Central venous catheters in hemodialysis: to accept recommendations or to stick to own experience

被引:4
|
作者
Stolic, Radojica [1 ]
Trajkovic, Goran [1 ]
Peric, Vladan [1 ]
Jovanovic, Aleksandar [1 ]
Stolic, Dragica [2 ]
Sovtic, Sasa [1 ]
Lazarevic, Tatjana [3 ]
Zivic, Ziva [4 ]
Subaric-Gorgieva, Gordana [1 ]
机构
[1] Sch Med, Pristina Kosovska Mitrov, Serbia
[2] Ctr Hlth, Pristina, Serbia
[3] Ctr Clin, Clin Urol & Nefrol, Kragujevac, Serbia
[4] Ctr Clin, Clin Internal Dis, Kragujevac, Serbia
关键词
renal dialysis; catheterization; central venous; risk assessment; bacterial infections; diagnosis; bacteriological techniques; femoral vein; subclavian vein; jugular veins;
D O I
10.2298/VSP0801021S
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Backgraund/Aim. Hemodialysis catheter, as art integral part of hemodialysis, is a catheter placed into the jugular, subclavian and femoral vein. The most common catheter-related complications are infections and thrombosis. The aim of the Study, was to analyze the prevalence of complications associated with differently inserted central-vein catheters for hemodialysis. Methods. The study was organized as a prospective examination during the period from December 2003 to November 2006, and included all patients who needed an active deputation by hemodialysis, hospitalized at the Clinical Center Kragujevac. The subject of the study were 464 central-vein catheters inserted during the mentioned period and there were recorded all complications related to the placement and usage of catheters. Results. The largest percent of inserted catheters was into the femoral vein - 403 (86.8%), significantly less into the jugular vein - 42 (9.2%), while into the subclavian vein there were placed only 19 catheters (4%). The average of femoral catheter functioning was 17 catheter days, in jugular catheters it was 17.3 days while the subclavian catheters had an average rate of functioning of 25.9 catheter days; there was found a statistically significant difference regarding the duration of functioning (P = 0.03). By microbe colonization of smear culture of the skin at the catheter insertion site, in clinically present suspicion of catheter infection, there was obtained a positive finding in 5.5% of catheters placed into the femoral vein and 7.1% of catheters stilled into the jugular vein, of which Staphylococcus aureus was the most important bacterial type, without statistically significant difference (p = 0.51). Haemoculture, done when there was a suspicion of bacteriemia, was positive in 3.7% of the patients with femoral and 4.8% with jugular catheters; lococcus aureus was the most common bacteria type, but there was no statistically significant difference (P = 6.65). Colonizing the smears of the cut catheter tops, there was found a positive finding in 8.9% of femoral and 4.7% of jugular catheters in which the mentioned type of staphylococcal bacteria was prevalent, without statistically significant difference (p = 0.82). In 77% of femoral, 71.4% of jugular and 68.4% of subclavian catheters, there were no complications associated with insertion and manipulation of catheters for hemodialysis and the difference was at the limits of statistical significance (p = 0.06). Conclusion. Unconvincing rate of infections and a smaller percent of serious complications associated with the placement and use of central vein catheters instilled into the femoral vein, indicate that personal experience is sufficient recommendation to convince us that femoral vein does not represent a region with an increased risk for insertion of hemodialysis catheters.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [1] CENTRAL VENOUS HEMODIALYSIS CATHETERS
    SYNHAVSKY, A
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 21 (04) : 454 - 454
  • [2] COMPLICATIONS OF CENTRAL VENOUS CATHETERS FOR HEMODIALYSIS
    REDDIG, J
    WALKER, G
    TWITTENHOFF, WD
    BRITTINGER, WD
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1990, 19 (02) : 69 - 74
  • [3] HEMODIALYSIS TUNNELED CENTRAL VENOUS CATHETERS: FIVE YEARS SINGLE CENTER EXPERIENCE
    Gerasimovska, Vesna
    Gerasimovska-Kitanovska, Biljana
    Sikole, Aleksandar
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [4] Optimal management of central venous catheters for hemodialysis
    Canaud, Bernard
    Chenine, Leila
    Henriet, Delphine
    Leray, Helene
    HEMODIALYSIS: FROM BASIC RESEARCH TO CLINICAL TRIALS, 2008, 161 : 39 - 47
  • [5] Central Venous Catheters in Hemodialysis: A Reasonable Alternative?
    Buckenmayer, Anna
    Moller, Bianca
    Ostermaier, Claudia
    Hoyer, Joachim
    Haas, Christian S.
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2022, 33 (11): : 126 - 126
  • [6] Monitoring of permanent central venous hemodialysis catheters
    Bosc, JY
    Martin, K
    Leray-Moragues, H
    Canaud, B
    NEPHROLOGIE, 2001, 22 (08): : 413 - 415
  • [7] CENTRAL CATHETERS FOR HEMODIALYSIS - A 6 MONTH EXPERIENCE OF 103 CATHETERS
    QUEIROS, J
    CABRITA, A
    MAXIMINO, J
    LOBATO, L
    SILVA, M
    XAVIER, E
    NEPHROLOGIE, 1994, 15 (02): : 113 - 115
  • [8] Cuffed central venous hemodialysis catheters and adequacy of dialysis
    Athirakul, K
    Conlon, P
    Schwab, S
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A0785 - A0785
  • [9] Central Venous Catheters for Hemodialysis-the Myth and the Evidence
    Sohail, Mohammad Ahsan
    Vachharajani, Tushar J.
    Anvari, Evamaria
    KIDNEY INTERNATIONAL REPORTS, 2021, 6 (12): : 2958 - 2968
  • [10] A SURVEY OF HEMODIALYSIS PRACTICE PATTERNS IN CANADA FOR HEMODIALYSIS CENTRAL VENOUS CATHETERS
    Kosa, S.
    Lok, C.
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2013, 61 (04) : A56 - A56