Changes in Intra-pelvic Obliquity Angle 0-2 Years After Total Hip Arthroplasty and Its Effects on Leg Length Discrepancy: A Retrospective Study

被引:12
|
作者
Zhang, Yin [1 ]
Cheng, Tao [1 ]
Zhang, Xian-Long [1 ]
机构
[1] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Orthopaed, Shanghai 200233, Peoples R China
关键词
Age Related; Leg Length Discrepancy; Pelvic Obliquity; Prosthesis Orientation; Total Hip Arthroplasty; DEVELOPMENTAL DYSPLASIA; ACETABULAR COMPONENT; TILT; INCLINATION; REPLACEMENT; ORIENTATION; MANAGEMENT; INEQUALITY; SPINE;
D O I
10.4103/0366-6999.156780
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Total hip arthroplasty (THA) is one of the most effective treatments for phase III and IV hip arthrosis. Lower limb length balancing is one of the determining factors of a successful surgery, particularly inpatients with developmental dysplasia of the hip (DDH). The purpose of this study was to evaluate the postoperative change in intra-pelvic obliquity (intra-PO) angle in the coronal plane and its effects on leg length discrepancy (LLD) within 2 years. Methods: A total of 78 patients (70 females, 8 males) were enrolled in this study. All patients were suffering from DDH with varying degrees of LLD. Pelvic plain radiographs were collected before and after the operation. The intra-PO angles were measured 0, 0.5, 1 and 2 years after THA. At the same time, postoperative LLD was measured with blocking test. Results: PO changed significantly in the first year after THA surgery (0 year vs. 0.5 year, P < 0.01; 0.5 year vs. 1 year, P < 0.01), and the changing value of intra-PO angle (APO) slowed down substantially during the first 2 years after THA (0.5 year vs. 0.5-1 year, P < 0.01; 0.5-1 year vs. 1-2 years, P < 0.01). With the change in intra-PO angle, LLD also got narrow within the 1st year (0 year vs. 0.5 year, P < 0.01; 0.5 year vs. 1 year, P < 0.01). Elderly patients had a smaller intra-PO angle reduction (Group A vs. Group B, P = 0.01; Group B vs. Group C, P < 0.01). Conclusions: Intra-PO angle and LLD gap narrowed with time after THA surgery. In particular, elderly patients had smaller change in intra-PO angle.
引用
收藏
页码:1346 / 1350
页数:5
相关论文
共 18 条
  • [1] Changes in Intra-pelvic Obliquity Angle 0–2 Years After Total Hip Arthroplasty and Its Effects on Leg Length Discrepancy: A Retrospective Study
    Zhang Yin
    Cheng Tao
    Zhang Xian-Long
    中华医学杂志英文版, 2015, 128 (10) : 1346 - 1350
  • [2] A large preoperative pelvic oblique angle affects perception of leg length discrepancy after total hip arthroplasty
    Takemoto, Genta
    Osawa, Yusuke
    Seki, Taisuke
    Takegami, Yasuhiko
    Kato, Daisaku
    Okamoto, Masanori
    Iida, Hiroki
    Imagama, Shiro
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2024, 29 (02) : 566 - 573
  • [3] Direction of pelvic obliquity after total hip arthroplasty for dysplastic hip osteoarthritis: a retrospective observational study
    Yokoi, Hiroyuki
    Osawa, Yusuke
    Takegami, Yasuhiko
    Ozawa, Yuto
    Funahashi, Hiroto
    Imagama, Shiro
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [4] Impact of the hip-spine relationship and patient-perceived leg length discrepancy after total hip arthroplasty: A retrospective study
    Omichi, Yasuyuki
    Goto, Tomohiro
    Wada, Keizo
    Tamaki, Yasuaki
    Hamada, Daisuke
    Sairyo, Koichi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2024, 29 (03) : 854 - 860
  • [5] Proximal Femoral Shape Changes the Risk of a Leg Length Discrepancy After Primary Total Hip Arthroplasty
    Lim, Young Wook
    Huddleston, James I., III
    Goodman, Stuart B.
    Maloney, William J.
    Amanatullah, Derek F.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (12): : 3699 - 3703
  • [6] The impact of operative approach and intraoperative imaging on leg length discrepancy and acetabular component angle in total hip arthroplasty: a retrospective cohort study
    Zoe Thompson
    Amir Khoshbin
    Sarah Ward
    Jacqueline Brillantes
    Luana Melo
    James P. Waddell
    Amit Atrey
    International Orthopaedics, 2024, 48 : 473 - 479
  • [7] Preoperative Leg Length Discrepancy &gt;2 cm in the Supine Decubitus Position May Induce Compensatory Pelvic Obliquity in Patients during Total Hip Arthroplasty
    Sun, Xiaoliang
    Qiu, Jiandi
    Jiang, Songli
    Lin, Lan
    Yang, Guojing
    Yang, Shengwu
    Zhang, Lei
    ORTHOPAEDIC SURGERY, 2023, 15 (05) : 1366 - 1374
  • [8] The impact of operative approach and intraoperative imaging on leg length discrepancy and acetabular component angle in total hip arthroplasty: a retrospective cohort study
    Thompson, Zoe
    Khoshbin, Amir
    Ward, Sarah
    Brillantes, Jacqueline
    Melo, Luana
    Waddell, James P.
    Atrey, Amit
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (02) : 473 - 479
  • [9] Hip-Sparing Equalization Procedures for Leg-Length Discrepancy after Total Hip Arthroplasty: A Retrospective Case Series
    Makhdom, Asim M.
    Fragomen, Austin T.
    Rozbruch, S. Robert
    HSS JOURNAL, 2020, 16 (2_SUPPL) : 400 - 407
  • [10] Change in Pelvic Tilt Angle 2 to 4 Years After Total Hip Arthroplasty
    Taki, Naoya
    Mitsugi, Naoto
    Mochida, Yuichi
    Akamatsu, Yasushi
    Saito, Tomoyuki
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 940 - 944