Determination of clozapine, desmethylclozapine and clozapine N-oxide in human plasma by reversed-phase high-performance liquid chromatography with ultraviolet detection

被引:44
|
作者
Avenoso, A
Facciolá, G
Campo, GM
Fazio, A
Spina, E
机构
[1] Univ Messina, Sch Med, Inst Pharmacol, I-98122 Messina, Italy
[2] Univ Messina, Inst Neurol & Neurol Sci, I-98122 Messina, Italy
关键词
clozapine; desmethylclozapine; clozapine N-oxide;
D O I
10.1016/S0378-4347(98)00202-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An isocratic high-performance liquid chromatography (HPLC) method with ultraviolet detection for the simultaneous determination of clozapine and its two major metabolites in human plasma is described. Analytes are concentrated from alkaline plasma by liquid-liquid extraction with n-hexane-isoamyl alcohol (75:25, v/v). The organic phase is back-extracted with 150 mu l of 0.1 M dibasic phosphate (pH 2.2 with 25% H3PO4). Triprolidine is used as internal standard. For the chromatographic separation the mobile phase consisted of acetonitrile-0.06 M phosphate buffer, pH 2.7 with 25% phosphoric acid (48:52, v/v). Analytes are eluted at a flow-rate of 1.0 ml/min, separated on a 250x4.60 mm I.D. analytical column packed with 5 mu m C-6 silica particles, and measured by UV absorbance detection at 254 nm. The separation requires 7 min. Calibration curves for the three analytes are linear within the clinical concentration range. Mean recoveries were 92.7% for clozapine, 82.0% for desmethylclozapine and 70.4% for clozapine N-oxide. C.V. values for intra- and inter-day variabilities were less than or equal to 13.8% at concentrations between 50 and 1000 ng/ml. Accuracy, expressed as percentage error, ranged from -19.8 to 2.8%. The method was specific and sensitive with quantitation limits of 2 ng/ml for both clozapine and desmethylclozapine and 5 ng/ml for clozapine N-oxide. Among various psychotropic drugs and their metabolites, only 2-hydroxydesipramine caused significant interference. The method is applicable to pharmacokinetic studies and therapeutic drug monitoring. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:299 / 308
页数:10
相关论文
共 50 条
  • [1] DETERMINATION OF CLOZAPINE AND DESMETHYLCLOZAPINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    CHUNG, MC
    LIN, SK
    CHANG, WH
    JANN, MW
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (01): : 168 - 173
  • [2] Determination of clozapine, and its metabolites, N-desmethylclozapine and clozapine N-oxide in dog plasma using high-performance liquid chromatography
    Mosier, KE
    Song, JX
    McKay, G
    Hubbard, JW
    Fang, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (02): : 377 - 382
  • [3] Simultaneous determination of clozapine, clozapine N-oxide, N-desmethylclozapine, risperidone, and 9-hydroxyrisperidone in plasma by high performance liquid chromatography with ultraviolet detection
    Shen, YL
    Wu, HL
    Ko, WK
    Wu, SM
    ANALYTICA CHIMICA ACTA, 2002, 460 (02) : 201 - 208
  • [4] Simultaneous determination of clozapine, norclozapine and clozapine-N-oxide in human plasma by high-performance liquid chromatography with ultraviolet detection
    Liu, YY
    van Troostwijk, LJAED
    Guchelaar, HJ
    BIOMEDICAL CHROMATOGRAPHY, 2001, 15 (04) : 280 - 286
  • [5] Assay for quantitation of clozapine and its metabolite N-desmethylclozapine in human plasma by high-performance liquid chromatography with ultraviolet detection
    Edno, L
    Combourieu, I
    Cazenave, M
    Tignol, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (02) : 311 - 318
  • [6] Determination of benflumetol in human plasma by reversed-phase high-performance liquid chromatography with ultraviolet detection
    Zeng, MY
    Lu, ZL
    Yang, SC
    Zhang, M
    Liao, J
    Liu, SL
    Teng, XH
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (02): : 299 - 306
  • [7] Determination of olanzapine in human plasma by reversed-phase high-performance liquid chromatography with ultraviolet detection
    D'Arrigo, Concetta
    Migliardi, Gaetana
    Santoro, Vincenza
    Spina, Edoardo
    THERAPEUTIC DRUG MONITORING, 2006, 28 (03) : 388 - 393
  • [8] THE ASSAY OF CLOZAPINE AND N-DESMETHYLCLOZAPINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LOVDAHL, MJ
    PERRY, PJ
    MILLER, DD
    THERAPEUTIC DRUG MONITORING, 1991, 13 (01) : 69 - 72
  • [9] Clozapine and norclozapine quantification in human plasma by high-performance liquid chromatography with ultraviolet detection
    Illamola, S. M.
    Perez, A. A.
    Morillas, M. G.
    Fresquet, X. S.
    Barreda, F. C.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 525 - 525
  • [10] SENSITIVE METHOD FOR DETERMINATION OF NICORANDIL IN HUMAN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    TANIKAWA, M
    UZU, M
    OHSAWA, Y
    FUKUSHIMA, M
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 617 (01): : 163 - 167