Particulate PCDD/F size distribution and potential deposition in respiratory system from a hazardous waste thermal treatment process

被引:1
|
作者
Lin, Sheng-Lun [1 ]
Tang, Wei [1 ]
Wu, Jhong-Lin [2 ]
Lee, Yen-Yi [3 ,4 ]
Wang, Chih-Lung [3 ,5 ]
Chen, Wei-Hsin [6 ,7 ,8 ]
机构
[1] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
[2] Natl Cheng Kung Univ, Environm Resource & Management Res Ctr, Tainan 70101, Taiwan
[3] Cheng Shiu Univ, Ctr Environm Toxin & Emer contaminant Res, Kaohsiung 83347, Taiwan
[4] Cheng Shiu Univ, Dept Food & Beverage Management, Kaohsiung 83347, Taiwan
[5] Cheng Shiu Univ, Dept Civil Engn & Geomat, Kaohsiung 83347, Taiwan
[6] Natl Cheng Kung Univ, Dept Aeronaut & Astronaut, Tainan 70101, Taiwan
[7] Tunghai Univ, Res Ctr Smart Sustainable Circular Econ, Taichung 407224, Taiwan
[8] Natl Chin Yi Univ Technol, Dept Mech Engn, Taichung 411030, Taiwan
关键词
PCDD/Fs; Scrubber; Cyclone demister; Particle sized distribution; Particle deposition; GAS SHIFT REACTION; PARTICLE DEPOSITION; DIOXINS; PAHS; DECOMPOSITION; TEMPERATURE; SCRUBBERS; FLAMES; SOOT;
D O I
10.1016/j.envres.2022.113806
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The particulate polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) of various sizes produced from the waste incinerators might have different toxicities, deposition characteristics, and potential health effects in the respiratory system, and their total toxicity equivalent (TEQ) concentration has been strictly regulated in recent years. There is a knowledge gap on the effects of air pollution control devices on particle size distributions (PSDs) of PCDD/Fs and their TEQ deposition. A hazardous waste thermal treatment plant equipped with an advanced scrubber, a cyclone demister, and activated carbon adsorption coupled with a baghouse filtration was investigated in this study. An 8-stage impactor was used to collect the particle distribution of PM10 and bounded PCDD/Fs from the gas stream at four sampling points located before and after each control unit. A "TEQ(DE)" index is defined for the toxicity deposition of PM10 -PCDD/F in the respiratory system. The advanced scrubbers significantly reduced the PM10 -PCDD/F levels, especially for those with sizes >= 0.6 and <= 0.4 mu m. Additionally, the cyclone also showed a better performance than the general dry gas treatment but had an efficiency drop with 1.5-4 mu m particles. The PM10-PCDD/F loads in the final adsorption-filtration unit were eased and effectively removed the PM10-PCDD/Fs to sizes <= 0.5 or >= 1.5 mu m. The total TEQ DE was 0.00052 ng WHO-TEQ Nm(-3) and had a peak level of 0.000157 ng WHO-TEQ Nm(-3) at 1.2 mu m. PSDs were more sensitive to the PSDs of PM mass at high PM levels but strongly correlated with the PSDs of "PM10-PCDD/Fs/PM10" at low PM10 loads. Consequently, the advanced control system could effectively remove the PM10-PCDD/Fs and might extend the adsorption-filtration lifetime. However, the PM10-PCDD/Fs <= 0.4 mu m had a higher TEQ deposition rate and should be further considered in emissions and ambient air quality evaluations.
引用
收藏
页数:10
相关论文
共 3 条
  • [1] Ultra-low PCDD/F emissions and their particle size and mass distribution in a hazardous waste treatment system
    Lin, Sheng-Lun
    Wu, Jhong-Lin
    Chen, Wei-Hsin
    Wu, Han
    Tang, Wei
    JOURNAL OF HAZARDOUS MATERIALS, 2022, 423
  • [2] Seasonal distribution and deposition patterns of size-segregated particulate matter in human respiratory system in Central Delhi, India
    Nisha Rani
    Monika J. Kulshrestha
    Air Quality, Atmosphere & Health, 2025, 18 (1) : 179 - 203
  • [3] Effects of a quenching treatment on PCDD/F reduction in the bottom ash of a lab waste incinerator to save the energy and cost incurred from post-thermal treatment
    Lin, Sheng-Lun
    Lee, Kuan-Lin
    Wu, Jhong-Lin
    Cheruiyot, Nicholas Kiprotich
    WASTE MANAGEMENT, 2019, 95 : 316 - 324