parana, Brazil
[2] Univ Fed Rio de Janeiro, Rio De Janeiro, Brazil
[3] Univ Fed Fluminense, Niteroi, RJ, Brazil
[4] Univ Estado Rio de Janeiro, BR-20550011 Rio De Janeiro, Brazil
[5] Univ Florida, Coll Hlth & Human Performance, Gainesville, FL 32611 USA
关键词
blood pressure; heart rate; photoplethysmography; muscle strength;
D O I
10.1590/S0066-782X2008000600001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The strength training can promote significant cardiovascular responses (luring its performance and it is interesting to devise strategies to reduce them, without compromising the strength production. Objective: To compare the acute cardiovascular responses of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), heart rate (HR) and double product (DP) during the unilateral knee extension (four series of 8 maximum repetitions) performed continuously or discontinuously. Both protocols involved a 2-minute interval between the series and the discontinuous protocol had an extra interval of 2 seconds between the 4(th) and the 5(th) repetitions. Methods: Eight healthy men trained in muscular strength (aged 26 6 years) participated in the data collection and were randomly divided in two non-consecutive days. The cardiovascular responses were measured by photoplethysmography (Finapres, Ohmeda, Louisville, CO US, V at rest, at the end of each series and 2 minutes after the performance of each protocol. Results: The discontinuous series showed significantly higher values when compared to the protocol of the continuous series for: SAP (mmHg) at the 2(nd) (73.1 +/- 5.4 vs 1520 +/- 4.0; p=0.001), 3(rd) (188.9 +/- 8.6 v.s 162.4 +/- 6.0; p=0.000) and 4(th) series (793.1 +/- 8.1 vs 161.6 +/- 5.9; p=0.000); DAP (mmHg) at the 3(rd) (103.8 +/- 4.1 vs 86.7 +/- 3.3; p=0.000) and 4(th) series (104.1 +/- 2.7 vs 83.4 +/- 3.3; p=0.000); DP (mmHg.bpm) at the 2(nd) (17,907.5 +/- 1,350.7 vs 14,541.9 +/- 1,848.0; p=0.03), 3(rd) (19,687.3 +/- 1,444.3 vs 15,612.1 +/- 1,180.3;p=0.008) and 4(th) series (21,271 +/- 1,794.2 vs 15,992.0 +/- 1,093.4; p=0.001). Conclusion: The discontinuous protocol promoted higher increase in pressure responses when compared to the continuous one. However, due to the characteristics of the study design, further studies are necessary to support these findings.
引用
收藏
页码:382 / 387
页数:6
相关论文
共 5 条
  • [1] Cardiovascular Responses To Aerobic Exercise With Continuous And Discontinuous Blood Flow Restriction
    Brown, James
    Lauver, Jakob D.
    Guilkey, Justin P.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 350 - 351
  • [2] RESPONSES OF SUBJECTS WITH SPINAL-CORD INJURIES TO MAXIMAL WHEELCHAIR EXERCISE - COMPARISON OF DISCONTINUOUS AND CONTINUOUS PROTOCOLS
    RASCHE, W
    JANSSEN, TWJ
    VANOERS, CAJM
    HOLLANDER, AP
    VANDERWOUDE, LHV
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1993, 66 (04): : 328 - 331
  • [3] Comparison of three catheter sets for continuous spinal anesthesia in patients undergoing total hip or knee arthroplasty
    Puolakka, R
    Pitkänen, MT
    Rosenberg, PH
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2000, 25 (06) : 584 - 590
  • [4] Computer-mediated communication and time pressure induce higher cardiovascular responses in the preparatory and execution phases of cooperative tasks
    Costa Ferrer, Raquel
    Serrano Rosa, Miguel Angel
    Zornoza Abad, Ana
    Salvador Fernandez-Montejo, Alicia
    PSICOTHEMA, 2010, 22 (04) : 697 - 702
  • [5] Evaluation and comparison of sideband harmonics and acoustic responses with continuous and discontinuous PWM strategies in permanent magnet synchronous motor for electric vehicles
    Qiu, Zizhen
    Chen, Yong
    Liu, Xu
    Zhang, Liming
    Cheng, Haiquan
    INTERNATIONAL JOURNAL OF HYDROMECHATRONICS, 2022, 5 (02) : 109 - 123