The effect of human blood on the setting and surface micro-hardness of calcium silicate cements

被引:10
|
作者
Song, Minju [1 ]
Yue, Wonyoung [2 ,3 ]
Kim, Soyeon [4 ]
Kim, Wooksung [4 ]
Kim, Yaelim [4 ]
Kim, Jeong-Woong [4 ]
Kim, Euiseong [2 ,3 ]
机构
[1] Univ Calif Los Angeles, Sch Dent, Div Constitut & Regenerat Sci, Sect Restorat Dent, Los Angeles, CA 90024 USA
[2] Yonsei Univ, Coll Dent, Dept Conservat Dent, Microscope Ctr, 50 Yonsei Ro, Seoul 120752, South Korea
[3] Yonsei Univ, Coll Dent, Oral Sci Res Ctr, 50 Yonsei Ro, Seoul 120752, South Korea
[4] Yonsei Univ, Coll Dent, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Human blood; Calcium silicate cements; Micro-hardness; Mineral trioxide aggregate; RetroMTA; MINERAL TRIOXIDE AGGREGATE; END FILLING MATERIALS; FETAL BOVINE SERUM; RETENTION CHARACTERISTICS; CLINICAL-APPLICATIONS; COMPRESSIVE STRENGTH; HYDRATION BEHAVIOR; SEALING ABILITY; IN-VITRO; MICROSTRUCTURE;
D O I
10.1007/s00784-015-1693-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of the present study was to evaluate the effects of human blood on the setting and microhardness of calcium silicate cements. Three types of silicate-based cements were used: ProRoot MTA (PMTA), OrthoMTA (OMTA), and RetroMTA (RMTA). Mixed cement was placed into polyethylene molds with lengths of 2 and 4 mm. After storage for 4 days under three different storage conditions, i.e., saline, saline after 5 min of human blood, and human blood, the polyethylene molds were removed. With the specimens set, the surface microhardness was measured using a Vickers microhardness tester, crystalline structure was analyzed with X-ray diffraction (XRD), and the surface characteristics were examined with scanning electron microscopy (SEM). All specimens of 4 mm in length were set with all materials, and the blood groups exhibited lower microhardnesses than did the saline groups (p < 0.05). Among the 2-mm specimens that were stored in blood, the numbers of specimens that set were significantly different across the materials (p < 0.001). Regarding the microhardnesses of the RMTA and OMTA groups, there were no significant differences between storage conditions. For the PMTA group, only one specimen that was set in the blood group exhibited reduced microhardness. XRD showed changes of crystalline structure in the PMTA and OMTA blood group, whereas RMTA did not. SEM analysis revealed more rounded and homogeneous structures and demonstrated a clear lack of acicular or needle-like crystals in the PMTA and OMTA blood groups, while RMTA did not reveal substantial differences between the saline- and blood-stored groups. Blood contamination detrimentally affected the surface microhardnesses of all materials; furthermore, among the 2-mm specimens, blood contamination interfered with normal setting. Therefore, RMTA might be a more suitable choice when blood contamination is unavoidable due to limited depth. Clinical relevance RetroMTA might be a more suitable choice in situations in which blood contamination is unavoidable.
引用
收藏
页码:1997 / 2005
页数:9
相关论文
共 50 条
  • [41] Variation of surface roughness, micro-hardness and friction behaviour during sheet-metal forming
    Trzepiecinski, Tomasz
    Bochnowski, Wojciech
    Witek, Lucjan
    INTERNATIONAL JOURNAL OF SURFACE SCIENCE AND ENGINEERING, 2018, 12 (02) : 119 - 136
  • [42] Effect of the calcium to phosphorus ratio on the setting properties of calcium phosphate bone cements
    Vlad, M. D.
    Gomez, S.
    Barraco, M.
    Lopez, J.
    Fernandez, E.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2012, 23 (09) : 2081 - 2090
  • [43] Effect of Saliva and Blood Contamination on the Bi-Axial Flexural Strength and Setting Time of Two Calcium-Silicate Based Cements: Portland Cement and Biodentine
    Alhodiry, W.
    Lyons, M. F.
    Chadwick, R. G.
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2014, 22 (01): : 20 - 23
  • [44] Effect of temperature and immersion on the setting of some calcium phosphate cements
    F. C. M. Driessens
    M. G. Boltong
    E. A. P. De Maeyer
    R. M. H. Verbeeck
    R. Wenz
    Journal of Materials Science: Materials in Medicine, 2000, 11 : 453 - 457
  • [45] Effect of the calcium to phosphorus ratio on the setting properties of calcium phosphate bone cements
    M. D. Vlad
    S. Gómez
    M. Barracó
    J. López
    E. Fernández
    Journal of Materials Science: Materials in Medicine, 2012, 23 : 2081 - 2090
  • [46] Effect of temperature and immersion on the setting of some calcium phosphate cements
    Driessens, FCM
    Boltong, MG
    De Maeyer, EAP
    Verbeeck, RMH
    Wenz, R
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2000, 11 (07) : 453 - 457
  • [47] Effects of curing protocol and storage time on the micro-hardness of resin cements used to lute fiber-reinforced resin posts
    Ramos, Marcelo Barbosa
    Pegoraro, Thiago Amadei
    Pegoraro, Luiz Fernando
    Carvalho, Ricardo Marins
    JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (05) : 556 - 562
  • [48] Surface properties of calcium phosphate particles for self setting bone cements
    Gbureck, U
    Probst, J
    Thull, R
    BIOMOLECULAR ENGINEERING, 2002, 19 (2-6): : 51 - 55
  • [49] Effect of immersion time of restorative glass ionomer cements and immersion duration in calcium chloride solution on surface hardness
    Shiozawa, Maho
    Takahashi, Hidekazu
    Iwasaki, Naohiko
    Wada, Takahiro
    Uo, Motohiro
    DENTAL MATERIALS, 2014, 30 (12) : E377 - E383
  • [50] The Effect of Chitosan Nanoparticle as A Final Irrigation Solution on The Smear Layer Removal, Micro-hardness and Surface Roughness of Root Canal Dentin
    Ratih, Diatri Nari
    Enggardipta, Raras Ajeng
    Kartikaningtyas, Aqilla Tiara
    OPEN DENTISTRY JOURNAL, 2020, 14 : 19 - 26