Point Shear Wave Elastography and 2-Dimensional Shear Wave Elastography as a Non-Invasive Method in Differentiating Benign from Malignant Liver Lesions

被引:3
|
作者
Nacheva-Georgieva, Emiliya Lyubomirova [1 ]
Doykov, Daniel Ilianov [1 ]
Andonov, Vladimir Nikolov [1 ]
Doykova, Katya Angelova [2 ]
Tsvetkova, Silviya Bogdanova [2 ]
机构
[1] Med Univ Plovdiv, Dept Internal Dis 2, Sect Gastroenterol, Plovdiv 4000, Bulgaria
[2] Med Univ Plovdiv, Dept Radiol, Plovdiv 4000, Bulgaria
关键词
focal liver lesion; pSWE; 2D-SWE; elastography; TRANSIENT ELASTOGRAPHY; WFUMB GUIDELINES; CLINICAL-USE; REPRODUCIBILITY; FIBROSIS; RECOMMENDATIONS; STIFFNESS; DISEASE;
D O I
10.3390/gastroent13030030
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Non-invasive, ultrasound-based methods for visualizing and measuring tissue elasticity are becoming more and more common in routine daily practice. An accurate diagnosis of malignant and benign tumors is essential for determining the appropriate treatment. Despite the wide use of imaging techniques, the investigation for assessing the elasticity of focal liver lesions and their differentiating is still continuing. Aim: To investigate the value of point shear wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE) for the differential diagnosis of benign and malignant focal liver lesions. Materials and Methods: A total of 125 adult patients were included from the Clinic of Gastroenterology of University Hospital Kaspela, Plovdiv city, Bulgaria, in the period from January 2021 to July 2022. Participants were divided into two groups-with benign (hemangiomas) and malignant focal liver lesions (hepatocellular carcinoma). The group with benign lesions included 63 patients and the group with malignant focal liver lesions (FLLs)-62 patients. Point shear wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE) integrated in the same ultrasound machine (Esaote MyLab (TM) 9Exp) were performed for each lesion. Results: Malignant FLLs have significantly higher stiffness in both pSWE (2.52-4.32 m/s, 90% CI: 2.37 to 2.68, 90% CI: 4.19 to 4.55) and 2d-SWE (2.52-4.43 m/s, 90% CI: 2.31 to 2.65, 90% CI: 4.27 to 4.61). Conclusion: 2D-SWE and pSWE could provide complementary data about FLLs. They enable us to conveniently and easily obtain accurate stiffness information of FLLs.
引用
收藏
页码:296 / 304
页数:9
相关论文
共 50 条
  • [1] Value of Shear Wave Elastography for differentiating benign and malignant renal lesions
    Aydin, Sinem
    Yildiz, Seyma
    Turkmen, Ihsan
    Sharifov, Rasul
    Uysal, Omer
    Gucin, Zuhal
    Armagan, Abdullah
    Kocakoc, Ercan
    [J]. MEDICAL ULTRASONOGRAPHY, 2018, 20 (01) : 21 - 26
  • [2] Comparison of Point Shear Wave Elastography and 2-Dimensional Shear Wave Elastography Values of Liver Metastases from Colorectal Cancer
    Nacheva-Georgieva, Emiliya Lyubomirova
    Doykov, Daniel Ilianov
    Hristov, Bozhidar Krasimirov
    Doykova, Katya Angelova
    Doykov, Mladen Ilianov
    [J]. GASTROENTEROLOGY INSIGHTS, 2023, 14 (03) : 271 - 281
  • [3] Diagnostic value of strain elastography and shear wave elastography in differentiating benign and malignant breast lesions
    Shahzad, Rafia
    Fatima, Ismat
    Anjum, Tooba
    Shahid, Abubaker
    [J]. ANNALS OF SAUDI MEDICINE, 2022, 42 (05) : 319 - 326
  • [4] Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography
    Ji Hyun Youk
    Hye Mi Gweon
    Eun Ju Son
    Jin Chung
    Jeong-Ah Kim
    Eun-kyung Kim
    [J]. European Radiology, 2013, 23 : 1519 - 1527
  • [5] Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography
    Youk, Ji Hyun
    Gweon, Hye Mi
    Son, Eun Ju
    Chung, Jin
    Kim, Jeong-Ah
    Kim, Eun-kyung
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (06) : 1519 - 1527
  • [6] Shear wave elastography-based ultrasomics: differentiating malignant from benign focal liver lesions
    Wei Wang
    Jian-Chao Zhang
    Wen-Shuo Tian
    Li-Da Chen
    Qiao Zheng
    Hang-Tong Hu
    Shan-Shan Wu
    Yu Guo
    Xiao-Yan Xie
    Ming-De Lu
    Ming Kuang
    Long-Zhong Liu
    Si-Min Ruan
    [J]. Abdominal Radiology, 2021, 46 : 237 - 248
  • [7] Shear wave elastography-based ultrasomics: differentiating malignant from benign focal liver lesions
    Wang, Wei
    Zhang, Jian-Chao
    Tian, Wen-Shuo
    Chen, Li-Da
    Zheng, Qiao
    Hu, Hang-Tong
    Wu, Shan-Shan
    Guo, Yu
    Xie, Xiao-Yan
    Lu, Ming-De
    Kuang, Ming
    Liu, Long-Zhong
    Ruan, Si-Min
    [J]. ABDOMINAL RADIOLOGY, 2021, 46 (01) : 237 - 248
  • [8] Elasticity characterization of malignant and benign liver lesions by shear wave elastography
    George, Bony
    Devadas, Krishnadas
    Varghese, Anoop
    Prabhakaran, Arun
    Iqbal, Asif
    Varghese, Jijo
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2019, 34 : 239 - 239
  • [9] A novel two-dimensional quantitative shear wave elastography for differentiating malignant from benign breast lesions
    Tang, Li
    Xu, Hui-Xiong
    Bo, Xiao-Wan
    Liu, Bo-Ji
    Li, Xiao-Long
    Wu, Rong
    Li, Dan-Dan
    Fang, Lin
    Xu, Xiao-Hong
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (07): : 10920 - 10928
  • [10] Value of shear wave elastography with maximal elasticity in differentiating benign and malignant solid focal liver lesions
    Zhang, Hui-Ping
    Gu, Ji-Ying
    Bai, Min
    Li, Fan
    Zhou, Yu-Qing
    Du, Lian-Fang
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2020, 26 (46) : 7416 - 7424