Early aseptic loosening of a mobile-bearing total knee replacement: A case-control study with retrieval analyses

被引:38
|
作者
Kutzner, Ines [1 ,3 ]
Hallan, Geir [2 ]
Hol, Paul Johan [1 ,2 ]
Furnes, Ove [1 ,2 ]
Gothesen, Oystein [1 ,2 ,6 ]
Figved, Wender [5 ]
Ellison, Peter [1 ,4 ]
机构
[1] Univ Bergen, Dept Clin Med, Bergen, Norway
[2] Haukeland Hosp, Dept Orthopaed Surg, Norwegian Arthroplasty Register, Bergen, Norway
[3] Charite Univ Med Berlin, Julius Wolff Inst, Berlin, Germany
[4] Imperial Coll London, Dept Mech Engn, London, England
[5] Vestre Viken Hosp Trust, Baerum Hosp, Orthoped Dept, Sandvika, Norway
[6] Haugesund Hosp, Haugesund, Norway
关键词
NORWEGIAN ARTHROPLASTY REGISTER; INTERNATIONAL COMPARATIVE-EVALUATION; TIBIAL COMPONENTS; FOLLOW-UP; METAL; PROSTHESES; REVISION; FAILURE; RISK; STABILITY;
D O I
10.1080/17453674.2017.1398012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - Registry-based studies have reported an increased risk of aseptic tibial loosening for the cemented Low Contact Stress (LCS) total knee replacement compared with other cemented designs; however, the reasons for this have not been established. We made a retrieval analysis with the aim of identifying the failure mechanism. Patients and methods - We collected implants, cement, tissue, blood, and radiographs from 32 failed LCS Complete cases. Damage to the tibial baseplate and insert was assessed. Exposure to wear products was quantified in 11 cases through analysis of periprosthetic tissue and blood. Implant alignment and bone cement thickness was compared with a control group of 43 non-revised cases. Results - Loosening of the tibial baseplate was the reason for revision in 25 retrievals, occurring at the implant-cement interface in 16 cases. Polishing was observed on the lower surface of the baseplate and correlated to the level of cobalt, chromium, and zirconium in the blood. No evidence of abnormally high polyethylene wear was present. For each 1mm increase in cement thickness the odds of failure due to aseptic loosening decreased by 61%. Greater varus alignment was associated with a shorter time to failure. The roughness, Ra, of a new LCS baseplate's lower surface was 3.7 (SD 0.7) mu m. Interpretation - Debonding of the tibial component at the implant-cement interface was the predominant cause of tibial aseptic loosening. A thin cement layer may partly explain the poor performance. Furthermore, the comparatively low tibial surface roughness and the lack of a keeled stem may have played a role in the failures observed.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 50 条
  • [11] Early aseptic loosening of primary total knee arthroplasty in patients with osteonecrosis of the knee: A case series
    Baek, Ji-Hoon
    Lee, Su Chan
    Ryu, Suengryol
    Ahn, Hye Sun
    Nam, Chang Hyun
    CLINICAL CASE REPORTS, 2022, 10 (12):
  • [12] Gait analysis and electromyography in fixed- and mobile-bearing total knee replacement: a prospective, comparative study
    Tibesku, Carsten O.
    Daniilidis, Kiriakos
    Skwara, Adrian
    Dierkes, Tobias
    Rosenbaum, Dieter
    Fuchs-Winkelmann, Susanne
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (12) : 2052 - 2059
  • [13] Atraumatic dislocation in mobile-bearing total knee arthroplasty -: Two case reports
    Schuh, A.
    Hoenle, W.
    ZENTRALBLATT FUR CHIRURGIE, 2007, 132 (05): : 460 - 464
  • [14] Navigation Improves the Survival Rate of Mobile-Bearing Total Knee Arthroplasty by Severe Preoperative Coronal Deformity: A Propensity Matched Case-Control Comparative Study
    Jenny, Jean-Yves
    Saragaglia, Dominique
    Bercovy, Michel
    Cazenave, Alain
    Gaillard, Thierry
    Chatain, Frederic
    Jolles-Haeberli, Brigitte
    Rouvillain, Jean-Louis
    JOURNAL OF KNEE SURGERY, 2021, 34 (10) : 1080 - 1084
  • [15] Does a mobile-bearing, high-flexion design increase knee flexion after total knee replacement?
    Nutton, R. W.
    Wade, F. A.
    Coutts, F. J.
    Van der Linden, M. L.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (08): : 1051 - 1057
  • [16] Improved Early Clinical Outcomes of RP/PS Mobile-Bearing Total Knee Arthroplasties
    Kim, Tae Kyun
    Cho, Hyung Joon
    Kang, Yeon Gwi
    Kim, Sung Ju
    Chang, Chong Bum
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (11) : 2901 - 2910
  • [17] Aseptic loosening after total hip arthroplasty and the risk of cardiovascular disease: A nested case-control study
    Rysinska, Agata
    Skoldenberg, Olof
    Garland, Anne
    Rolfson, Ola
    Aspberg, Sara
    Eisler, Thomas
    Garellick, Goran
    Stark, Andreas
    Hailer, Nils
    Gordon, Max
    PLOS ONE, 2018, 13 (11):
  • [18] Radiolucent lines in low-contact-stress mobile-bearing total knee arthroplasty: a blinded and matched case control study
    Patrick Sadoghi
    Andreas Leithner
    Patrick Weber
    Jörg Friesenbichler
    Gerald Gruber
    Norbert Kastner
    Katrin Pohlmann
    Volkmar Jansson
    Bernd Wegener
    BMC Musculoskeletal Disorders, 12
  • [19] Comparison of mobile-bearing and fixed-bearing total knee arthroplasty - A prospective randomized study
    Aglietti, P
    Baldini, A
    Buzzi, R
    Lup, D
    De Luca, L
    JOURNAL OF ARTHROPLASTY, 2005, 20 (02): : 145 - 153
  • [20] Radiolucent lines in low-contact-stress mobile-bearing total knee arthroplasty: a blinded and matched case control study
    Sadoghi, Patrick
    Leithner, Andreas
    Weber, Patrick
    Friesenbichler, Joerg
    Gruber, Gerald
    Kastner, Norbert
    Pohlmann, Katrin
    Jansson, Volkmar
    Wegener, Bernd
    BMC MUSCULOSKELETAL DISORDERS, 2011, 12