Decrease in Tear Film Lipid Layer Thickness in Patients with Keratoconus

被引:2
|
作者
Zhou, Wenyan [1 ]
Yu, Haozhe [1 ,2 ]
Feng, Yun [1 ,2 ]
机构
[1] Peking Univ Third Hosp, Dept Ophthalmol, Beijing 100191, Peoples R China
[2] Peking Univ Hlth Sci Ctr, Inst Med Technol, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
lipid layer thickness; keratoconus; tear film; partial blink; dry eye; meibomian glands; POSTERIOR CORNEAL ASTIGMATISM; DRY EYE; SYMPTOMS; PATTERNS;
D O I
10.3390/jcm11185252
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Keratoconus (KC) is a progressive corneal disorder characterized by thinning and protrusion, mostly of the inferotemporal and central corneal regions. Dysfunction of the meibomian gland, the excretions of which form the lipid layer of the tear film, has been reported to be associated with KC. Thus, this manuscript investigates the correlation among lipid layer thickness (LLT), partial blink rate (PBR), and KC of different degrees. This retrospective study included 54 patients and 24 healthy controls. The anterior corneal curvature, LLT, and PBR were taken from the unilateral eye of all 78 participants. The difference in those ocular parameters between the moderate and severe groups and the control group is significant. No significant association was found between anterior corneal curvature and LLT (r = -0.2, p = 0.15) across all the patients. However, there was a significant negative correlation between anterior corneal curvature and LLT in moderate (r = -0.6, p < 0.05) and severe (r = -0.7, p < 0.05) keratoconus cases. The results also show a significant negative correlation between anterior corneal curvature and PBR (r = -0.41, p < 0.05). Therefore, we conclude that the severity of keratoconus is associated with the thinning of LLT and the reduction of PBR. This may relate to a further epithelial abnormality with the reduced protection of tear film from the air, leading to the release of proteolytic enzymes that degrade stromal collagen and weaken the cornea.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] TEAR FILM LIPID LAYER THICKNESS AS A FUNCTION OF BLINKING
    KORB, DR
    BARON, DF
    HERMAN, JP
    FINNEMORE, VM
    EXFORD, JM
    HERMOSA, JL
    LEAHY, CD
    GLONEK, T
    GREINER, JV
    [J]. CORNEA, 1994, 13 (04) : 354 - 359
  • [2] Lipid layer thickness decrease due to meibomian gland dysfunction leads to tear film instability and reflex tear secretion
    Kim, Wung Jae
    Ahn, Ye Jin
    Kim, Min Ho
    Kim, Hyun Seung
    Kim, Man Soo
    Kim, Eun Chul
    [J]. ANNALS OF MEDICINE, 2022, 54 (01) : 893 - 899
  • [3] Tear Lipid Layer Thickness and Variability Both Impact Tear Film Stability
    Lin, Meng C.
    Graham, Andrew D.
    Satjawatcharaphong, Pam
    Li, Wing
    Yeh, Thao N.
    Lerma, Mariel
    Lin, Kristina
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [4] Tear film lipid layer visualization and tear film decrease rate quantification using ultrahigh resolution OCT
    dos Santos, Valentin Aranha
    Schmetterer, Leopold
    Garhofer, Gerhard
    Werkmeister, Rene Marcel
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [5] Effect of meibomian gland occlusion on tear film lipid layer thickness
    Greiner, JV
    Glonek, T
    Korb, DR
    Hearn, SL
    Whalen, AC
    Esway, JE
    Leahy, CD
    [J]. LACRIMAL GLAND, TEAR FILM, AND DRY EYE SYNDROMES 2: BASIC SCIENCE AND CLINICAL RELEVANCE, 1998, 438 : 345 - 348
  • [6] Factors Influencing the Measurement of Tear Film Lipid Layer Thickness with Interferometry
    Finis, D.
    Pischel, N.
    Borrelli, M.
    Schrader, S.
    Geerling, G.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2014, 231 (06) : 603 - 610
  • [7] More to Stable Tears Than Thickness of the Tear Film Lipid Layer
    Fenner, Beau J.
    Tong, Louis
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (03) : 1601 - 1601
  • [8] Evaluation of factors affecting the tear-film lipid layer thickness
    Kim, Tae-im
    Park, Si Yoon
    Jung, Ji Won
    Seo, Kyoung Yul
    Lee, Hun
    Ji, Yong Woo
    Kim, Eung Kweon
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [9] Assessment of the Tear Film Lipid Layer Thickness after Cataract Surgery
    Kim, Jin Sun
    Lee, Hun
    Choi, Seonghee
    Kim, Eung Kweon
    Seo, Kyoung Yul
    Kim, Tae-Im
    [J]. SEMINARS IN OPHTHALMOLOGY, 2018, 33 (02) : 231 - 236
  • [10] In vivo thickness measurement of the lipid layer and the overall tear film by interferometry
    Bai, Yuqiang
    Nichols, Jason J.
    [J]. OPTICS LETTERS, 2019, 44 (10) : 2410 - 2413