Capillary optics for micro x-ray fluorescence analysis

被引:42
|
作者
Bjeoumikhov, A
Langhoff, N
Bjeoumikhova, S
Wedell, R
机构
[1] IfG Inst Geraetebau GmbH, D-12489 Berlin, Germany
[2] Bundesanstalt Mat Forsch & Pruefung, D-12200 Berlin, Germany
[3] IAP Inst Angew Photon EV, D-12489 Berlin, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2005年 / 76卷 / 06期
关键词
D O I
10.1063/1.1938847
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Practically achieved parameters of capillary optics are presented. A micro x-ray fluorescence (XRF) arrangement was realized by using a microfocus x-ray tube and a capillary optic. Several examples for application of micro XRF are given. It was shown that polycapillary lenses free of the "halo effect" well suited for micro XRF of heavy elements can be manufactured. Limits of opportunities for micro XRF applications and further development for micro XRF by using capillary optics are analyzed. (c) 2005 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Determination of X-ray excitation spectra in micro X-ray fluorescence spectrometry with capillary optics
    Perez, R. D.
    Sosa, C.
    Sbarato, V.
    Leani, J.
    Sanchez, H. J.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 117 : 23 - 28
  • [2] Fundamental characteristics of hybrid X-ray focusing optics for micro X-ray fluorescence analysis
    Komatani, Shintaro
    Nakamachi, Kazuo
    Nakano, Kazuhiko
    Ohzawa, Sumito
    Uchihara, Hiroshi
    Bando, Atsushi
    Tsuji, Kouichi
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 260 - 263
  • [3] X-ray micro-imaging by capillary optics
    Hampai, Dariush
    Dabagov, Sultan B.
    Cappuccio, Giorgio
    Cibin, Giannantonio
    Sessa, Vito
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (11-12) : 1180 - 1184
  • [4] Performance of assembled X-ray optics consisted of a polycapillary X-ray optics and a monocapillary X-ray optics for micro X-ray fluorescence spectrometry
    Sun, Xuepeng
    Zhang, Xiaoyun
    Wang, Yabing
    Shao, Shangkun
    Li, Yufei
    Peng, Shiqi
    Liu, Zhiguo
    Sun, Tianxi
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 165
  • [5] Capillary optics and their use in x-ray analysis
    Kumakhov, MA
    [J]. X-RAY SPECTROMETRY, 2000, 29 (05) : 343 - 348
  • [6] CAPILLARY OPTICS BASED X-RAY MICRO-IMAGING ELEMENTAL ANALYSIS
    Hampai, D.
    Dabagov, S. B.
    Cappuccio, G.
    Longoni, A.
    Frizzi, T.
    Cibin, G.
    [J]. CHARGED AND NEUTRAL PARTICLES CHANNELING PHENOMENA, CHANNELING 2008, 2010, 30 : 775 - 785
  • [7] Performances of capillary X-ray optics for confocal three-dimensional micro-X-ray fluorescence technology
    Sun, Tianxi
    Liu, Zhiguo
    Li, Yude
    Zhu, Guanghua
    Lin, Xiaoyan
    Luo, Ping
    Pan, Qiuli
    Liu, Hui
    Teng, Yuepeng
    Yang, Ke
    Ding, Xunliang
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 606 (03): : 829 - 832
  • [8] A micro X-ray fluorescence analysis method using polycapillary X-ray optics and grazing exit geometry
    Yang, Jun
    Tsuji, Kouichi
    Lin, Xiaoyan
    Han, Dongyan
    Ding, Xunliang
    [J]. THIN SOLID FILMS, 2009, 517 (11) : 3357 - 3361
  • [9] Micro x-ray fluorescence analysis
    Gilfrich, J
    [J]. X-RAY SPECTROMETRY, 1997, 26 (03) : 95 - 95
  • [10] X-RAY OPTICS OF FLUORESCENCE ANALYSIS INSTRUMENTS
    PARRISH, W
    LOWITZSCH, K
    SPIELBERG, N
    [J]. SPECTROCHIMICA ACTA, 1956, 8 (02): : 112 - 113