A novel device for preoperative registration and automatic tracking in cranio-maxillofacial image guided surgery

被引:13
|
作者
Zhang, Wenbin [2 ]
Wang, Chenhao [3 ]
Shen, Guofang [2 ]
Wang, Xudong [2 ]
Cai, Ming [2 ]
Gui, Haijun [2 ]
Liu, Yuncai [3 ]
Yang, Danling [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Shanghai Key Lab Stomatol Shanghai, Dent Clin 1,Peoples Hosp 9,, Shanghai 200011, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Key Lab Stomatol, Dept Oral & Maxillofacial Surg, Peoples Hosp 9,Sch Med, Shanghai 200030, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Image Proc & Pattern Recognit, Shanghai 200030, Peoples R China
基金
中国国家自然科学基金;
关键词
Registration; image guided surgery; automatic tracking; cranio-maxillofacial surgery; NAVIGATION; RECONSTRUCTION;
D O I
10.3109/10929088.2012.710251
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Two key issues in image guided surgery are accurate patient-to-image registration and ongoing tracking of the patient's motion. To address these concerns, a novel device for preoperative registration and automatic tracking was designed, and the accuracy attainable with the device was evaluated in experiments with a skull and in a clinical study. Methods: The device consists of a system of four titanium screws and four fluorescent spheres fixed to carbon bars which can be easily mounted on the maxillary dentition splint. Before surgery, CT image data of a skull with the device in place was acquired and registered in a navigation system. The rigidity and reproducibility of positioning of the device were measured in 15 repeated CT acquisitions of the skull with the device in place. The registration accuracy was compared to that obtained using micro-screw markers fixed to the maxillary alveolus. To determine the potential of the device in aiding image guided cranio-maxillofacial surgery, registration accuracy and surgical outcome were assessed. Results: Fifteen tests were performed for CT scanning with no loosening of the splint and device. The arithmetic mean of the standard deviation (SD) ranged from 0.47 mm to 0.70 mm. When the device was used for registration, the mean deviations for the eight anatomical structures investigated ranged from 0.56 mm at the left infra-orbital foramen to 0.96 mm at the right temple. Compared with the method in which titanium screws are fixed to the maxillary alveolus, the target registration error (TRE) obtained using the new device was much less. Using this device, clinical reduction of a zygomatic-orbital-maxillary complex fracture was successfully completed with a registration discrepancy of less than 0.5 mm. Conclusions: By successfully addressing the two key issues of image guided surgery, the device could be considered accurate and potentially useful for assisting in cranio-maxillofacial surgery.
引用
收藏
页码:259 / 267
页数:9
相关论文
共 50 条
  • [1] Application of preoperative registration and automatic tracking technique for image-guided maxillofacial surgery
    Zhang, Wenbin
    Wang, Xudong
    Zhang, Jianfei
    Shen, Guofang
    [J]. COMPUTER ASSISTED SURGERY, 2016, 21 (01): : 137 - 142
  • [2] Effect of fiducial configuration on target registration error in image-guided cranio-maxillofacial surgery
    Zhang, Wenbin
    Wang, Chenhao
    Yu, Hongbo
    Liu, Yuncai
    Shen, Guofang
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2011, 39 (06) : 407 - 411
  • [3] Validation of 3D-laser surface registration for image-guided cranio-maxillofacial surgery
    Hoffmann, J
    Westendorff, C
    Leitner, C
    Bartz, D
    Reinert, S
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2005, 33 (01) : 13 - 18
  • [7] Comparison of different registration methods for navigation in cranio-maxillofacial surgery
    Zinser, M
    Mischkowski, R
    Siessegger, M
    Neugebauer, J
    Kübler, A
    Zöller, JE
    [J]. PERSPECTIVE IN IMAGE-GUIDED SURGERY, 2004, : 19 - 25
  • [8] Comparison of different registration methods for surgical navigation in cranio-maxillofacial surgery
    Luebbers, Heinz-Theo
    Messmer, Peter
    Obwegeser, Joachim Anton
    Zwahlen, Roger Arthur
    Kikinis, Ron
    Graetz, Klaus Wilhelm
    Matthews, Felix
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2008, 36 (02) : 109 - 116
  • [9] Cranio-maxillofacial surgery in Corpus Hippocraticum
    Mylonas, AI
    Tzerbos, FH
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2006, 34 (03) : 129 - 134
  • [10] Oral and cranio-maxillofacial surgery in Byzantium
    Mylonas, Anastassios I.
    Poulakou-Rebelakou, Eleftheria-Fotini
    Androutsos, Georgios I.
    Seggas, Ioannis
    Skouteris, Christos A.
    Papadopoulou, Evangelia Chr
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (02) : 159 - 168