Accumulation and fate of microorganisms and microspheres in biofilms formed in a pilot-scale water distribution system

被引:61
|
作者
Långmark, J
Storey, MV
Ashbolt, NJ
Stenström, TA
机构
[1] Swedish Inst Infect Dis Control, Dept Parasitol Mycol & Water Microbiol, SE-17182 Solna, Sweden
[2] Univ New S Wales, Ctr Water & Waste Technol, Sydney, NSW, Australia
关键词
D O I
10.1128/AEM.71.2.706-712.2005
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The accumulation and fate of model microbial "pathogens" within a drinking-water distribution system was investigated in naturally grown biofilms formed in a novel pilot-scale water distribution system provided with chlorinated and UV-treated water. Biofilms were exposed to 1-mum hydrophilic and hydrophobic microspheres, Salmonella bacteriophages 2813, and Legionella pneumophila bacteria, and their fate was monitored over a 38-day period. The accumulation of model pathogens was generally independent of the biofilm cell density and was shown to be dependent on particle surface properties, where hydrophilic spheres accumulated to a larger extent than hydrophobic ones. A higher accumulation of culturable legionellae was measured in the chlorinated system compared to the UV-treated system with increasing residence time. The fate of spheres and fluorescence in situ hybridization-positive legionellae was similar and independent of the primary disinfectant applied and water residence time. The more rapid loss of culturable legionellae compared to the fluorescence in situ hybridization-positive legionellae was attributed to a loss in culturability rather than physical desorption. Loss of bacteriophage 2813 plaque-forming ability together with erosion may have affected their fate within biofilms in the pilot-scale distribution system. The current study has demonstrated that desorption was one of the primary mechanisms affecting the loss of microspberes, legionellae, and bacteriophage from biofilms within a pilot-scale distribution system as well as disinfection and biological grazing. In general, two primary disinfection regimens (chlorination and UV treatment) were not shown to have a measurable impact on the accumulation and fate of model microbial pathogens within a water distribution system.
引用
收藏
页码:706 / 712
页数:7
相关论文
共 50 条
  • [1] Fate and distribution of arsenic in a process-designed pilot-scale constructed wetland treatment system
    Schwindaman, Jeffrey P.
    Castle, James W.
    Rodgers, John H., Jr.
    ECOLOGICAL ENGINEERING, 2014, 68 : 251 - 259
  • [2] Pilot-scale ozone inactivation of Cryptosporidium and other microorganisms in natural water
    Owens, JH
    Miltner, RJ
    Rice, EW
    Johnson, CH
    Dahling, DR
    Schaefer, FW
    Shukairy, HM
    OZONE-SCIENCE & ENGINEERING, 2000, 22 (05) : 501 - 517
  • [3] Degradation of chloramphenicol by chlorine and chlorine dioxide in a pilot-scale water distribution system
    Li, Cong
    Luo, Feng
    Duan, Haojie
    Dong, Feilong
    Chen, Xiaoyang
    Feng, Mingbao
    Zhang, Zuoran
    Cizmas, Leslie
    Sharma, Virender K.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 211 : 564 - 570
  • [4] A general framework of chlorine decay modeling at a pilot-scale water distribution system
    Kim, Hyunjun
    Koo, Jayong
    Kim, Sanghyun
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2015, 64 (05): : 543 - 557
  • [5] Pilot-scale drinking water distribution system to study water quality changes during transport
    Garcia-Timermans, Cristina
    Malfroot, Bram
    Dierendonck, Cameron
    Mol, Zoe
    Pluym, Thomas
    Waegenaar, Fien
    Arends, Jan B. A.
    Demeestere, Kristof
    Walgraeve, Christophe
    Boon, Nico
    De Gusseme, Bart
    NPJ CLEAN WATER, 2023, 6 (01)
  • [6] Pilot-scale drinking water distribution system to study water quality changes during transport
    Cristina García-Timermans
    Bram Malfroot
    Cameron Dierendonck
    Zoë Mol
    Thomas Pluym
    Fien Waegenaar
    Jan B. A. Arends
    Kristof Demeestere
    Christophe Walgraeve
    Nico Boon
    Bart De Gusseme
    npj Clean Water, 6
  • [7] Fate of selected RCRA compounds in a pilot-scale activated sludge system
    Bhattacharya, SK
    Madura, RL
    Dobbs, RA
    Angara, RVR
    Tabak, H
    WATER ENVIRONMENT RESEARCH, 1996, 68 (03) : 260 - 269
  • [9] Chlorine decay and THMs formation models based on pilot-scale water distribution system
    Li, Cong
    Guo, Shiwen
    Zhang, Tuqiao
    Yu, Jieze
    Mao, Xinwei
    Zhang, Kejia
    Zhang, K. (zhangkj@zju.edu.cn), 1600, Central South University of Technology (44): : 5160 - 5164
  • [10] Chlorination contributes to multi-antibiotic resistance in a pilot-scale water distribution system
    Li, Jinmei
    Zhang, Shuting
    Guo, Lizheng
    Chen, Lihua
    Yu, Zhisheng
    WATER SUPPLY, 2021, 21 (08) : 4369 - 4381