Role of duplex Doppler sonography in diagnosis of acute allograft dysfunction-time to stop measuring the resistive index?

被引:24
|
作者
Dupont, PJ
Dooldeniya, M
Cook, T
Warrens, AN
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp NHS Trust, Dept Immunol, London W12 0NN, England
[2] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp NHS Trust, Dept Renal Med, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp NHS Trust, Dept Pathol, London, England
关键词
renal transplantation; rejection; resistive index; duplex Doppler sonography;
D O I
10.1007/s00147-003-0601-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Measurement of vascular resistive index (RI) by duplex Doppler sonography (DDS) has been proposed as a non-invasive technique to detect the presence of acute rejection in renal allograft recipients. Our aim was to evaluate the clinical utility of this technique. From 107 patients we reviewed 159 biopsies that were performed from 1993 to 2001 for the investigation of acute allograft dysfunction. Histological findings were correlated with RI measurements by contemporaneously performed DDS. The majority of biopsies were carried out within the first 3 months post-transplantation (111/159). Sixty-eight biopsies showed acute rejection, 91 biopsies had findings other than rejection (acute tubular necrosis, CyA toxicity, recurrent GN). Using a threshold mean RI value of 0.9, the test had a specificity for acute rejection of 89%, but a sensitivity of just 6%. If the threshold was lowered the sensitivity rose, but specificity declined sharply. Average RI in the rejection group was not higher than in controls (0.73+/-0.11 vs 0.74+/-0.11, respectively). We conclude that measurement of RI by DDS does not contribute to the diagnosis of acute allograft dysfunction.
引用
收藏
页码:648 / 652
页数:5
相关论文
共 34 条
  • [1] USEFULNESS OF DUPLEX DOPPLER SONOGRAPHY IN THE DIAGNOSIS OF ACUTE RENAL-ALLOGRAFT REJECTION
    MONTSERRAT, E
    LAUZURICA, R
    VALLS, R
    PEREZANDRES, R
    TORGUET, P
    TENESA, M
    CARALPS, A
    TRANSPLANTATION PROCEEDINGS, 1992, 24 (01) : 61 - 62
  • [2] Resistive index on renal duplex Doppler sonography in hypertensive patients with NIDDM
    Hosojima, H
    Miyauchi, E
    Morimoto, S
    DIABETES, 1996, 45 : 12 - 12
  • [3] Potential role of duplex Doppler sonography in acute renal colic
    Roy, C
    Tuchmann, C
    Pfleger, D
    Guth, S
    Saussine, C
    Jacqmin, D
    JOURNAL OF CLINICAL ULTRASOUND, 1998, 26 (09) : 427 - 432
  • [4] Value of resistive index in the diagnosis of liver tumors with duplex Doppler ultrasonography
    Wang, W
    Wang, Y
    Ding, H
    Xu, Z
    RADIOLOGY, 2002, 225 : 122 - 122
  • [6] Doppler sonography in the diagnosis of antepartum pyelonephritis: Value of intrarenal resistive index measurements
    Keogan, MT
    Hertzberg, BS
    Kliewer, MA
    DeLong, DM
    Paulson, EK
    Carroll, BA
    JOURNAL OF ULTRASOUND IN MEDICINE, 1996, 15 (01) : 13 - 17
  • [7] DUPLEX DOPPLER ULTRASOUND IN THE DIAGNOSIS OF ACUTE RENAL-ALLOGRAFT REJECTION
    WAN, SKH
    FERGUSON, CJ
    COCHLIN, DL
    EVANS, C
    GRIFFITHS, DFR
    CLINICAL RADIOLOGY, 1989, 40 (06) : 573 - 576
  • [8] DIAGNOSIS OF FUNCTIONAL KIDNEY FAILURE OF CIRRHOSIS WITH DOPPLER SONOGRAPHY - PROGNOSTIC VALUE OF RESISTIVE INDEX
    MAROTO, A
    GINES, A
    SALO, J
    CLARIA, J
    GINES, P
    ANIBARRO, L
    JIMENEZ, W
    ARROYO, V
    RODES, J
    HEPATOLOGY, 1994, 20 (04) : 839 - 844
  • [9] ACUTE VENOUS THROMBOSIS AFTER PANCREAS TRANSPLANTATION - DIAGNOSIS WITH DUPLEX DOPPLER SONOGRAPHY AND SCINTIGRAPHY
    BOISKIN, I
    SANDLER, MP
    FLEISCHER, AC
    NYLANDER, WA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) : 529 - 531
  • [10] ACUTE TORSION OF A WANDERING SPLEEN - DIAGNOSIS BY CT AND DUPLEX DOPPLER AND COLOR FLOW SONOGRAPHY
    NEMCEK, AA
    MILLER, FH
    FITZGERALD, SW
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (02) : 307 - 309