Band-Averaged Response Sensitivity Study of an Imaging Spectrometer for the CLARREO Pathfinder Mission

被引:1
|
作者
Salehi, Fatholah [1 ]
Thome, Kurtis [2 ]
Wenny, Brian N. [1 ]
Lockwood, Ronald [3 ]
Wang, Zhipeng [1 ]
机构
[1] Sci Syst & Applicat Inc, Lanham, MD 20706 USA
[2] NASA, Sci & Explorat Directorate, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
[3] MIT, Lincoln Lab, Lexington, MA 02421 USA
关键词
CLARREO Pathfinder; radiometric calibration; SI-traceable; hyperspectral imaging; remote sensing; image processing; RADIOMETRIC CALIBRATION;
D O I
10.3390/rs14102302
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Prelaunch absolute, SI-traceable radiometric calibration of satellite-based sensors is key to ensuring the utility of imaging spectrometer-based data products. The development of detector-based calibration techniques leads to the feasibility of meeting the 0.3% uncertainty level needed to provide climate quality data sets. Detector-based calibration is a method in which a well-understood and stable transfer radiometer is calibrated in a standards laboratory to SI-traceable standards, and transported to a facility calibrating a sensor of interest. The transfer radiometer provides the calibration of the source used in the radiometric calibration. A detector-based calibration approach is part of the prelaunch calibration of the CLARREO (Climate Absolute Radiance and Refractivity Observatory) Pathfinder (CPF) sensor with the Goddard Laser for Absolute Measurement of Radiance (GLAMR) system. The SI-traceability of GLAMR is through the electric watt as part of the absolute radiometric calibration of the detectors at the National Institute of Standards and Technology using the Primary Optical Watt Radiometer. The current work uses GLAMR data collected with a visible and near-infrared imaging spectrometer calibration demonstration system to develop a source/sensor modeled calibration data set as part of a sensitivity study to evaluate uncertainties from the spectral sampling and processing methods that accompany the GLAMR calibration process. The spectral "supersets" include realistic instrumental features as well as effects from the GLAMR source. The methods needed to ensure that spurious sensor and GLAMR data are excluded are described. Results are given from the sensitivity study related to GLAMR spectral sampling and signal-to-noise ratio (SNR) effects, sensor integration time, and frame averaging of the imaging spectrometer data. The study shows that the 6 nm bandwidth sensor simulation requires a 1 nm spectral sampling of the GLAMR source with a radiance level that provides an in-band peak SNR > 200 to ensure that climate quality accuracies can be achieved. The results are also used to refine the test plan for the independent calibration for the CLARREO Pathfinder sensor calibration to optimize test time while meeting the required accuracy levels.
引用
收藏
页数:17
相关论文
共 6 条
  • [1] Detector Based Calibration of a Portable Imaging Spectrometer for CLARREO Pathfinder Mission
    Aytac, Yigit
    Thome, Kurt
    Wenny, Brian N.
    Angal, Amit
    Shuman, Timothy M.
    McAndrew, Brendan
    [J]. EARTH OBSERVING SYSTEMS XXIV, 2019, 11127
  • [2] Sensitivity Analysis Method for Spectral Band Adjustment between Hyperspectral Sensors: A Case Study Using the CLARREO Pathfinder and HISUI
    Obata, Kenta
    [J]. REMOTE SENSING, 2019, 11 (11)
  • [3] Cross-frequency and band-averaged response variance prediction in the hybrid deterministic-statistical energy analysis method
    Reynders, Edwin P. B.
    Langley, Robin S.
    [J]. JOURNAL OF SOUND AND VIBRATION, 2018, 428 : 119 - 146
  • [4] The Effects of VIIRS Detector-Level and Band-Averaged Relative Spectral Response Differences Between S-NPP and NOAA-20 on the Thermal Emissive Bands
    Lin, Lin
    Cao, Changyong
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2019, 12 (10) : 4123 - 4130
  • [5] Surface Biology and Geology imaging spectrometer: A case study to optimize the mission design using intrinsic dimensionality
    Cawse-Nicholson, K.
    Raiho, A. M.
    Thompson, D. R.
    Hulley, G. C.
    Miller, C. E.
    Miner, K. R.
    Poulter, B.
    Schimel, D.
    Schneider, F. D.
    Townsend, P. A.
    Zareh, S. K.
    [J]. REMOTE SENSING OF ENVIRONMENT, 2023, 290
  • [6] Authors' response to comment on "Evaluation of the sensitivity, specificity, positive and negative predictive values of preoperative magnetic resonance imaging for staging endometrial cancer. A prospective study of 100 cases at the Dorset Cancer Centre" [Eur. J. Obstet. Gynecol. Reprod. Biol., in press]
    Ortashi, Osman
    [J]. EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2008, 137 (01): : 117 - 117