Methodical study of nitrous oxide eddy covariance measurements using quantum cascade laser spectrometery over a Swiss forest

被引:76
|
作者
Eugster, W. [1 ]
Zeyer, K.
Zeeman, M.
Michna, P.
Zingg, A.
Buchmann, N.
Emmenegger, L.
机构
[1] Swiss Fed Inst Technol, Inst Plant Sci, CH-8092 Zurich, Switzerland
[2] Swiss Fed Labs Mat Testing & Res, Empa, CH-8600 Dubendorf, Switzerland
[3] Univ Bern, Inst Geog, CH-3012 Bern, Switzerland
[4] Swiss Fed Inst Forest Snow & Landscape Res, WSL, CH-8903 Birmensdorf, Switzerland
关键词
D O I
10.5194/bg-4-927-2007
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
Nitrous oxide fluxes were measured at the Lageren CarboEurope IP flux site over the multi-species mixed forest dominated by European beech and Norway spruce. Measurements were carried out during a four-week period in October-November 2005 during leaf senescence. Fluxes were measured with a standard ultrasonic anemometer in combination with a quantum cascade laser absorption spectrometer that measured N2O, CO2, and H2O mixing ratios simultaneously at 5 Hz time resolution. To distinguish insignificant fluxes from significant ones it is proposed to use a new approach based on the significance of the correlation coefficient between vertical wind speed and mixing ratio fluctuations. This procedure eliminated roughly 56% of our half-hourly fluxes. Based on the remaining, quality checked N2O fluxes we quantified the mean efflux at 0.8 +/- 0.4 mu mol m(-2) h(-1) (mean +/- standard error). Most of the contribution to the N2O flux occurred during a 6.5-h period starting 4.5 h before each precipitation event. No relation with precipitation amount could be found. Visibility data representing fog density and duration at the site indicate that wetting of the canopy may have as strong an effect on N2O effluxes as does below-ground microbial activity. It is speculated that above-ground N2O production from the senescing leaves at high moisture (fog, drizzle, onset of precipitation event) may be responsible for part of the measured flux.
引用
收藏
页码:927 / 939
页数:13
相关论文
共 34 条
  • [1] Quantum-cascade laser measurements of stratospheric methane and nitrous oxide
    Webster, CR
    Flesch, GJ
    Scott, DC
    Swanson, JE
    May, RD
    Woodward, WS
    Gmachl, C
    Capasso, F
    Sivco, DL
    Baillargeon, JN
    Hutchinson, AL
    Cho, AY
    [J]. APPLIED OPTICS, 2001, 40 (03) : 321 - 326
  • [2] Eddy covariance carbonyl sulfide flux measurements with a quantum cascade laser absorption spectrometer
    Gerdel, Katharina
    Spielmann, Felix Maximilian
    Hammerle, Albin
    Wohlfahrt, Georg
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2017, 10 (09) : 3525 - 3537
  • [3] Measurements of spectral parameters for nitrous oxide near 4.56 μm using a quantum cascade laser
    Li, Fei
    Zeng, Hui
    Wang, Kuanliang
    Zhang, Shaohua
    Yu, Xilong
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2016, 185 : 79 - 85
  • [4] Eddy covariance measurements of CO2 isotopologues with a quantum cascade laser absorption spectrometer
    Sturm, Patrick
    Eugster, Werner
    Knohl, Alexander
    [J]. AGRICULTURAL AND FOREST METEOROLOGY, 2012, 152 : 73 - 82
  • [5] Applicability of a closed-path quantum cascade laser spectrometer for eddy covariance (EC) flux measurements of nitric oxide (NO) over a cropland during a low emission period
    Wang, Kai
    Wang, Dong
    Zheng, Xunhua
    Nelson, David D.
    [J]. AGRICULTURAL AND FOREST METEOROLOGY, 2020, 282
  • [6] In-flight measurements of ambient methane, nitrous oxide and water using a quantum cascade laser based spectrometer
    K.G. Hay
    S. Wright
    G. Duxbury
    N. Langford
    [J]. Applied Physics B, 2008, 90 : 329 - 337
  • [7] In-flight measurements of ambient methane, nitrous oxide and water using a quantum cascade laser based spectrometer
    Hay, K. G.
    Wright, S.
    Duxbury, G.
    Langford, N.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (02): : 329 - 337
  • [8] Applicability of an eddy covariance system based on a close-path quantum cascade laser spectrometer for measuring nitrous oxide fluxes from subtropical vegetable fields
    Wang Dong
    Wang Kai
    Diaz-Pines, Eugenio
    Zheng Xunhua
    Butterbach-Bahl, Klaus
    [J]. ATMOSPHERIC AND OCEANIC SCIENCE LETTERS, 2016, 9 (05) : 381 - 387
  • [9] Applicability of an eddy covariance system based on a close-path quantum cascade laser spectrometer for measuring nitrous oxide fluxes from subtropical vegetable fields
    WANG Dong
    WANG Kai
    Eugenio DíAZ-PINS
    ZHENG Xunhua
    Klaus BUTTERBACH-BAHL
    [J]. Atmospheric and Oceanic Science Letters, 2016, 9 (05) : 381 - 387
  • [10] Simultaneous detection of atmospheric nitrous oxide and carbon monoxide using a quantum cascade laser
    Khan, Amir
    Sun, Kang
    Miller, David J.
    Zondlo, Mark A.
    [J]. SENSING TECHNOLOGIES FOR GLOBAL HEALTH, MILITARY MEDICINE, DISASTER RESPONSE, AND ENVIRONMENTAL MONITORING AND BIOMETRIC TECHNOLOGY FOR HUMAN IDENTIFICATION VIII, 2011, 8029